b)For a tank soil cover depth that is greater than 2.0 feet and up to 4.0 feet(600 to if needed.Long-term groundwater control measures such as underdrains and <br /> 1,200 mm),suitable soil textures include: interceptor trenches may be sensible if the site is amenable to construction of a <br /> control system and such systems are not prohibited by regulation or law,and the tank <br /> ���°�<�^� location is not subject to flooding.Properly installed underdrains and groundwater <br /> NEv <br /> �u��uab�< 'i interceptor trenches may prevent the need for tank buoyancy controi measures. <br /> eo Sui�aMe If santl z30•b I <br /> arM dilatant <br /> 20 <br /> I '� s°"a°'° � INSTALLING UNDER SHALLOW GROUNDWATER CONDITIONS <br /> Arkansas onty: <br /> Fo�sne:w�m 9,ea�e�ma�wr�a���e Buoyancy control measures may be required if the Infittrator tank is to be installed <br /> �o J0 Gay soil,bacMill shall be septic gravel <br /> o�s�m�ia�a„9�ia�s,o�e.saea,a���n with less than 12 inches(300 mm)of soil backfill cover,and where the water level <br /> °° �°,-,�z�^�^e5 outside the tank has the potential to rise 30 inches(750 mm)or more above the <br /> ,e,«�, �ti,,� so pe1CB�,51LT elevation of the tank bottom.Otherwise,no control measures are required(see <br /> s���° Table 1).The need for buoyancy control measures must be determined based on <br /> �„ snr�o cur <br /> =�A backfill cover depth and height of water outside of tank above the tank bottom <br /> s��r�� <br /> ��^� according to Table 1.Refer to InfiRrator IM-and TW-Series Tank Buoyancy Control <br /> SAN CLA <br /> � AM Guidance document for more information. <br /> °^ s��_�oa., Table 1:Tank models'and conditions requiring buoyancy control� <br /> � <br /> nNo �o s��1 Soil cover depth above tank' <br /> iw>-:sauo w+ iooisi�T Waterheightabove <br /> �o ao �� �� zo ,o tank bottom 6 in(150 mm)to Above 12 in <br /> Pd<<e��i.Fr,c 5 oa� s od 12 in(300 mm) (300 mm) <br /> 3 Above outlet Do not install Do not install <br /> pipe saddle <br /> 3. Backfill should not have stones greater than 3 inches(75 mm)in diameter or <br /> excessive clods that do not break apart during placement and compaction. 3s in(soo mm)to4 qli models None <br /> Backfill must be capable of occupying the spaces between the tank ribs and outlet pipe saddle <br /> beneath the haunches. 3o in(75o mm)to Ail models except None <br /> Note:Rounded screened aggregate(e.g.,pea gravel)is not a suitable 36 in(90o mm) IM-540 and IM-1060 <br /> b2Ckfill. Less than 30 in None None <br /> 4. Standard field soil classification methods shall be used to determine the soil (�5o mm) <br /> t2XtUfel CIeSS. 1.IM-540,IM-1060.TW-1250,TW-1500,and IM-1530. <br /> Note:Under most circumstances,the determination of soil dilatancy will 2.See Infiltrator IM-and TW-Series Tank Buoyancy Control Guidance for detailed information on <br /> not be required.Dilatancy shall be determined in the field using a test that the use of controls. <br /> does not require specialized equipment,pe�ASTM D2488,Section 14.3. 3.No controls are required for soil cover depths exceeding 12 in(300 mm). <br /> COIII lete instructions can be found at www.infiltrators stems.com 4•The tank shall not be installed where the water level outside the tank exceeds the height of the <br /> P Y outlet pipe saddle.Follow Table 4 guidelines. <br /> 5. Place and compact soil by walking-in beneath the haunches of the tank. <br /> 6. Place backfill around the four sidewalls in an afternating manner,so that the backfill INSTALLING RISERS <br /> height along the four sidewalls is maintained within a 12-inch(300-mm)tolerance. 