My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-00299 - new septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2880 Fox Street - 04-117-23-31-0011
>
Septic
>
2010-00299 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:11:08 PM
Creation date
11/14/2016 3:13:00 PM
Metadata
Fields
Template:
x Address Old
House Number
2880
Street Name
Fox
Street Type
Street
Address
2880 Fox St
Document Type
Septic
PIN
0411723310011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.. ...__ ._ ..,._.._ <br /> . ._,.. . _ ,_...,...���STP"_P�T S�t�CtTarr�#�es' <br /> ....._�__._.,_� ,...__�---., ._.. _..... <br /> �.�._........__....._. . ,_.: <br /> UNIVERSITY <br /> � Minnesota Pollution Worksheet OF MINNESOTA <br /> Control A enc <br /> 1. PUMP CAPACITY <br /> A. Pumping to Gravity or Pressure Distribution: O Gra�iry OO Pmssure-� 2 <br /> 1. If pumping to gravity enter the gallon per minute of the pump: �GPM <br /> 2. If pumping to pressure,is the pump for the treatment system or the collection system: <br /> �Treatrnent System �Coilection System <br /> 2 <br /> 3. If pumping to a pressurized treatment system,what part or type of system: <br /> ❑Soil Treatment Unit ❑Media Filter ❑Other <br /> 4. It pumping to a pressurized distnbution system: 29.0 GPM <br /> (Line 11 of Preswre Distribution or Line f0 of Non-Level or enter i f Coilxtion System) <br /> 2. HEAD REQUIREMENTS <br /> oi hexmentsystem <br /> 3. Elevation Difference �ft &point of diuharge <br /> '.d <br /> between pump and point of discharge: <br /> s�H e�� <br /> NOTE:IFsystem is an individua!wbsurface sewoge treatment __ <br /> system,comp(ete steps 4-9. lf system is a Co(lecfion System, ��a� m Ekwation%�,' <br /> skip steps 4,5, 7 and 8 and go to Step 10. __ d�rse`e"`e <br /> �. _ <br /> 4. Distribution Head loss �ft ��,�,� :,, ----------------------------- -------------� <br /> 5. Additional Head Loss: �ft(due to special equipment,etc.) <br /> Distribution tlead 1_oss Fnctwn Loss�n P asfic P�pe per 100 <br /> Gravity Distribution = Oft C=130 <br /> Nominal Pipe Diameter <br /> Pressure Distribution based on Minimum Average Head FIOW Rdte <br /> Value on Pressure Distribution Worksheet: GPM 1 1�/a 13"z 2 3 <br /> Minimum Avera e Head Distribution Head Loss 10 9.11 3.Q8 1.27 0.31 -- <br /> 1ft 5ft <br /> zft 6ft �2 12.77 4.31 1.78 0.44 --- <br /> 5ft �oft 14 16.99 5.74 2.36 0.58 --- <br /> 16 --- 7.35 3.03 0.75 0.10 <br /> 6. A_Supply Pipe Diameter: 2.0 in 18 -- 9.14 3.76 0.93 0.'13 <br /> B.Supply Pipe Length: 135 ft 2� --- 11.11 4.58 1.13 0.16 <br /> 25 -- 16.79 6.92 1.71 0.24 <br /> 7, Based on Friction Loss in Plastic Pipe per 100R from Table I: 30 --- -- 9.69 2.39 0.33 <br /> Friction Loss= 2.23 ft per 100ft of pipe 35 --- -- 12.90 3.18 0.44 <br /> 40 -_- � 16.52 4.07 0.57 <br /> g, Determine Equivolent Pipe Length from pump discharge to soit dispersal 45 --- - --- 5.07 0.70 <br /> area dixharge point. Estimate by adding 25%to supply pipe length for <br /> fitting loss. Supply Pipe Length(5.8) X 1.25=Equivoient Pipe Length 50 --- -- --- 6.16 0.86 <br /> 55 -- -- --- 7.35 1.02 <br /> 135 ft X t.25 = 168.8 ft 60 --- --- --- 8.63 1.20 <br /> 9, Calculate Supp(y F�iction Loss by multiplying Friction Loss Per f00ft (Line 6)by 65 --- --- -- 10.01 1.38 <br /> 70 --- --- --- 11.48 1.60 <br /> Supply Fridion Loss= <br /> 2.23 ft per 100ft X 168.8 ft � 100 = 3.8 ft <br />
The URL can be used to link to this page
Your browser does not support the video tag.