<br /> System 1 Summary Loads _
<br /> Component Area Sen Lat Sen Total
<br /> Description Quan Loss Gain Gain Gain
<br /> LOW EE: Glazing-Builder Grade Low E Windows& 932.5 24,584 0 21,100 21,100
<br /> Sliding Door.33 U value .33 SHGC, u-value 0.31,
<br /> SHGC 0.29
<br /> 11J: Door-Metal- Fiberglass Core 41.8 2,131 0 677 677
<br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud 3687.9 21,316 0 4,615 4,615
<br /> cavity, no board insulation, siding finish,wood studs
<br /> 15B0-Ssf-4: Wall-Basement, , R-5 board exterior 70 536 0 0 0
<br /> insulation to footing, no interior finish, 4'floor depth
<br /> .1560-5sf-8: Wall-Basement, , R-5 board exterior 765 7,657 0 587 587
<br /> insulation to footing, no interior finish, 8'floor depth
<br /> RJ 10 Spray Foam: Wall-Frame, Custom, Closed Cell 738.2 6,275 0 1,855 1,855
<br /> R10 Spray Foam
<br /> 166-44: Roof/Ceiling-Under Attic with Insulation on Attic 1922.6 3,595 0 2,157 2,157
<br /> Floor(also use for Knee Walls and Partition
<br /> Ceilings),Vented Attic, No Radiant Barrier, Dark
<br /> Asphalt Shingles or Dark Metal, Tar and Gravel or
<br /> Membrane, R-44 insulation
<br /> 21A-20: Floor-Basement, Concrete slab, any thickness, 2 1425 3,270 0 0 0
<br /> or more feet below grade, no insulation below floor,
<br /> any floor cover, shortest side of floor slab is 20'wide
<br /> 20P-38: Floor-Over open crawl space or garage, Passive, 498.5 1,271 0 164 164
<br /> R-38_blanket insulatio_nLany cover_ _ _ _ __ _ _
<br /> _ _ _ _ __ _ __
<br /> Subtotals for structure: 70,635 0 31,155 31,155
<br /> People: 6 1,200 1,380 2,580
<br /> Equipment: 683 3,430 4,113
<br /> Lighting: 0 0 0
<br /> Ductwork: 5,393 1,578 1,541 3,118
<br /> Infiltration:Winter CFM: 97, Summer CFM: 0 8,785 0 0 0
<br /> Ventilation: Winter CFM: 140�_Summer CFM; 140 _ __ ___ _ 5,080 _ 3 847 . ___ 956_ _ 4,803_
<br /> System 1 Load Totals: 89,893 7,308 38,462 45,770
<br /> Check Fi ures
<br /> Supply CFM: 1,757 CFM Per Square ft.: 0.368
<br /> Square ft. of Room Area: 4,773 Square ft. Per Ton: 1,251
<br /> Volume (ft') of Cond. Space: 41,031
<br /> S stem Loads
<br /> Total Heating Required Including Ventilation Air: 89,893 Btuh 89.893 MBH
<br /> Total Sensible Gain: 38,462 Btuh 84 %
<br /> Total Latent Gain: 7,308 Btuh 16 %
<br /> Total Cooling Required Including Ventilation Air: 45,770 Btuh 3.81 Tons (Based On Sensible+ Latent)
<br /> Notes
<br /> Rhvac is an ACCA approved Manuai J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> C:\...\Gonyea 790 Brown Rd Long Lake.rh9 Tuesday, January 13, 2015, 8:36 AM