2010-00542 - new mound septic
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
515 Ferndale Road North - 36-118-23-14-0006
>
Septic
>
2010-00542 - new mound septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:01:49 PM
Creation date
8/16/2016 2:04:58 PM
Metadata
Fields
Template:
x Address Old
House Number
515
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
515 Ferndale Road North
Document Type
Septic
PIN
3611823140006
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' A. Catculate Clean Sand Lift: 3 feet minus Depth to Limiting Layer (1.C) = Clean Sand Lift (1 ft minimum) <br /> � 3.0 ft - 1.7 ft= 1.3 ft <br /> B. Calcutate Upslope Height: C(eQn Sand Lift(4.A) + media depth (1 ft.)+ cover (1 ft.) = Upslope Height <br /> 1.3 ft+ 1.0 ft+ 1.0 ft= 3.3 ft <br /> �. Select Ups(ope Berm Multip(ier <br /> (based on tand slope): 2-�0 (figure D-34) <br /> D. Calculate Ups(ope 8erm Width: Mu(tiptier (4.C)X Upslope Mound Height (4.6) = Ups(ope Berm Width <br /> 2.70 x 3.3 ft= 9.0 ft <br /> E. Calculate Drop in Elevation Under Media:Media Width (2.8) X Land 5(ope(1.E) : 100=Drop (ft) <br /> 10.0 x 12.0 %: 100= 1.2 ft <br /> F. Calculate Downslope Mound Height: Upstope Height (4.6) + Drop in Elevation (4.E)= Downslope Height <br /> 3.3 ft+ 1.2 ft= 4.5 ft <br /> Setect Downs(ope Berm Multiplier <br /> G' (based on land slope): 6.25 (figure D-34) <br /> H. Calcutate Downsiope Berm Width: Mu(tip(ier (4.G)X Downslope Height(4.F) = Downslope Berm Width <br /> 6.25 x 4.5 ft= 28.0 ft <br /> i. Calculate Minimum Berm to Cover Absorption Area: Downs(ope Absorption Width (3.B or 3.Cj +4 ft. = ft <br /> 5.4 ft+ 4 ft= 9.4 ft <br /> J. Design Downstope 8erm =greater of 4H and 41: 28.0 ft <br /> K. Setect Endslope Berm Mu(tip(ier: 3.00 (usualty 3.Q or 4.0) <br /> L. Calculate Ends(ope Berm (4.K)X Downs[ope Mound Height (4.F) =Endsfope Berm Width <br /> - 3.00 x 4.5 ft= 14.0 ft <br /> M. Calcutate Mound Width: Upslope Berm Width(4.D)+Media Width (2.B)+Downslope Berm Width (4.J) =ft <br /> 9.0 ft+ 10.0 ft+ 28.0 ft= 47.0 ft <br /> N. Calculate Mound Length: Endslope Berm Width (4.L) +MediQ length (2.C)+Ends(ope Berm Width (4.L) =ft <br /> 14.0 ft + 63.0 ft+ 14.0 ft= 91.0 ft <br /> D-34:Siopc R1ultipNer Table <br /> Land Slope� 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 <br /> UpslOpe 3:t 3.00 2.91 2.83 2.75 2.68 Z.61 2.Sa 2.-18 Z.a2 2.36 2.31 216 2.21 2.17 Z.13 2.C9 1.05 2.03 2.00 1.97 t.S5 1.93 �.91 i.89 1.87 1.85 <br /> Bernl RatiO -i:t a.00 3.85 3.70 3.57 3.d5 3.33 3.23 3.12 3.03 2.9d 2.86 2.78 2.70 2.62 2.55 2.aS 2.41 2.35 2.29 2.23 2.18 2.13 2.08 2.03 1.98 1.43 <br /> LdRd 51ope% 0 I 2 3 4 5 6 7 S 9 10 11 12 f 3 14 15 16 17 18 19 20 21 22 23 24 25 <br /> �OV!(1S10� 3:1 3.00 3.09 3.19 3.3D 3.d1 3.53 3.66 3.80 3.95 4.11 d.29 d.d8 5.69 d.95 5.2-t 5.55 5.84 6.2J E.63 7.0�1 7.-t7 7.93 8.42 8.93 9..16 t0.02 <br /> BE�rnI Rat10 d:1 J•OD d•17 435 4.S�t 4.76 S.CO 5.26 S.Sb 5.E8 615 6.67 7.1-! 7.69 8.29 8.92 9.57 10.2-! 10.9�1 11.67 12.a2 93.19 13.99 3�.92 l5.67 tE.5d 17.JJ <br /> 5. ORGANIC LOADING: (if pretreatment is being used) <br /> A. Organic Loading = Design Ftow X Fstimated 80D in mg/L in the effluent X 8.35 : 1,000,000 (See Table ill) <br /> gpd X mg/L X 8.35: 1,000,000 = lbs BOD/day <br /> B. Calculate System Organic Loodin : (bs. 80D (5.A) :Media Area (2.A) = lbs/da /ft2 <br /> tbs/day = ftz = lbs/day/ftZ <br /> Table III (7083.4030) <br /> BOD Treatment BOD (mg/L) <br /> Level A 15 <br /> Level B 25 <br /> Level C 125 <br /> 6. MOUND DIMENSIONS <br /> J J <br />