Laserfiche WebLink
SUMMIT FIRE PROTECTION <br /> 575 MINNEHAHAAVE.W•ST.PAUL,MN 55103•(651)251-1880 3026 40TH AVE.IVW•ROCHESTER,MN 55901 •(507)280-0622 <br /> '418 GR�AT OAK DR.,WAITE PARK,MN 56387•(320)257-6390 760 LIBERTY WAY,NORTH LIBERTY,IA 52317•(319)665-4330 <br /> 4208 ENTERPRISE CIRCLE•DULUTH,MN 55811 •(218)740-4412 <br /> SHEET 1 OF 2-Use sepazate sheet for each building inspection REP�RT�F''I1�SPECTI�lv <br /> MINNESOTA LICENSE NO. C0075 JOB NUMBER <br />�' INSPECTION NAME BUILDING/LOCATION <br /> STREET INSPECTOR <br /> CITY&STATE DATE <br /> Owner's Section(to be answered by Owner or Occupant) <br /> A. Explain any occupancy hazard changes since the previous inspection: <br /> B. Describe fire protection modifications made since last inspection: <br /> C. Describe any fires since last inspection: <br /> D. When was the system piping]ast checked for stoppage,corrosion of foreign inaterial? <br /> E. When was the dry-piping system last checked for proper pitch? <br /> E Are dry valves adequately protected from freezing? <br /> Signature Title � Date <br /> Inspector's Section(All responses reference current inspection) NA=NOT APPLICABLE <br /> 1. General <br /> a.Is the building occupied?DYes ❑No <br /> b.Are all systems in service? DYes❑No <br /> c.Is there a minimum of 18 in.(457 mm)clearance between the top of the storage and the sprinkler deflectors? OYes ❑No <br /> d.Does all electrical heat tape appear to be satisfactory? ❑Yes ❑No 0�NA <br /> e.Does the hand hose or standpipe on the sprinkler system(s)appear to be satisfactory? ❑Yes ❑No O NA <br /> 2. Control Valves(See Item I5.) � <br /> a.Are all sprinkler system control valves and all other valves in the appropriate open or closed position? ❑Yes ❑No <br />�' b.Are all control valves in the open position locked,sealed or equipped with a tamper switch? OYes 0 No <br /> 3. Tanks,Pumps,Fire Department Connections <br /> a.When was fire pump last tested for performance? <br /> b.Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? ❑Yes❑No ❑NA <br /> c.Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves tight? DYes ❑No ❑NA <br /> Are they accessible and visible? OYes 0 No ❑ NA <br /> 4. Wet Systems � <br /> a.Are cold weather valves(O.S.&Y.)in the appropriate open or closed position? ❑Yes ❑No O'�NA <br /> b.Have antifreeze system solutions been tested? ❑Yes ❑No ❑NA � <br /> c.What temp is antifreeze? � <br /> d In areas protected by wet system(s),does the building appear to be properly heated in all areas,including blind attics and perimeter areas <br /> where accessible?❑Yes ❑No O�NA <br /> 5. Dry System(See Items l] to 13) ,� <br /> a.Are dry valve(s)in service? ❑Yes ❑No ❑NA <br /> b.Are the air pressures and priming water levels in accordance with the manufacturer's instructions? ❑Yes ❑No 0 NA � <br /> c.Has the operation of the air or nitrogen supplies been tested? OYes❑No ❑NA Are they in servicc? ❑Yes❑No ❑NA � <br /> d.Were low points drained during this inspection?OYes ❑No❑NA How many? <br /> e.Did quick-opening devices operate satisfactorily? ❑Yes ❑No C}NA <br /> f.Did the dry valve(s)trip properly during the trip pressure test? DYes ❑No❑NA <br /> g.Did the heating equipment in the dry-pipe valve room(s)operate at time of inspection? DYes ❑No ❑NA <br /> 6. Special Systems(See ltem 14.) � <br /> a.Did the deluge or pre-action valves operate properly during testing? ❑Yes ❑No ❑NA � <br /> b.Did the heat-responsive devices operate properly during testing? ❑Yes ❑No❑NA <br /> c.Did supervisory devices operate during tes[ing? ❑Yes❑No ❑NA <br /> d.Did flow for kitchen hood system shut off gas or electric? ❑Yes 0 No ❑NA <br /> 7. Alarms <br /> a.Did water motor(s)and gong(s)test satisfactorily? ❑Yes 0 No ❑NA <br /> b.Did electric alarm(s)test sarisfactorily? DYes❑No ❑NA <br /> c.Did supervisory alarm service test satisfactorily? ❑Yes ❑No ❑NA <br /> d.Did tamper switches test satisfactorily? ❑Yes ❑No 0 NA �� � <br /> 8. Sprinklers <br /> a.Are all sprinklers free from corrosion,loading or obstruction to spray discharge? OYes ❑No <br /> b.Are sprinklers less than 50 years old?(Older sprinklers require sample testing) ❑Yes ❑No <br /> c.Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing) ❑Yes ❑No � <br /> d.Is stock of spare sprinklers available? DYes ❑No <br /> e.Does the exterior condition of sprinkler system appear to be satisfactory? OYes❑No <br /> f.Are sprinklers of proper temperature rating for their locations? ❑Yes ❑No <br /> g.Are any sprinkler heads{on a recall list?❑Yes ❑No <br /> Signature: . Date: <br /> � <br />