My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-01069 - new mound septic
Orono
>
Property Files
>
Street Address
>
F
>
Fox Street
>
2720 Fox Street - 04-117-23-42-0004
>
Septic
>
2010-01069 - new mound septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:13:38 PM
Creation date
11/14/2016 2:06:31 PM
Metadata
Fields
Template:
x Address Old
House Number
2720
Street Name
Fox
Street Type
Street
Address
2720 Fox St
Document Type
Septic
PIN
0411723420004
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
University of Minnesota Trench and Bed Worksheet <br /> All boxed rectangles must be entered,the rest will be calculated. <br /> 1. Flow o,,s,n <br /> A. Estimated Flow 450 gpd(Fig.A-1) 3��� <br /> TRCATMlNT <br /> stimate ewage ows in P"O°""" ��� <br /> Number of Class <br /> Bedrooms I II III IV <br /> 2 300 225 180 60%of <br /> 3 450 300 218 the ump an c inimum izmg <br /> 4 600 375 256 values 500 gallons or 100%of Average <br /> 5 750 450 294 in the Design Flow(A-1)or duai <br /> 6 900 525 332 Ciass I, aitematin um s stem <br /> 7 1050 600 370 II or II <br /> 8 1200 675 408 columns <br /> 2. Minimum Septic Tank Capacity <br /> B. Septic tank capacity(Fig C-1) 2000 Galions Number of compartments� <br /> C. Effluent filter(yes/no) recommended <br /> C-1 Minimum Septic Tank Capaci in Gallons <br /> Capacity with GD <br /> Number of Minimum Capacity with and pump in <br /> Bedrooms Capaci GD' basement** <br /> 2 orless 750 1125 1500 <br /> 3 or4 1000 1500 2000 <br /> 5 or 6 1500 2250 3000 <br /> 7,8 or 9 2000 3000 4000 <br /> 'GD=garbage disposal,Must have multiple tanks or compartments <br /> " Must have multipte tanks,compartments or efFluent screen <br /> 3. Pump Tank Specifications <br /> D. Pump tank needed(yes/no) es Minimum size if needed 1000 gallons <br /> 4. SOILS(Site evaluation data) <br /> E. Depth to restricting layer= 98.6 (ELEVATION 0 F HIGHEST REDOX.) <br /> F. Maximum depth of system Item E-3 ft= 98.6 + 3 = 101.6 ft <br /> G. Texture Loam/Sand loam Percolation Rate Ompi <br /> if available <br /> H. SSF 1.67 ftz/gpd(see figure D-15) <br /> I. %Slope �% <br /> D-15 Soil Characteristics&SSF <br /> Perc Rate Soil Te�ure Soil Sizing Factors <br /> m i ftZl pd <br /> <0.1 ` Coarse sand 0.83 <br /> 0.1-5 Medium sand 0.83 o renc > o 0 o a sys em <br /> Loamy sand " Soil with>50%fine sand particles <br /> 0.1-5*' Fine sand 1.67 "' A mound must be used <br /> 6-15 Sandy foam 1.27 ""An other or performance system <br /> 16-30 Loam 1.67 <br /> 31 -45 Silt loam,silt 2.00 <br /> 46-60 Clay loam, 2.20 <br /> sandy clay <br /> or silty clay <br /> 61-120"" Clay,sandy 4.20 <br /> or siRy clay <br /> �120„�x Page 1 of 2 <br />