Laserfiche WebLink
RHVAC-Resfdenttai�Light Conunercial HyAC l.oads P�ogram � �`` �* �Ide Software Development,lnc. ' <br /> �elt-Aite > ' ', _ LARKlN� �� <br /> Eapan�MN 55123 03-27-2003 + ''° 2 ,� ' Page 5 �, <br /> ' �:,..:s . �� ,..F _�> <br /> � .. '� " 't;4c � .�_ e , �Y��..h �4���e�++' sw.,a'�.� �;! L F4 �d'�Y rv� �'� y t-� . � <br /> S stem#4 Summa oads , _ � �:_ �. � � :: ,LL u .� � ,,.. ,,. .:, .� � k <br /> Y . n►�-. �. .� , : � . , . <br /> r� cr �"�; <br /> -- -'�=�x ;;,, ;.���,,-- , . -'`I "",�f'� <br /> Component Area Sen. Lat. Sen. Total <br /> Description _ Quan Loss Gain Gain __ Gain <br /> 3D Window Double Pane Low Emit Wood Frame 60 1,842 0 2,520 2,520 <br /> 11 E Door Metal Urethane Core 128 2,067 0 209 209 <br /> 12H Wali R-19+ 1/2"Gypsum Board(R-0.5) 832 4,243 0 429 429 <br /> 16H Ceiling R-38 Insulation 648 1,432 0 489 489 <br /> 22B Slab on Grade 1" Edge Insulation(R-5) 102 3,555 0 0 0 <br /> Subtotals for stnicture: 1,770 13,139 0 3,647 3,647 <br /> Active People: 0 0 0 0 0 <br /> tnactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 0 0 <br /> Lighting: 0 0 0 0 0 <br /> Ductwork: 0 0 0 0 0 <br /> Infiltration: Wirrter CFM: 54.0, Summer CFM: 10.8 188 4,899 -176 58 -118 <br /> Verrtilation: Winter CFM: 10.8, Summer CFM: 10.8 0 980 -176 58 -119 <br /> Sensible Gain Total: 3,763 <br /> Temperature S1'ving Multiplier: X1.00 <br /> S�em Load Totals:__ _ 19,018 -352 3,763 3,410 <br /> Check Fi ures "� ' i ' � ' - - �, ° �x:�.�, ��. <br /> I •q ��#�'"k!�(�'.� ''�0. Fi-�i.�,,v#�t� .n.:^a"�Tr` ,•'�,�;w3?'l&n.. ��:;'� t,t''•.*�.�,r:.�r ��` <br /> � Supply CFM: 241 CFM per square foot: 0.373 <br /> Square feet of room area: 648 Square feet per ton: 1,591.312 <br /> � ,� ,� �, � .� , . � � �a� <br /> _. . .. ,. � .. _ <br /> System Loads. �.��{ � . <br /> _. � k , , . , .. . . <br /> .... ..21M1...: !�� �#�.��a '4Hi��Yij''NP.�.! '�,1Y ... ... �'�:.1�^,'�N�`A .w��'�.^. �.�Lr494i:,:. !:. .� , $�..'...� .Y. 'R:ni�Y'Y... 'Y', ' � ,f�.ii <br /> Total heating required with outside air: 19,018 Btuh 19.018 MBH <br /> Total sensible gain: 3,763 Btuh 110 % <br /> Total latent gain: -352 Btuh -10 % <br /> Total cooling required with outside air: 3,410 Btuh 0.284 Tons(based on sensible+ laterrt) <br /> 0.407 Tons(based on 77%sensible capacity) <br /> ' Notes <br /> I <br /> Calculations are based on 7th edition of ACCA Manual J. I <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Thursday,March 27,2003 <br />