Laserfiche WebLink
SLABS ON GRADE <br /> All slabs on grade, unless otherwise noted, shall be 4" thick with 6x6-W1.4xW1.4 WWF centered <br /> in slab. <br /> REINFORCED CONCRETE BLOCK WALLS <br /> See plans for locations of reinforced wal�s. When one bar is in a single core place in center, <br /> unless noted otherwise. When two bars are in a single core, place one near each face. Fill block <br /> core at verticai steel with 3,000 p.s.i. grout, rodded or vibrated in place. Do not rod with <br /> permanent reinforcing bars. Wall construction shall not exceed heights of 4'-0" before placement <br /> of core grout unless cleanout holes are provided at the bottom of each grout lift, then a maximum <br /> height of 8'-0" before placement of grout. Vertical steel shall be continuous with a 30 diameter <br /> lap in column piers and 40 diameter lap at all other splices unless noted. Provide horizontal joint <br /> reinforcing place every 2�d course. No. 9 gage side rods and no. 9 gage cross rods. Hollow unit <br /> concrete masonry shall be ASTM C90 grade N. <br /> Mortar and grout shall be per ASTM C-270: Type M or S for below grade and exterior masonry, <br /> type N for all interior above grade masonry. <br /> MASONRY LINTELS <br /> All opening in brick faced or brick walls not specifically indicated to have other types of linteis <br /> shall have the following: One L3'/2x3'/zx5/16" angle for each nominal 4" of masonry to a maximum <br /> span of 5'-0". One L6x3'/2x3/8" angle for each nominal 4" of masonry to a maximum span of 10'- <br /> 0". <br /> DIMENSION LUMBER <br /> Dimension lumber shall be No. 2 hem Fir or equal for joists, beams and headers. Wail studs shall <br /> be Stud Grade SPF or equal. Spacing of bridging for joists shall not exceed 8'-0". Wood lintels <br /> and headers shali have a full 1'/z" length of bearing at each end unless notes otherwise. Double <br /> all joists under parallel partitions. All beams and joists not bearing on supporting members shail <br /> be framed with "Simpson Strong-Tie"joist hangers or equal. Interior walls to have 2x4 studs at <br /> 16" on center. Exterior walls to have 2x6 studs at 16" on center. Wood joists shall bear the fuli <br /> width of supporting members (stud wall, beams, etc.) unless otherwise noted. Wood beams <br /> made of 2 or more 2x's shall be bolted together with 3/8" diameter through bolts at 2'-0" on center <br /> or equivalent spikes. Sill plates to be bolted to foundation walls with '/z" diameter anchor bolts at <br /> 4'-0" on center maximum to extend 15" minimum into grouted masonry. Each sill plate to have a <br /> minimum of 2 bolts with one bolt located within 12" of each end of each piece. Nailing to be in <br /> accordance with Table 2304.9.1 of the I.B.C. <br /> LVL WOOD MEMBERS <br /> LVL members noted on drawings are laminated veneer lumber as manufactured by the Trus-Joist <br /> MacMillan. Equivalent at contractor's option. Sizes shown on plan are actual size. <br /> Fb = 2,600 p.s.i., E = 1,900,000 p.s.i. <br /> PSL WOOD MEMBERS <br /> PSL members noted on drawings are parallel strand lumber as manufactured by the Trus-Joist <br /> MacMillan. Equivalent at contractor's option. Sizes shown on plan are actual size. <br /> Fb = 2,400 p.s.i., E = 1,800,000 p.s.i. <br />