My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-00101 - mechanical
Orono
>
Property Files
>
Street Address
>
E
>
Elmwood Avenue
>
1161 Elmwood Avenue - 07-117-23-14-0073 - New PID
>
Permits/Inspections
>
2014-00101 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:31:58 PM
Creation date
7/27/2016 2:34:50 PM
Metadata
Fields
Template:
x Address Old
House Number
1161
Street Name
Elmwood
Street Type
Avenue
Address
1161 Elmwood Ave
Document Type
Permits/Inspections
PIN
0711723140073
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� , <br /> ' Directions-!n order to determine the makeup air, Table 501.3.1 must be filled out(see belowJ. For most new installations, co/umn A <br /> will be appropriate,however,if atmospherically vented appliances or solid fue/appliances are installed, use the appropriate co/umn. <br /> for existing dwellings,see IMC 501.3.3. Please note,if the makeup air quantity is negotive, no additiona!makeup air will be re- <br /> quired for ventilation,if the va/ue is positive refer to Table 501.3.2 and size the opening. Transfer the cfm,size of opening and type <br /> (round,rectangular,flex or rigid)to the last line of section D. The make-up air supp/y must be installed per IMC 501.3.2.3. <br /> Table 501.3.1 <br /> PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST E4UIPMENT IN DWELLINGS <br /> (Additional combustion air will be required for combustion appliances,see KAIR method for calculations) <br /> One or multiple power One or multiple fan- One atmospherically vent Multiple atmospherical- <br /> vent or direct vent ap- assisted appliances and gas or oil appliance or ly vented gas or oil <br /> piiances or no combus- power vent or direct vent one solid fuel appliance appiiances or solid fuel <br /> tion appliances appliances appliances <br /> Column C Column D <br /> Column A Column B <br /> 1. <br /> a)pressure factor 0.15 0.09 0.06 0.03 <br /> (cfm/sf) <br /> b)conditioned floor area(s�(including 2978 <br /> unfinished basements) <br /> Estimated House Infiltration(cfm�:[la �6 <br /> x lb] <br /> 2.Exhaust Capacity <br /> a)continuous exhaust-only ventilation 160 <br /> system(cfm);(not applicable to ba- <br /> lanced ventilation systems such as <br /> HRV) <br /> b)clothes dryer(cfm) 135 135 135 135 <br /> c)80Y of largest exhaust rating(cfm►; <br /> Kitchen hood typically 64 <br /> (not applicable if recirculating system <br /> or if powered makeup air is electrically <br /> interlocked and match to exhaust) <br /> d)80�of next largest exhaust rating <br /> (cfm); bath fan typically NOt <br /> (not applicable if recirculating system <br /> or if powered makeup air is electrically Applicable <br /> interlocked and matched to exhaust) <br /> Total Exhaust Capacity(cfm); 359 <br /> (2a+2b+2c+2d] <br /> 3.Makeup Air Quantity(cfm) <br /> a)total exhaust capacity(from above) 359 <br /> b)estimated house infiltration(from <br /> above) `�6 <br /> Makeup Air Quantity(cfm); <br /> [3a—3b] _87 <br /> �if value is negative,no makeup air is <br /> needed) <br /> 4.For makeup Air Opening Sizing,refer <br /> to Tabie 501.4.2 Not Required <br /> A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power vent <br /> and direct vent appliances may be used.) <br /> B. Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may also be in- <br /> cluded.) <br /> C. Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. <br /> D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or oil <br /> appliances and solid fuel appliances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.