2010-00299 - new septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2880 Fox Street - 04-117-23-31-0011
>
Septic
>
2010-00299 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:11:08 PM
Creation date
11/14/2016 3:13:00 PM
Metadata
Fields
Template:
x Address Old
House Number
2880
Street Name
Fox
Street Type
Street
Address
2880 Fox St
Document Type
Septic
PIN
0411723310011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � � OSTP Pressure Distribution <br /> UNIVERSITY <br /> Minnesota Pollution Design Worksheet OF MINNESOTA . <br /> Co�trol Agency <br /> 1. Select Number o Per porated Latera(s in stem/zone: � Geotextile <br /> f ! � �1psplp��Ipjblqp0��o0z Minimum�o� OapoBpapoO <br /> (2 feet is minimum and 3 feet is mmcimum spacing) oc !.'pertorations spaced 3'apart �c3 2"o(rock� M1p���� <br /> 2. Select Per oration 5 cin : 3.0 ft �< ����� � � 1z" <br /> f PQ � o�o Cuo 0 0`Cao 0 0 0 0 0 <br /> �� �' t��._ , a�' �'�'�K°�' <br /> DaqrpoC7pOBOeDo�eD�0av,0o�✓DoUr 9�.co��f Vroc-k-t�RDn�a�,Do�Do�O���ao,D��Da�Do <br /> od�d�0'�O`p�p0`�q0�0'q� L�'O°-c�O�O�Q0�0'�O'nU0°��O' <br /> 3. Select Perforotion Diameter Size 1/4 inch <br /> Perforation sizing:'/a"to'/." <br /> Perforation s acin :2'to 3' <br /> 4. Length of Laterals =Media Bed Length -2 Feet. Perforation can not be c(oser then 1 foot from edge. <br /> 38 - 2ft = 36 ft <br /> 5• Determine the Number of Perforation Spaces. Divide the Length of Latera(s (Line 4)by the Perforation Spacing (Line 2)and <br /> round down to the nearest whole number. <br /> Number of Perforation Spnces = 36 ft .- �ft = 12 Spaces <br /> 6. Number of Perforations per Lotero( is equal to 1.0 plus the Number of Perforation Spaces (Line 5). <br /> Perforations Per Lateral = 12 Spaces + i = 13 Perfs. Per Lateral <br /> Check Table i to verifty the number of perforations per(aterai guarQntees less than a ]0%discharge variation. The va(ue is double if <br /> the a center manifold is used. <br /> 7. Tota(Number of Perforations equals the Number of Perforations per Laterat (Line 6)multiplied by the Number of <br /> Perforated Latera(s (Line 1). <br /> 13 Perf. Per Lateral X �Number of Perf. Laterals = 39 Total Number of Perf. <br /> 8. Calculate the Square Feet per Perforation. Recommended va(ue is 4-10 ft Z per perforation. �,Qatl�,aw,�c�PM� <br /> Does not app/y to At-Grades P�raan�a�«� <br /> Bed Areo = Bed Width (ft)X Bed Length(ft) "�d�`� ''• ''�• ''°_ ''. <br /> �.o• o.�a o.�i a.ss o.�a <br /> 10 ft X 38 ft = 380 ftz +•5 o.0 o.5, Q69 0.9 <br /> Z,p� 0.26 0.59 0.80 1.04 <br /> 25 0.29 0.65 0.89 7.17 <br /> Square Foot per Perforation =Bed Areo divided by the Totat Number of Perforations (Line 7). '•° o.3z o.�z o.so ,.z8 <br /> a.o 0.3� o.a3 �.0 t.a� <br /> 5.0` 0.47 0.93 1.26 1.65 <br /> 380 ftZ : 39 perforations = 9.7 ftZ/perforations ,,m� ��d�^�h a,d J/76 inch perforatioru on <br /> ����� <br /> 1/8 inch peAwatlua on dweilirgs and for <br /> 9. Select Minimum Average Head: 1.0 ft ���� olher establishments <br /> 1/4 inch and 3/16 4xh peforatbru on MSTS <br /> 5 feet 1/S inch pertoraHau on MSTS <br /> 10. Select Perforation Discharge (GPM)based on Table III: 0.74 GPM per Perforation <br /> 11. Determine required F(ow Rate by multiplying the Total Number of Perforations (Line 7)by the Perforation Discharge (Line 10). <br /> 39 Perforations X 0.74 GPM per Perforation = 29 GPM <br /> 12. Select Type of Mnnifold Connection (End or Center): �end ❑Center <br />