� ' Technical Evaluation R�po�Q(7ER)
<br /> 7. T'est and �nginee`i�ig Sub���n8iating Llata:
<br /> 7.1. Test reports and data supporting the following materiai and structural properties:
<br /> 7.1.1. Flame spread and smoke developed rating tests by Intertek,2013.
<br /> 7.1.2. Room corner tests by Intertek,2013.
<br /> 7.1.3. Vertical and fateral fire propagation tests by SwRI and lntertek with analysis by Hughes Associates, 2014.
<br /> 7.1.4. Heat propagation (potential heat)testing by SwRI, 2009.
<br /> 7.1.5. Water vapor permeance testing by Exova, 2012.
<br /> 7.1.6. Water-resistive barrier testing by PEI,2008.
<br /> 7.1.7. Water-resisti�e barrier testing by ATI,2010.
<br /> 7.1.8. Air permeance testing by Intertek, 2010.
<br /> 7.1.9. Thermal resistance properties tests by�xova, 2010.
<br /> 7.1.10. Thermal resistance properties tests by QAI laboratories, 2014.
<br /> y.2. Some information contained herein is the result of testing and/or data analysis by other sources,which DrJ
<br /> relies on to be accurate as it undertakes its engineering analysis.
<br /> 7.3. DrJ has reviewed and found the data provided by other professional sources are credible. 7his information has
<br /> been approved in accordanc�with DrJ's procedure for acceptance of data from approved sources.
<br /> 7.4. DrJ's responsibility for data provided by approved sources is in accordance with professional engineering law.
<br /> 7.5. Where appropriate, DrJ relies on the derivation of design values, which have been codified into law through
<br /> codes and standards (e.g,, 1RC, WFCM, IBC, SDPWS, etc.). This includes review of code provisions and any
<br /> related test data that helps with comparative analysis or provides suppo�t for equivalency to an intended end-
<br /> use application.
<br /> 8. Findings:
<br /> 8.1. When installed�in accordance with the manufacturer's installation instructions and this TER, Thermasheath�-3,
<br /> 7hermasheath -XP, TSX-8500, TSX-8510 and TSX-8520 comply with,or are suitable alternatives to,the
<br /> applicable sections of the codes listed in 5ection?for the fallowing applications:
<br /> 8.1.1. Buildings const�ucted in accordance with the IRC and the IBC.
<br /> 8.1.1.1. TSX-8500, TSX-8510 and TSX-8520 are approved for use in exterior walls of buildings when instalted
<br /> in accordance with the IBC for Type I-IV construction. ,,,..
<br /> 8.1.2. Performance of foam pfastics in accordance with If�C.�s�.,ction f:3��and JEiC��;cti�n?g03.
<br /> 8.1.3. Thermasheath�-3, Thermasheath�-XP,TSX-8500, TSX-8510 and TSX-8520 are approved for use within
<br /> the building envelope, including, but not limited to, attic, crawlspace,wa(I,roof,ceiling,floor and
<br /> foundation assemblies.
<br /> 8.1.3.1. For use below grade, Thermasheath�-3, Thermasheath�-XP, TSX-8500,TSX-8510 and TSX-8520
<br /> may be installed horizontally under foundations and vertically on the interior side of footings and
<br /> foundation walls.
<br /> 8.1.4. Performance for use as insulating sheathing in accordance with 1RC Section N1102_1 and N i102:2 and
<br /> lECC 5eciion 40'l..
<br /> 8.1.5. Performance for use as a WRB in accordance with ll;,C^��ction R7p3.2 and IBC Section 1�Q4.2.
<br /> 8.1.6. Performance for use as an air barrier in accordance with /RC Section f�1102.4 and IECC�ection AQ?.
<br /> 8.1.7. Performance for use without a thermal barrier in accordance with/RC_Srction�316.5_3 and�;316,5,�
<br /> and if3C��ct�or 2u03.�.i.6. �
<br /> 8.1.8. Performance for use without a therma!barrier or ignition barrier in accordance with lrrti S�_r.iio��ri3iq 6
<br /> and 1�C S�:c�ion 26^3,�_O when installed in accordance with Section_5_4,3. �
<br /> TER No. 1309-03 � � Page 9 of 11
<br /> Rmax Thermasheath -3, Thermasheath -XP,
<br /> TSX-8500, TSX-8510&TSX-8520
<br />
|