My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2015-00798 - COO with Permit info
Orono
>
Property Files
>
Street Address
>
C
>
Cobblestone Court
>
2460 Cobblestone Court - 33-118-23-11-0081
>
Permits/Inspections
>
2015-00798 - COO with Permit info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:44:32 PM
Creation date
4/20/2016 10:35:51 AM
Metadata
Fields
Template:
x Address Old
House Number
2460
Street Name
Cobblestone
Street Type
Court
Address
2460 Cobblestone Court
Document Type
Permits/Inspections
PIN
3311823110081
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m�������� <br /> . New Construction Energy Code Compliance Certificate :�,.; , ,� � ���- <br /> Per Nl 1 Ct.B Building Certificate.A building certificate shall be posted in a permanently visible location inside Date Certificate Posted `" " ' `��'� <br /> ' the budding. The certificate shall be completed by the builder and shall list information and values of <br /> �:omponentslistedinTableN1101.8. ����� p���O <br /> Mailing Address of the Dwelling or Dwelling Unit City ' �'����J <br /> 2460 Cobblestone Court Orono �ogo here <br /> Name of Residential Contractar MY License Vumber <br /> Wooddale Builders BC002926 <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type: Check All That Apply )( Passive(No Fan) <br /> �o � <br /> 7 � F � Active(With fan and monometer or <br /> ����� �� � � <br /> � >, other system rnonitoring device) <br /> �a � � — � o°, :3 <br /> o a. 3 � �j ^ o � <br /> � � d � `e U � �o 'c <br /> � Ca f� � � � � �, <br /> � .. o �; o a� w � o <br /> Insulation Location � .� z � � v � � w .... <br /> ca o � � <br /> � � � � � � � � b � <br /> :a ca � <br /> F�- � z w w w° w° � u; x Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-15 X R10 Ext. & R5 Int. <br /> Perimeter of Slab on Grade X <br /> Rim Joist(Foundation) R-20 X Spray Foam <br /> Rim Joist(1"Floor+) X <br /> Wall R-21 X <br /> Ceiling,flat R-49 X <br /> Ceiling,vaulted R-49 X <br /> Bay Windows or canrilevered areas R-38 X AISo 3/4" Foam below <br /> Bonus room over garage X <br /> Describe other iosulated areas <br /> Windows 8 Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(exc[udes skylights and one door)U: 0.31 X Not applicable,all ducts located i�conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.33 <br /> MECHANICAL SYSTEMS Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type Natural Gas Electric Electric Pass��e <br /> �tanufacturer Rheem Rheem Rheem Powered <br /> Interlocked with e�chaust device. <br /> vlode► R92PA0601317MSA 82v50-2 13AJN36A01 Describe: <br /> Input in 56,000 Capac�ry in so ourput in 3 Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> Heat Loss: 46,774 Heat 31,435 Location of duct or system: <br /> Structure's Calculated Gain: <br /> AFCJE or 92 SEER: 13 <br /> HSPF% <br /> Calculated 34,200 <br /> Efficienc cooling load: Cfm's <br /> "round duct OR <br /> Mechanical Ventilation Sysfem "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two fumaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up fumace): X Not required per mech.code <br /> Select Type Passive <br /> Heat Recover Ventilator(HR� Capaciry in cfms: Low: 75 High: 150 Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: Low: High: Location of duct or system: <br /> Continuous e�austing fan(s)rated capacity in cfms: <br /> L,ocation of fan(s),describe: Bathroom Cfm's <br /> Capaciry continuous ventilation rate in cfins: 63 CFM "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfrns: 125 CFM "metal duct <br /> Created by BAM version 052009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.