<br /> Component Area Sen. Lat. Sen. Total
<br /> Description _ Quan Loss Gain Gain __ Gain
<br /> 3D Window Double Pane Low Emit Wood Frame 60 1,842 0 2,520 2,520
<br /> 11 E Door Metal Urethane Core 128 2,067 0 209 209
<br /> 12H Wali R-19+ 1/2"Gypsum Board(R-0.5) 832 4,243 0 429 429
<br /> 16H Ceiling R-38 Insulation 648 1,432 0 489 489
<br /> 22B Slab on Grade 1" Edge Insulation(R-5) 102 3,555 0 0 0
<br /> Subtotals for stnicture: 1,770 13,139 0 3,647 3,647
<br /> Active People: 0 0 0 0 0
<br /> tnactive People: 0 0 0 0 0
<br /> Appliances: 0 0 0 0 0
<br /> Lighting: 0 0 0 0 0
<br /> Ductwork: 0 0 0 0 0
<br /> Infiltration: Wirrter CFM: 54.0, Summer CFM: 10.8 188 4,899 -176 58 -118
<br /> Verrtilation: Winter CFM: 10.8, Summer CFM: 10.8 0 980 -176 58 -119
<br /> Sensible Gain Total: 3,763
<br /> Temperature S1'ving Multiplier: X1.00
<br /> S�em Load Totals:__ _ 19,018 -352 3,763 3,410
<br /> Check Fi ures "� ' i ' � ' - - �, ° �x:�.�, ��.
<br /> I •q ��#�'"k!�(�'.� ''�0. Fi-�i.�,,v#�t� .n.:^a"�Tr` ,•'�,�;w3?'l&n.. ��:;'� t,t''•.*�.�,r:.�r ��`
<br /> � Supply CFM: 241 CFM per square foot: 0.373
<br /> Square feet of room area: 648 Square feet per ton: 1,591.312
<br /> � ,� ,� �, � .� , . � � �a�
<br /> _. . .. ,. � .. _
<br /> System Loads. �.��{ � .
<br /> _. � k , , . , .. . .
<br /> .... ..21M1...: !�� �#�.��a '4Hi��Yij''NP.�.! '�,1Y ... ... �'�:.1�^,'�N�`A .w��'�.^. �.�Lr494i:,:. !:. .� , $�..'...� .Y. 'R:ni�Y'Y... 'Y', ' � ,f�.ii
<br /> Total heating required with outside air: 19,018 Btuh 19.018 MBH
<br /> Total sensible gain: 3,763 Btuh 110 %
<br /> Total latent gain: -352 Btuh -10 %
<br /> Total cooling required with outside air: 3,410 Btuh 0.284 Tons(based on sensible+ laterrt)
<br /> 0.407 Tons(based on 77%sensible capacity)
<br /> ' Notes
<br /> I
<br /> Calculations are based on 7th edition of ACCA Manual J. I
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads.
<br /> Thursday,March 27,2003