Laserfiche WebLink
, f <br /> �M�' �'b!�'� �':� '� t:. � <br /> New Construction Energy Code Compliance Certificate � ��, �� � �� �_ �, <br /> Per N I IU1-8�3uilding CeRificate.A building certificate shall be postzd in a p�manently v�sible location inside ��e Certificate Posted � � u `�_ " �' <br /> the buildu�g. The certificate shall be completeci by the builder and shall list info[mation and values of ��,}���� ��°'� �i� � <br /> � <br /> com nenu listed in Table NI]01.8. <br /> Mailing Address of the DAelling or Dwelling Ueil <br /> 1161 Elmwood Ave Orono <br /> Name of Residenlial Coolrac[or MN I,icense Number <br /> Colfax Homes <br /> Community Plan ID <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply X Passive(No F'an) <br /> o „ <br /> c <br /> v � <br /> °; �, Aetive([3'ith fan and monometer or <br /> �' Q i, other system monitoring device) <br /> �e _ p 'o 0 <br /> ,°, a b � U v .o° b � <br /> a Q CA W abi U v '� a <br /> Insulation Location � o z � � v a w W o� <br /> t� �^ � � ~ <br /> � ' � � � � � a v v <br /> 0 0 � � o 0 5 ao au <br /> F- S z w w w w � iz rz ��'Please Describe Hcre <br /> 13elow Entire Slab <br /> Foundation Wall R-rJ X Type in location:interbr e�cterbr or integrat <br /> Perimeter of Slab on Grade <br /> I2im Joist(Hbundation) R-12 X Type in locatbn:interqr euterior or integrel <br /> n <br /> Rim Joist(1 Floorf�) R-�2 X Type m location:interbr exterbr or integral <br /> �va11 R-19 X <br /> ('eiling,tlat R-50 X <br /> Ceiling,vaulted R-50 X <br /> E3ay Windows or cantilevered atxas R-30 X <br /> I3onus room over garage <br /> Dexcribe other insulated areas <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Avcrage U-H'actor(excGides slzvlights and one door)U: 035 Not applicable,al)ducts locatcd in conditioned space <br /> Solar Heat Gain Ccefficient(S}IGC): -8 R-value <br /> MECHANICAL SYSTEMS Make-up Air Seleer a Type <br /> AppllanCes Heating System Domestic Water I�eater Cooling System Not required per mech.code <br /> Fue�1'ype NAT GAS NAT GAS R-410A P���e <br /> Manut'acturer BRYANT RHEEM BRYANT Powered <br /> Interlocked with e�aust devioe. <br /> Model 912S660080 42VP75FW 1113ANA036 Describe: <br /> Input in 80000 Capacity in 75 Chuput in 3 O[her,describe: <br /> lidting or Size E3TUS. Gallons Cons- <br /> Heat Loss 62,402 Heat Gain. 28,425 Location of duet or system: <br /> StruMure's Calculated <br /> AFLJE or 92 SEER_ ]3 <br /> }1SPF% <br /> ('alculatad �4201 <br /> Efficiencv coolin>load_ Cfrn's <br /> roun uc <br /> Mechanical Ventilation System "metal duct <br /> ............ . .....................................o�».�.,.,,,,.,....s�y�.....�.....�..........�...s.....,.,..��...,.,�.,..... <br /> ource heat pump with gas back-up fiunace): Full bath&Powder to get Panasonic Whispr,�rC3I2f�:}?N fans that run ai 50 Combustion Ai� Seled a Type <br /> fm constant and ramp up to 80 cfin upon motion sensing for 30 minutes No[reyuued per mech.code <br /> Seled Tyye Passive <br /> Heat Recover Ventilator(HRV) Capacity in cfins: I,ow: }�igh: (hher,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duc[or system: <br /> Con[inuous e�austing fan(s)rated capacity in efrns: 50 cf,constan[-80 cfm uEwn motion fumaee room <br /> Loca[ion of fan(s),describe: Full bath&powder Cfm's <br /> Capacity continuous ventilation rate in cfms: 75 "round duct OR <br /> I� Total ventitaGon(intermittent+continuous)rale in cfins: � I�ll �� � "meiai duci II <br />