Laserfiche WebLink
� � <br /> ����� ���� <br /> {p Bunkers & Associates LLC <br /> structura engineers <br /> 6687 Forest Street <br /> Farmington, MN 55024 <br /> 651.366.2853 <br /> Date: May 30, 2012 <br /> To: Kuhl Design Build <br /> 1515 5`" St. S. Suite K <br /> Hopkins, MN 55343 <br /> Attn: Ashley Mitlyng <br /> From: Eric Bunkers <br /> Project: Myhran Residence <br /> 2280 Fox St. <br /> Orono, MN 55356 <br /> Proj. No: 12044 <br /> Subject: Proposed Remodeling <br /> Dear Ashley: <br /> As requested, we designed new structural members for the above referenced project. We have designed the <br /> new members using a roof and floor dead load of 15 psf, a roof snow load 35 psf, and a 40 psf floor live load <br /> in accordance with the Minnesota State Building Code. Our work only includes designing the new members <br /> as shown at the above reference project and is based on drawings provided by you. <br /> Attached are 6 framing sheets with annotated framing notes and 1 detail sheet showing the new members <br /> and connections. All framing shall be shored and temporarily braced as required by the contractor and all <br /> minimum nailing shall be in accordance with IRC Table R602.3(1). Lumber shall be minimum #2 SPF with <br /> treated lumber to be #2 S. Pine and engineered lumber to have Fb = 2600 psi with E = 1.9. Our calculations <br /> assume all lumber is of good quality and does not have large splits and checks and shall be visually <br /> inspected by the contractor at the time of construction. All fasteners in contact with treated lumber shall be <br /> G185 hot dipped galvanized or equal. Steel wide flange beams shall meet ASTM A992 and rebar shall be <br /> grade 60. <br /> Concrete used for footings (4"slump) and masonry core grout (8" slump) shall have a 28 day compressive <br /> strength of 3000 psi. The new footings have been designed as a typical spread footing based on a <br /> presumptive load-bearing value of 2000 psf in accordance with Table R401.4.1 of the IRC. The existing <br /> footings have been assumed to be typical spread footings on good soils that are assumed to be performing <br /> adequately. The contractor shall also verify the condition of structural members and foundations affected by <br /> the remodeling. Exterior grade shall slope away from the building and gutters with long downspouts should <br /> be used whenever possible. Foundation backfill shall be granular and the foundation system is assumed to <br /> have drain tile. <br />