<br /> Rhvac-Residentiai&Light Commercial HVAC Loads Elite Software Development,inc.
<br /> Sabre Plumbinq&Heatinq � 790 Brown Rd Lonq Lake
<br /> PI mouth MN 55447 �1� Pa e 3
<br /> Load Preview Report -�
<br /> , �
<br /> � , �
<br /> � Net� ft�� Senl Lat; Net� Senj Hts CIS Act Duct
<br /> Scope Ton. ITon; Area j Gain i Gain( Gain� Loss I 9 9 Size
<br /> _ � i i_� _ CFM CFM CFM
<br /> Building 3.81 1,251 4,773 38,462 7,308 45,770 89,893 1,135 1,757 1,757
<br /> System 1 3 81 1,251 4,773 38,462 7,308 45,770 89,893 1,135 1,757 1.757 18x18
<br /> Ventilation 956 3,847 4,803 5,080
<br /> Duct Latent 1,578 1,578
<br /> Zone 1 -Clg 24°/.Htg:32% 1,425 10,325 0 10,325 26,967 361 484 484 9x11
<br /> 1-Basement 1,425 10,325 0 10,325 26,967 361 484 484 5--6
<br /> Zone 2-Clg:41%,Htg:31% 1,425 17,891 683 18,574 26,378 353 838 838 10x16
<br /> 2-Main floor 1,425 17,891 683 18,574 26,378 353 838 838 8--6
<br /> Zone 3-Cig 35%,Htg,37% 1,923 15,184 1,200 16,384 31,468 421 711 711 10x14
<br /> 3-2nd floor&Bonus 1,923 15,184 1,200 16,384 31,468 421 711 711 7--6
<br /> Sum of room airtlows may be greater than system airtlow because
<br /> s stem has multi le zones.