Model F1 Res 30,49&58 Rece.ssed Pendent/Fi, <br /> Model F1 Res 30,49&58 Rece.Ssed Pendent/F2, plate adjustment. Cover plate temperature r: ting shall be <br /> Model Fi Res 30,49&58 Recessed Pendent/FP �35°F(57°C). A plastic protective cap shall be provided <br /> Sprinklers shall be[cULus Listed] [New York City MEA and factory installed inside the sprinkler cup to protect <br /> Approved (258-93-E)] low flow residential recessed pen- the sprinkler from damage, which could occur during <br /> dent sprinklers engineered to provide a minimum design construction before the cover plate is installed. Standard <br /> densiry of 0.10 gpm/ftz over the listed coverage area. cover plate finish: [White][Custom Color--specify]. ].Con- <br /> Listed flows as specified by the manufacturer's technical cealed pendent sprinklers shall be Reliable Model F1 Res <br /> data sheets are to be used. Residential sprinklers shall 49&58 CCP, SIN R3516&R3513(Bulletin 135). <br /> be installed in conformance with the manufacturer's instal- Model F1 Res 44, F1 Res 58 Horizontal <br /> lation guidelines and the applicable installation standard. Sidewall, F1 Res 58 HSWX & KRes58 HSWX <br /> Where pendent residential sprinklers are installed under Residential Sprinkler Specifications <br /> sloped ceilings having a pitch from [4/12] to [8/12], the <br /> sprinklers shall be listed for such use. Deflector-to-ceiling Sprinklers shall be [cULus Listed] low flow residen- <br /> distance listing shall be 1"to 8"maximum.Sprinkler frame tial horizontal sidewall sprinklers engineered to pro- <br /> and deflector shall be of bronze frame construction hav- vide a minimum design density of 0.10 gpm/ft over <br /> ing a'/z" NPT thread. Water seal assembly shall consist of the listed coverage area, Listed flows as specified <br /> a Teflon* coated Belleville spring washer with top-loaded by the manufacturer's technical data sheets are to be <br /> ; extruded or cold head cup with 3 mm glass bulb contain- used. Residential sprinklers shall be installed in con- <br /> ing no plastic parts, and having a temperature rating of formance with the manufacturer's installation guide- <br /> [155°F (68°C)] (175°F (79°C)]. Sprinklers shall have a lines and the applicable installation standard. Where <br /> nominal K-factor of 4.9 (70). Standard finish: [Bronze] horizontal sidewall residential sprinklers are installed <br /> [Chrome-plated] [White Polyester] [Special finish- spec- under sloped ceilings having a pitch from [4/12] to <br /> ify]. Recessed escutcheon assembly shall be a steel, L8��2],the sprinklers shall be listed for such use.Sprin- <br /> two-piece escutcheon [with %z" adjustment (Model F2)] kler frame and deflector shall be of bronzE frame con- <br /> [with 3/n" adjustment (Model F1)] [of push-on and thread struction having a %" NPT thread. Water seal assem- <br /> off design with Yz°adjustment(Model FP)].Standard finish bly shall consist of a Teflon-coated Belleville spring <br /> shall be[brass][bright chrome) [white painted]. Residen- Washer with top-loaded extruded or cold head cup <br /> tial recessed pendent sprinklers shall be Reliable [Model With 3 mm glass bulb containing no plastic parts, and <br /> F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res having a temperature rating of [155°F (68°C)] [175°F <br /> 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 �79�C)]. The solder element (Link) version, the water <br /> Recessed Pendent/FP]SIN R3516&R3513(Bulletin 135). seal consist of a cap with a bellville spring washer and <br /> a temperature rating of 165°F (74°C). The recessed <br /> Model F1 Res 30, 49 & 58 CCP Pendent assembly forthe HSWX(Bulb& Link) should be a steel <br /> (Concealed) two pieces escutcheon with 1/2" adjustment (Model <br /> Sprinklers shall be[cULus Listed] [New York Ciry MEA F2}standard finish should be Bright Chrome and white <br /> Approved (258-93-E}) low flow residential concealed painted. The F1 Res 58 HSW is also available with low <br /> sprinklers engineered to provide a minimum design den- lead frame. F1 Res 58 HSW and HSWX sprinklers shall <br /> siry of 0.10 gpm/ft�over the listed coverage area. Listed have a nominal K Factor of 5.8 and F1 Res 44 a nomi- <br /> flows as specified by the manufacturer's technical data nal K factor of 4.4. Standard finish: [Bronze] [Chrome- <br /> sheets are to be used. Residential sprinklers shall be in- plated] [White Polyester] [Special finish- specify]. <br /> stalled in conformance with the manufacturer's installa- Residential horizontal sidewall sprinklers shall be Reli- <br /> tion guidelines and the applicable installation standard. able Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & <br /> Where pendent residential sprinklers are installed under Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 <br /> sloped ceilings having a pitch from [4/12] to [8/12], the (Bulletin 135). <br /> sprinklers shall be listed for such use. Sprinkler frame and <br /> deflector shall be of bronze frame construction having a <br /> %" NPT thread, Water seal assembly shall consist of a <br /> � Teflon' coated Belleville spring washer with top-loaded <br /> extruded or cold head cup with 3 mm glass bulb contain- <br /> ing no plastic parts, and having a temperature rating of <br /> 155°F (68°C). Cover plate assembly shall consist of a <br /> brass cover plate and copper alloy retainer flange. Meth- <br /> od of attaching the cover plate to the sprinkler cup shall <br /> be a push-on and thread-off design allowing a '/�" cover <br /> I "DuPont Registered Trademark <br /> 12. <br />