My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005-P09251 - new structure
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
507 Ferndale Road North - 36-118-23-13-0007
>
Permits/Inspections
>
2005-P09251 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:01:18 PM
Creation date
8/16/2016 12:09:27 PM
Metadata
Fields
Template:
x Address Old
House Number
507
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
507 Ferndale Road North
Document Type
Permits/Inspections
PIN
3611823130007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PASSIVE MAKE-UP AIR QPENING 5CHEDULE <br /> TABLE FOR SIZING PASSIVE MAKE-UP AIR OPENINGS Dlatneter Path 0 Path I Path 2 <br /> Nt�tes: a) 'I'his table assumes 20 feet of smooth unobstructed round 3 inches 50 cfm 35 efm I S efm <br /> duct with three 90°elbows and a screened hood 4 inehes 90 cfm 60 cfm 30 efm <br /> b} Equivalent designs calculated usin�pressures of 50 Pasc�ls 5 inches 140 cfm 1�0 cfm 45 cfm <br /> for Yath 0, 25 Paseals for Path 1, and 5 Paseals for Path 2 6 inches 200 cfm 140 cfm 65 cfm <br /> may be used. 7 inches 270 cfm 190 cfm 85 cfm <br /> c) If a make-up air opening is used�vith no duct or elbows,the 8 inches 3�0 cfm 250 cfm 110 cfm <br /> D�ameter can be decreased by 1 inch. 9 inches 450 cfm 320 cfm 140 efm <br /> d) If flex duct is used, inerease diameter b� 1 inch. 10 inches 570 cfm 400 cfm 1 SO cfm <br /> Make-u Air A lication/Location CFM O enin size Duct�t�v e <br /> ❑ Smouth ❑ l�lcz ❑ O enin�onlv <br /> ❑ Smooth ❑ Flcz ❑O enin�onl�� <br /> ❑ Smooth ❑ Flex ❑O enin�onlv <br /> ❑ Smooth ❑ Flca ❑ O enin�onl � <br /> AGGREGATE MAKE-UP AIR WORKSHEET <br /> INSTRUC'IIONS <br /> Step l. Complete E;xhausl Schedule on the right indicating cfm of largest device in each category. EXHAUST SCHEDULE <br /> Step 2. Complete the('ombustion Equipment Schedule on preceding page. DEVICE CFM <br /> Step 3. Choose a path with a Y(Yes)for all sel�,cted equipment. Clo h� <br /> ' t es drver <br /> Step 4. Complete,�ggregate,ti�ake-up Air table below for chosen path. Using the total cfm from the Kitchen exhaust <br /> I�.xhaus�Sched:ile,indicate tlow in cfm for proposed method(s)of providing make-up air. Other exhaust <br /> Step 5. Fill out the Passive tifake-t�p Air Opening Schedzrle above. TOTAI, <br /> ❑ Path 0 — Aggregate Make-U� Alt' MethOd Passive Passive Powered Make-up <br /> (nfiltration O enin <br /> Passive infiltration for up to 425 cfm <br /> Passive openings far cfms over 425 <br /> Powered to match flow for cfms over 985 <br /> ❑ Path 1 —Aggl'egate Make-up AiI' MethOd Passive Passive Powered Make-up <br /> Intittration O enin * <br /> Passive intiltration up to US cfm* � <br /> Passive openings for cfms over 175 <br /> Powered to match flow tor cfms over 56� � <br /> * [f a closed controlled solid-fuel burning appliance is installed in Path 1,then a passive opening must be installed to provide make-up air t�ir <br /> the clothes dryer and for any central vacuum that exhausts to the outside. <br /> ❑ Patfl 2 — E�ggi'egate Make-U� f�ll' Met�lOC� Passive Passive Po�vcred <br /> fnf3ltration Q nin Make-u <br /> Passive opcnings for up to 175 cfm <br /> Powered to match flo�v for cfms over 175 N/n <br /> ❑ Path 3 — Aggt'egate Make-Up Ai1' MethOd Passive Passive Pow�ered <br /> [nfiltration O enin Makc-u <br /> Powered to match flow �;;n �;;A <br /> l� <br />
The URL can be used to link to this page
Your browser does not support the video tag.