My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
fire code inspections
Orono
>
Property Files
>
Street Address
>
D
>
Dunwoody Avenue
>
2420 Dunwoody Avenue - 20-117-23-21-0018
>
Misc
>
fire code inspections
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:51:49 PM
Creation date
7/7/2016 1:12:03 PM
Metadata
Fields
Template:
x Address Old
House Number
2420
Street Name
Dunwoody
Street Type
Avenue
Address
2420 Dunwoody Avenue
Document Type
Misc
PIN
2011723210018
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUMMIT FIRE PROTECTION <br /> 575 MINNEHAHAAVE.W•ST.PAUL,MN 55103•(651)251-1880 3026 40TH AVE.IVW•ROCHESTER,MN 55901 •(507)280-0622 <br /> '418 GR�AT OAK DR.,WAITE PARK,MN 56387•(320)257-6390 760 LIBERTY WAY,NORTH LIBERTY,IA 52317•(319)665-4330 <br /> 4208 ENTERPRISE CIRCLE•DULUTH,MN 55811 •(218)740-4412 <br /> SHEET 1 OF 2-Use sepazate sheet for each building inspection REP�RT�F''I1�SPECTI�lv <br /> MINNESOTA LICENSE NO. C0075 JOB NUMBER <br />�' INSPECTION NAME BUILDING/LOCATION <br /> STREET INSPECTOR <br /> CITY&STATE DATE <br /> Owner's Section(to be answered by Owner or Occupant) <br /> A. Explain any occupancy hazard changes since the previous inspection: <br /> B. Describe fire protection modifications made since last inspection: <br /> C. Describe any fires since last inspection: <br /> D. When was the system piping]ast checked for stoppage,corrosion of foreign inaterial? <br /> E. When was the dry-piping system last checked for proper pitch? <br /> E Are dry valves adequately protected from freezing? <br /> Signature Title � Date <br /> Inspector's Section(All responses reference current inspection) NA=NOT APPLICABLE <br /> 1. General <br /> a.Is the building occupied?DYes ❑No <br /> b.Are all systems in service? DYes❑No <br /> c.Is there a minimum of 18 in.(457 mm)clearance between the top of the storage and the sprinkler deflectors? OYes ❑No <br /> d.Does all electrical heat tape appear to be satisfactory? ❑Yes ❑No 0�NA <br /> e.Does the hand hose or standpipe on the sprinkler system(s)appear to be satisfactory? ❑Yes ❑No O NA <br /> 2. Control Valves(See Item I5.) � <br /> a.Are all sprinkler system control valves and all other valves in the appropriate open or closed position? ❑Yes ❑No <br />�' b.Are all control valves in the open position locked,sealed or equipped with a tamper switch? OYes 0 No <br /> 3. Tanks,Pumps,Fire Department Connections <br /> a.When was fire pump last tested for performance? <br /> b.Are fire pumps,gravity tanks,reservoirs and pressure tanks in good condition and properly maintained? ❑Yes❑No ❑NA <br /> c.Are fire department connections in satisfactory condition,couplings free,caps in place,and check valves tight? DYes ❑No ❑NA <br /> Are they accessible and visible? OYes 0 No ❑ NA <br /> 4. Wet Systems � <br /> a.Are cold weather valves(O.S.&Y.)in the appropriate open or closed position? ❑Yes ❑No O'�NA <br /> b.Have antifreeze system solutions been tested? ❑Yes ❑No ❑NA � <br /> c.What temp is antifreeze? � <br /> d In areas protected by wet system(s),does the building appear to be properly heated in all areas,including blind attics and perimeter areas <br /> where accessible?❑Yes ❑No O�NA <br /> 5. Dry System(See Items l] to 13) ,� <br /> a.Are dry valve(s)in service? ❑Yes ❑No ❑NA <br /> b.Are the air pressures and priming water levels in accordance with the manufacturer's instructions? ❑Yes ❑No 0 NA � <br /> c.Has the operation of the air or nitrogen supplies been tested? OYes❑No ❑NA Are they in servicc? ❑Yes❑No ❑NA � <br /> d.Were low points drained during this inspection?OYes ❑No❑NA How many? <br /> e.Did quick-opening devices operate satisfactorily? ❑Yes ❑No C}NA <br /> f.Did the dry valve(s)trip properly during the trip pressure test? DYes ❑No❑NA <br /> g.Did the heating equipment in the dry-pipe valve room(s)operate at time of inspection? DYes ❑No ❑NA <br /> 6. Special Systems(See ltem 14.) � <br /> a.Did the deluge or pre-action valves operate properly during testing? ❑Yes ❑No ❑NA � <br /> b.Did the heat-responsive devices operate properly during testing? ❑Yes ❑No❑NA <br /> c.Did supervisory devices operate during tes[ing? ❑Yes❑No ❑NA <br /> d.Did flow for kitchen hood system shut off gas or electric? ❑Yes 0 No ❑NA <br /> 7. Alarms <br /> a.Did water motor(s)and gong(s)test satisfactorily? ❑Yes 0 No ❑NA <br /> b.Did electric alarm(s)test sarisfactorily? DYes❑No ❑NA <br /> c.Did supervisory alarm service test satisfactorily? ❑Yes ❑No ❑NA <br /> d.Did tamper switches test satisfactorily? ❑Yes ❑No 0 NA �� � <br /> 8. Sprinklers <br /> a.Are all sprinklers free from corrosion,loading or obstruction to spray discharge? OYes ❑No <br /> b.Are sprinklers less than 50 years old?(Older sprinklers require sample testing) ❑Yes ❑No <br /> c.Are quick response and residential sprinklers less than 20 years old?(Older sprinklers require sample testing) ❑Yes ❑No � <br /> d.Is stock of spare sprinklers available? DYes ❑No <br /> e.Does the exterior condition of sprinkler system appear to be satisfactory? OYes❑No <br /> f.Are sprinklers of proper temperature rating for their locations? ❑Yes ❑No <br /> g.Are any sprinkler heads{on a recall list?❑Yes ❑No <br /> Signature: . Date: <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.