My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Preliminary Septic Design
Orono
>
Property Files
>
Street Address
>
B
>
Bayside Road - (AKA: Co. Rd. 84)
>
3960 Bayside Road - 05-117-23-22-0016 - 2nd New PID
>
3960 Bayside Rd - 05-117-23-22-0007 - Old PID
>
Correspondence
>
Preliminary Septic Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:19:57 PM
Creation date
7/7/2016 4:18:03 PM
Metadata
Fields
Template:
x Address Old
House Number
3960
Street Name
Bayside
Street Type
Road
Address
3960 Bayside Rd
Document Type
Correspondence
PIN
0511723220016
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purpletode Mound Design <br /> www.SepticResource.com (vers 15.2} <br /> Property Owner: Modern Construction Date: 6/11/2016 <br /> Site Address: 34b0 Bays9de Rd., Oro�o PID: <br /> Comments: <br /> instructions: ;.=~.'_�:;�� =enter data � = acijust if desired � � computer catcutated - DO IVOT CHANGE! <br /> t) �` ��.;: bedroom Type � �te�tdet�tial :�3i v � =5ystem <br /> 2� 750 GPD design flow <br /> rF w� :� S P P P P <br /> 3} n�����;;��� Garba e dis osal or um ed to se tic <br /> a} 1500 Gal Septic tank (code minimum) 15q4: Gal Septic tank (des�gn size / LUG req d} <br /> 3 -!{e .�.u?m•,a���u v rx—i vs � � !l <br /> Tank options:°h�j5e � s�������'���_.,�:_. , <br /> - :__..�,..>.,�,�:�... ..._.. ....� :�::� <br /> s� iri, ".c:y,: . <br /> �`�:,�;�GPD/ftZ mound sand toading rate contour laading rate of ;<���;_:�; req's a min 62.5 ft. long rockbed <br /> 6} `:;�'1'Q�O:�ft rockbed width 62.5 ft rockbed length <br /> .x�,�--—e <br /> �� �=;3�0�;'�ft lateral spacing �����#�;�F;ft perforation spacing (maximum of 3 for both) ' <br /> �nd-fee�manifold connection <br /> s) �taterals 60.5 feet long 21.0 perts / lateral 63 perfs total <br /> {1/2 a perf ineans the flrst perf starts at the middie feed man9fold) <br /> z;.:- .., � <br /> 9� ,+k�<Y;}",�: inth per#s at ;=�<;'f�`;�`feet residual head gives 0.74 gpm flow rate per perforation <br /> for thls perf size 8 spacing, ft pipe size on line 12, max perfs/lateral= 25 , �ine�8 must be less --> oK <br /> ���;�,....#; <br /> to� �:,:�:0;„; doses per day (4 minimum) <br /> i i� 188 gallons per dose (treatment volume} <br /> 2.00 5x <br /> iz� 2.00 inch diameter latera�s must be used to meet"4x pipe volume" requirement <br /> 2.00 3x <br /> ,:;. <br /> is� %t����= feet of ;r�=�;Q;rU inch supply tine leads to 6 gallons of drainback volume <br /> (Tip: "top feed"manifold to control the drainback) <br /> ta� 194 ga{lons TOTAL pump out volume (treatment+ drainback) <br /> ts� � =b�,�feet vertical lift from pump to mound laterals, leads to a: <br /> �6� 47 GPM C 14 feet of head, Pump�equirement (note: >SOgpm may require an extra 3-6'of head) <br /> ��) 10Q0 gal Dose tank (code minimum} ,1dOf�=_ gal Dose tank (design size / LUG reqd) at ���2.4�;�pi <br /> leads to a <br /> �s� 8.8 inch swing on Demand float, or timed dosinq of 4.1 min ON {confirm pump rate with drawdown <br /> (this delivers Average flow, =70%of Peak design flow} 9 hrs OFF test and adjust as necessary) <br /> i9) �y�:i1�:':r,inthes from bottom of tank to"Pump OFF"float <br /> zo} 29 inches from bottom of tank to"Pump ON"float, or 12 inches to"Timer ON"float if time dosed <br /> 2�� 24 inches from bottom of tank to"Hi Level"float, or � inches to"Hi Level"flaat if time dosed <br /> 2z� 472 galtons reserve capacity {after High Level Atarm is activated) <br /> i <br /> � <br /> � <br /> I <br /> � <br /> � <br /> I <br /> i <br /> i <br /> � <br /> I <br /> I <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.