<br /> Component Area Sen. Lat. Sen. Total
<br /> Description ____ Quan Loss Gain Gain Gain
<br /> 15G Wail 5'or More 8elow Grade 8/12" BIk+R-11 1,530 6,052 0 0 0
<br /> 16C Ceiling R-11 Insulation 648 5,246 0 2,680 2,680
<br /> 21A Basemt Floor 2'or More Below Grade 648 1,431 ____ 0 _ 0 _____ 0
<br /> Subtotals for structure: 2,826 12,729 0 2,680 2,680
<br /> Active People: 0 0 0 0 0
<br /> Inactive People: 0 0 0 0 0
<br /> Appliances: 0 0 0 0 0
<br /> ����yy; 0 0 0 0 0
<br /> Ductwork: 0 0 0 0 0
<br /> infiltration: Wir�ter CFM: 48.6, Summer CFM: 16.2 0 4,772 261 398 659
<br /> Ventilation: Winter CFM: 16.2, Summer CFM: 16.2 0 1,591 261 398 659
<br /> Sensible Gain Total: 3,476
<br /> Temperature Swing Multiplier. _ _ X1.00 _
<br /> S�stem Load Totals: 19,092 522 3,476 3,998
<br /> 'Check Figures; '' ����=i�=-
<br /> �� � � �
<br /> Supply CFM: 234 CFM per square foot: 0.362
<br /> Square feet of room area: 648 Square feet per ton: 1,722.701
<br /> ,. ....�::. : .. . .. , - _.::,.,. .. . ��,yrqij" ���Ctr�'�'�, 4 � r
<br /> System Lc,�au�. ��`� - ��h�
<br /> Total heating required with outside air. 19,092 Btuh 19.092 MBH
<br /> Total sensible gain: 3,476 Btuh 87 %
<br /> Total latent gain: 522 Btuh 13 %
<br /> Total cooling required with outside air: 3,998 Btuh 0.333 Tons(based on sensible+latent)
<br /> 0.376 Tons(based on 77%sensible capacity)
<br /> ;. � w�s.��� -
<br /> ..
<br /> ' ..: f{LL"a. !K�$xw�+� . .
<br /> t@S Y " � �Ir�:'.•
<br /> '�P o,�'w.�*��{�'S�E�ra���... '���''?J� -
<br /> Calculations are based on 7th edition of ACCA Manual J.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads.