2007-P10689 - office remodel
Orono
>
Property Files
>
Street Address
>
B
>
Blaine Avenue
>
2389 Blaine Avenue - 17-117-23-34-0012
>
Permits/Inspections
>
2007-P10689 - office remodel
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:37:15 PM
Creation date
4/18/2016 2:26:43 PM
Metadata
Fields
Template:
x Address Old
House Number
2389
Street Name
Blaine
Street Type
Avenue
Address
2389 Blaine Avenue
Document Type
Permits/Inspections
PIN
1711723340012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � Revised 12/11/06 <br /> ELECTRICAL AND LdW VOLTAGE <br /> • GENERAL <br /> a) Electrical to indude new outlets per Exhibit A, including dedicated isolated grou�d outlets as <br /> shown on floor plan. <br /> b) Existi�g outlets can be used to meet the requirements for general-purpose outlets only. �lectrical <br /> outlets to be installed where shown on the fumiture plan at 18"above finished floor unless an <br /> existing deviCe is already within 36'of the desired location. <br /> c) I�stall or replace all outlet covers with white faceplates or to match existing.Confinn color with <br /> designe�if other than white. <br /> dy The computer equipment for this office is sensitive to high electromagnetic interfere�ce(EMI).We <br /> recommend that the ambient EMI in the office not exceed 2 Mg. <br /> e) Landlord respor►sible for setting up utilities or providing temporary electncal in space that is new <br /> construction or space that is being subdivided. Electrical contractor to verify existing elecVical <br /> panel will accommodate Jones�equirements. <br /> f) ElectMcfan to Instal13/4•' (.75")oonduit 8 box with pull string or mud rfng at all locations <br /> (see section 4 below)wlth low voltage communication connectans. Install(1)single gang <br /> box at each location indicated on the drawing with a triangle('�'). DO NOT install a double <br /> gang box at Iocations where(2)symbols are sdJacent. Refer to leggr�d cn sheet 2 of <br /> Exhibit A for locations aF double gang boxes. if conduit is�ot going to be installed,please <br /> contact DeSigner at 800-8246525 immediately. <br /> g) Additio�ally electrician to instail two-'/."(,75")conduit it�to single ga�g electrical boxes fo� <br /> incoming phone jacks�RJ11)within 7'-0"of BOC per Detail A in section 4. Contrsctor to <br /> pull the number of Cat6e phone lines indicated on sheet 2 of 3 of the drawings. <br /> 1. DEDICATED OUTETS <br /> Oefinition: A dedicated ouNet is wired direcUy to the main power distribution panel through a <br /> designated(dedicated)circuit breaker.An isolated grou�d is a ground wire connected at only one <br /> c�mmon point in the electriicad breaker pan�.The dedicated ouUets are color coded to distinguish <br /> them from general-purpose outlets.Only the faser printer and PES/DIU (BOC)should be plugged into <br /> them).7he technical information for these outlets is as follows� <br /> a) Two Dedicated Isolated Grou�d ouUets(simple:not duotex)reauired for the Laser Pnnter a�d <br /> BOC(S�e Legend on Sheet 2 of Exhibit A). <br /> b) Each to be standard 3-prong, 120 volt, 20 amp,dedicated isolated ground circuit. <br /> c) Each to be SIMPLEX, O�'dnpe color coded receptacle(NEMA type 5-15 R/1G ouUet, GE5362-IG <br /> or equivalent). <br /> d) All grounds must have same grcund potential. <br /> Z.GENERAL PURPOSE OUTLETS(Should be placed as shown on dr�wing) <br /> a.) One(1)quad ouUet at NNCR location. <br /> b.) At tetminals and other office equipmerrt as shown on the plan_ <br /> c.) All outlets to be 110 volt standard 3-nrons�outletg that meet state and bcal requirements(NEMA <br /> type 5-15R).The grounding conductors fur the budd'mg's circuits should be referenced to the point <br /> of'2ero currenY within the electrical supply system,which is where the neutral and ground far the <br /> system are fied together. <br /> 3. LIGHTING <br /> a.) Should be even and have a minimum of 6p-foot candles at desktop height.Alt lighting should be <br /> fully operational and in good condition. <br /> b.) At all bcations where existing flxtures are to be retamped,install F28T8/UMX/EC0 lamps <br /> with GE ULTRAMAX ballast or equlvalent, For ordoring,questions,or additional <br /> information regardi�g GE lamps,contact Lance Leonard�t GE Supply,63�305-2521. <br /> c.) Please verify that all lenses and lamps are consistent in cobr. lenses to be fi�of stains. <br /> d.) A switch should occur at each egress door,and shall be 3-way if applicable_ <br /> e.) In rooms 101 and 103, hard wire one light fixture to remain on at all times. Lights should be <br /> oriented to allow illumination of interior common areas,from exterior, during evening hours. (This <br /> item to be adjusted in Title 24 regions to meet Iocal energy requirements). <br /> f.) Please verify emergency/exit lighting meets code requi�ements. If not, please provide cost of new <br /> equipment and instalfation of such to meet code. <br /> 5 <br /> . I� a <br />