Modei F1 Res 44 & 58 Recessed Horizontal <br /> Sidewall Sprinkler Residential recessed pendent sprinklers shall be Reliable <br /> Use description for the Model F1 Res 58 horizontal [Model F1 Res 76 Recessed PendenUF1] [Model F1 Res <br /> sidewall sprinkler with the following modifications: Re- 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed <br /> place "horizontal sidewall sprinkler" with "recessed hori- Pendent/FP] SIN R7618(Bulletin 135). <br /> zontal sprinkler." Add: Recessed escutcheon assembly Model F1 Res 76 CCP Pendent (Concealed) <br /> shall be a steel, two-piece escutcheon with Y2" adjust- Sprinklers shall be [cULus Listed] low flow residential <br /> ment (Model F2). Standard finish shall be [brass][bright concealed sprinklers engineered to provide a minimum <br /> chrome] [white painted] [Special finish- specify]. Resi- design density of 0.10 gpm/ftz over the listed coverage <br /> dential recessed horizontal sidewall sprinklers shall be area. Listed flows as specified by the manufacturer's <br /> Reliable Model F1 Res 58/F2, SIN R3513{Bulletin 135). technical data sheets are to be used. Residential sprin- <br /> Model Fi Res 76 Pendent klers shall be installed in conformance with the manufac- <br /> Sprinklers shall be [cULus Listed] low flow resi- turer's installation guidelines and the applicable installa- <br /> dential pendent sprinklers engineered to provide a tion standard. Sprinkler frame and deflector shall be of <br /> minimum design density of 0.10 gpm/ft? over the list- bronze frame construction having a 3/a"N�T thread. Water <br /> ed coverage area. Listed flows as specified by the seal assembly shall consist of a Teflon-coated Belleville <br /> manufacturer's technical data sheets are to be used. spring washer with machined or cold head cup with 3 <br /> Residential sprinklers shall be installed in conformance mm glass bulb containing no plastic parts, and having a <br /> with the man�facturer's installation guidelines and the temperature rating of 155°F (68°C). Cover plate assem- <br /> applicable installation standard. Sprinkler frame and bly shall consist of a brass cover plate and copper alloy <br /> deflector shall be of bronze frame construction having retainer flange. Method of attaching the cover plate to the <br /> a�4" NPT thread. Water seal assembly shall consist of sprinkler cup shall be a push-on and thread-off design <br /> a Teflon-coated Belleville spring washer with machined allowing a '/z" cover plate adjustment. Cover plate tem- <br /> or cold head cup with 3 mm glass bulb containing no perature rating shall be 135"F (57°C). A plastic protec- <br /> plastic parts, and having a temperature rating of[155°F tive cap shall be provided and factory installed inside the <br /> (68°C)] [175°F(79°C)]. Sprinklers shall have a nominal sprinkler cup to protect the sprinkler from damage, which <br /> K-factor of 7.6. Standard finish: [Bronze] [Chrome-plat- could occur during construction before the cover plate <br /> ed] [White Polyester] [Special finish specify]. Residen- is installed. Standard cover plate finish: [White] [Custom <br /> tial pendent sprinklers shall be Reliable Model F1 Res Color-specify]. ]. Concealed pendent sprinklers shall be <br /> 76, SIN R7618(Bulletin 135). Reliable Model F1 Res 76 CCP, SIN R7618(Bulletin 135). <br /> Model F1 Res 76 Recessed Pendent/F1, Finishes�'> <br /> Model Fi Res 76 Recessed Pendent/F2, Standard Finishes <br /> Model Fi Res 76 Recessed Pendent/FP Sprinkler Fi, F2, FP Escutcheons <br /> Sprinklers shall be [cULus Listed] low flow residen- <br /> ----..........Bronze----..._..---.....------______ Brass <br /> tial recessed pendent sprinklers engineered to provide Chrome Plated Bright Chrome Plated <br /> a minimum design densiry of 0.10 gpm/ft�over the listed wn�te Poiyester coatea��� wr,��e Pa�nted � <br /> coverage area. Listed flows as specified by the manu- Special Application Finishes <br /> facturer's technical data sheets are to be used. Residen- <br /> tial sprinklers shall be installed in conformance with the Sprinkler I F1,F2,FP Escutcheons <br /> manufacturer's installation guidelines and the applieable [lectroless Nickel �iect�oiess Nic�ei <br /> installation standard. Sprinkler frame and deflector shall PTFE(Teflon�')"'' PTFE(Teflon")" <br /> Bright Brass Bright Brass <br /> be of bronze frame construction having a�j/" NPT thread. �ia�k Piated �ia�k�i3red <br /> Water seal assembly shall consist of a Teflon-coated Bel- Bia�k�a�nt �i�ok�a�nt <br /> leville spring washer with machined or cold head cup with Off White Off White <br /> 3 mm glass bulb containing no plastic parts, and having Chrome Dull cnrome�uii <br /> a temperature rating of [155°F (68°C)] [175'F (79°C)]. "'Other finishes and colors are available on special order. <br /> Consult factory for details, � <br /> Sprinklers shall have a nominal K-factor of 7.6. Standard cu�us i�sted cor�os�on�es�stant. <br /> finish:[Bronze][Chrome-plated][White Polyester][Special <br /> finish-specify]. Recessed escutcheon assembly shall be Ordering Information <br /> a steel, two-piece escutcheon [with '/z" adjustment(Mod- Specify: <br /> el F2}] [with %a" adjustment (Model F1)] [of push-on and 1. Sprinkler Model <br /> thread off design with '/z" adjustment (Model FP)]. Stan- 2. Sprinkler Type <br /> dard finish shall be[brass][bright chrome][white painted]. 3, Temperature Rating <br /> 4. Sprinkler Finish <br /> � �DuPont fiegistered Trademark 5. Escutcheon Finish <br /> 13. <br />