1.Compatible risers include 24-inch(600 mm)diameter products such as <br /> 7. Do not backfill top of tank before sidewalls are completely backfilled. the Infiltrator TW-Riser,EZset by Infiltrator,PolyLok�,Inc.,and Tuf-TiteO <br /> 8. Continue to place backfill along the sidewalls in 12-inch(300-mm)lifts.Place Corporation,in addition to 24-inch(600 mm)diameter corrugated HDPE and <br /> backfill between the ribs on the sidewalls such that the space between the IPEX URra RibO PVC pipe.Follow Infiltrator's IM-and TW-Series Tank Riser <br /> ribs is completely filled with soil. Connection Guidance. <br /> 9. Compact backfill material either by walking-in,hand tamping or mechanical 2•In Oregon only,watertightness testing shall include filling with water at least 2 <br /> compaction(includes backhoe bucket).If inechanical compaction is inches above riser connection,with no more than 1 gallon leakage per 24 hours, <br /> used,such as a walk-behind tamper or backhoe bucket,a single pass is Per OAR 340-073-0025(3). <br /> recommended.Compact each lift prior to placement of next lift.Compact INSTALLING PUMPS AND RELATED EQUIPMENT <br /> backfill from tank walls to excavation sidewalls. Pumps may be supported on a stable,level 16x16-inch(400x400-mm)platform <br /> 10.Complete backfilling and grade the area. positioned on the bottom of the tank.One 16x16-inch block or two 8x16-inch(200 <br /> 11.A minimum 6-inch(150-mm)depth of suitable soil must be placed over the -mm x 400-mm)side-by-side blocks may be used.Limit block height to account for <br /> top of the tank.The balance of backfill placed to finish grade above the tank pump height and liquid levels during pump cycles.Block(s)should be placed below <br /> may be either suitable or unsuitable soil. an access opening and level upon the tank bottom.For two blocks,orient them <br /> 12.Establish a strong stand of erosion-resistant vegetation. perpendicular to ribs on the tank bottom,if present,for stability. <br /> Note:Grade to prevent the backfilled excavation from filling with surface Installation of products such as electrical conduit and wiring,pumps,water level <br /> runoff.lf the water level in the backfilled excavation exceeds the height of control equipment,valves,siphon equipment,etc.shall be in accordance with the <br /> the outlet pipe saddle,tank structural integrity may be compromised. product manufacturer's instructions and compliant with applicable state or local rules <br /> and regulations.Appurtenances shall be fastened to the tank riser system and not the <br /> MouNo sncKFi��Foa--, —MiNiMUM e•soi�coveR tank body or access opening rim.Where possible,appurtenances shall be installed <br /> POSITNE DRPJNAGE ' to facilitate maintenance and repair access via the tank access openings. <br /> ����\�����i��i�������� ��������?���`�����\�\�\���e��_ Note:Prefabricated pump vaults may be installed. <br /> %i i�i ii r- , ���i.���` �%���; <br /> �������� � ������ <br /> � a � GENERAL SPECIFICATIONS <br /> ��! � 3"(/5 mm) •Failure to comply with installation instructions will void warranty. <br /> PL4CE SOIL � <br /> BETWEEN RIBS �������.�.� � . � ���� PMnRiIaE size •Prior to ground disturbance,check for subsurface obstructions and utilities in <br /> ���i� , ���` PacEsoi�iN conformance with applicable requirements. <br /> COMPACTED I II � <br /> SUITABLE NATIVE � � � �.i'i% �2"(300 mm) •Operating water temperature shall be less than 100°F(40°C). <br /> SOILBACKFILL �� �� � �� � �u� UFTSAND •In cold conditions,handle and backfill tank with care to revent im act dama e. <br /> � �� ' VV�j COMPACT P P J <br /> � i������`�������f,�y������������O�i�����y����� •Tanks are not fire resistant.Store away from ignition sources. <br /> \,�i���/� ���/�����.� ���� {�/��,/.� —PLACEANDCOMPACT <br /> SOILBENEATHHAUNCHES •Removal of structural bulkheads is prohibited;removal of locking clips on the IM- <br /> ie°-as•�asasoomm� �----{ •un-iososnoWn ro<<ere�e��e Series tank mid-seam connection is also prohibited. <br /> OR SIZEDAS NECESSARV •Onl suitable for otable a lications if the tank bears the NSF/ANSI 61 <br /> TO ENSURE PROPER BACKFILLING PROCEDURE y p PP <br /> certification mark.Otherwise,tank is recommended for use in septic,rainwater/ <br /> SHORT AND LONG-TERM GROUNDWATER CONTROL stormwater storage,holding,and pump applications,or other non-potable uses. <br /> It may be necessary to implement groundwater control measures during tank •Infiltrator tanks are designed for installation underground. <br /> installation.Maintain dry conditions by expanding the excavation to create a short- •Contact Infiltrator Systems for above-ground use requirements. <br /> term groundwater collection sump for temporary placement of a dewatering pump <br /> ��.. :�� <br />