My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
06-20-2005 Planning Commission Packet
Orono
>
Planning Commission
>
2005
>
06-20-2005 Planning Commission Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/4/2012 11:34:51 AM
Creation date
4/4/2012 11:34:28 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
. #05-3097 <br /> June 20,2005 <br /> P�ge 3 of 4 <br /> - 4. P�°oposed public ��oczd inZpr�ovenzents: In order to meet sight distance standards a <br /> section of Fox Street mlist be lowered to meet vei�tical curve requirements. Tl�is <br /> means that the easterly approximately 250' from the new road access would be <br /> lowered 1-5', ciepending on where you are in the curve. This gives 400' of <br /> stopping distance from the crest of the hill to the new road access, meeting City <br /> Engineer standards. <br /> 5. Elamination of unrrecess�r�y accesses onto Fox Str•eet: At the time of new <br /> development, it has been City policy that all unnecessary accesses be eliminated. <br /> This is of greater importance on tlus stretch of Foa Street where sight distance <br /> issues exist. Staff would recommend that any preliminary plat approval <br /> recoinmendation include elimination of the existing drive access at the west end <br /> of the site as well as the guest house access. The City Engineer has determined <br /> that a driveway coruiecting the guest house to the existing main house drive can <br /> be achieved. <br /> 6. Septic sites for proposed Lot 6.• Both the main house and the guest house have <br /> . non-conforming septic systems that must be replaced by 12-31-2010. The Ciry's <br /> Septic Code requires primary and alternate 5 bedroom septic sites for both the <br /> main house and gz.iest house for a total of four, 5 bedroom sites. The applicants <br /> have proposed two 5 bedroom sites. The applicants will either have to find two <br /> additional septic sites, or expand the existing five bedroom sites to 7 bedrooin <br /> sites to accorrunodate the guest house. This is technically a variance from the <br /> septic code and the Planning Commission should determine whether this is <br /> acceptable for new development. <br /> 7. Rural O�rsis study: Staff feels the City Council should determine what, if <br /> anything, the applicant should be required to complete to meet the goals of the <br /> rural oasis study. <br /> 8. Account fo�° "ditch wetlands" on pro�osed Lot 5: At the last Planning <br /> Corrunission meeting the applicants were directed to re-configure lot lines so that <br /> the wetlands labeled ditch wetlands could be deducted from the dry buildable <br /> acreage and still rneet a 2 acre minimum. The applicants have made this revision <br /> and it is shown on the revised plans. <br /> 9. Ti°�ril Ensenaent:• The Park Commission lias determined they will not seek a trail <br /> easement. <br /> 10. Blz ff It appears that the bluff on proposed lot 5 and subsequently the 30' setback <br /> from the top of bluff have been shown incorrectly. Staff's analysis pLits the <br /> eaisting house, at the closest location, approxiinately 20' from the top of bluff. <br /> While the existing house retains a legal non-conforming status, it should be noted <br /> at the point a new house is constructed the 30' setback froin the top of blltff wottld <br /> liave to be met. <br />
The URL can be used to link to this page
Your browser does not support the video tag.