My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00484 - new structure
Orono
>
Property Files
>
Street Address
>
F
>
Forest Arms Lane
>
945 Forest Arms Lane - 07-117-23-12-0019
>
Permits/Inspections
>
2015-00484 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:30:36 PM
Creation date
9/26/2016 2:21:21 PM
Metadata
Fields
Template:
x Address Old
House Number
945
Street Name
Forest Arms
Street Type
Lane
Address
945 Forest Arms La
Document Type
Permits/Inspections
PIN
0711723120019
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
__ _-- <br /> ' Rhvac-Residentiai 8�Light Commerciai HVAC Loads � Elite Software Development,Inc. <br /> ;West Metro Mechanical Inc. <br /> i Norwood MN 55368 Eaton 345 Forest Arms l.ane,Orono,MN' <br /> ___ .__ - _P�4��� <br /> ---- --- _ _ __.__ __ <br /> Miscellaneous Report <br /> - --- <br /> ___ <br /> System 1 Outdoor Outdoor Outdoor Indoor indoor Grains <br /> ';)nput Data ________ Dry B_ulb Wet Bufb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter: -11 -11.42 79% n/a 72 n/a <br /> Summer: 88 71 44% 50% 72 2g,gg <br /> i Du�c_Si_zin�c Inputs _ — - ----------------� <br /> Main Trunk Runouts ` "-� <br /> Calculate: Yes Yes <br /> , Use Schedule: Yes Yes <br /> ' Roughness Factor: 0.00300 0.01000 <br /> Pressure Drop: 0.1000 in.wgJ100 ft. 0.1000 in.wg./100 ft. <br /> ' Minimum Velocity: 650 ftJmin 450 ft./min <br /> I Maximum Velocity: 900 ft./min 750 ftJmin ! <br /> ; Minimum Height: 0 in. 0 in. <br /> ' Maximum Height: 0 in. 0 in. <br /> --__ _ ----- _—_-----_ _ _------------ _.- - - <br /> �Qutside Air Data —'-T� , <br /> ' �lintBL � ,�mmPr <br /> Infiltration Specified: 0.190 AC/hr 0.100 AC/hr <br /> i 103 CFM 54 CFM <br /> ; Infiltration Actual: 0.190 AC/hr 0.100 AC/hr <br /> ; Above Grade Volume: X 32,486 Cu.ft. X 32,486 Cu.ft. <br /> , 6,172 Cu.ft./hr 3,249 Cu.ft./hr ' <br /> , X 0.0167 X 0.0167 <br /> ! Total Building Infiltration: 103 CFM 54 CFM <br /> ' Total Building Ventilation: 130 CFM 130 CFM <br /> i <br /> i <br /> ' ---System 1--- <br /> Infiltration &Ventilation Sensible Gain Multiplier: 17.08 = (1.10 X 0.970 X 16.00 Summer Temp. Difference) <br /> , Infiltration &Ventilation Latent Gain Multiplier: 19.79 = (0.68 X 0.970 X 29.99 Grains Difference) <br /> I Infiltration &Ventilation Sensible Loss Multiplier: 88.58 = (1.10 X 0.970 X 83.00 Wnter Temp. Difference) <br /> Winter Infiltration Specified: 0.190 AC/hr(103 CFM), Construction: Semi-Tight <br /> I Summer Infiltration Specified: 0.100 AC/hr(54 CFM), Construction: Semi-Tight <br /> �I <br /> � - _ ___ ____ _ _ _ _ ___ _ _ ___ , <br /> _ -- _ _. __. <br /> C:\...\Eaton New Construction.rh9 Tuesday, April 21, 2015, 9:56 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.