Laserfiche WebLink
ESR-1715 I Most�dely Accepted and Trusted Page 2 of 5 <br /> building. In jurisdictions using the UBC, two layers of Limited to a minimum 15/32-inch-thick (11.9 mm) code- <br /> nonperforated, Type 15 felt applied shingle-fashion must complying plywood deck; one layer of minimum '/4-inch <br /> be installed and solid-cemented together with approved (6.35 mm) G-P Gypsum DensDeck�mechanically fastened <br /> cementing material between the plies, and must extend with all joints staggered a minimum of 6 inches from the <br /> from the eave up the roof to a line 36 inches inside the plywood joints; and one ply of Type 30 felt. <br /> exterior wall line of the building. Limited to a minimum 15/32-inch (11.9 mm) plywood or <br /> 3.6 Flashing: APA rated series OSB deck with one or more plies of Elk <br /> Flashing materials must be copper or stainless steel with a VersashieldT"' or Atlas FR 50 underlayment. <br /> minimum thickness as prescribed in Section 15072.9 of 4.5.2 Class C: To achieve a Class C rating, EcoStarT"' <br /> the IBC, Section R905.2.8 of the IRC, or Sections 1508 Majestic Slate and Seneca Cedar Shake roof tiles must be <br /> and 1509 of the UBC, as applicable. installed as noted in Sections 4.1 through 4.4. <br /> 4.0 INSTALLATION <br /> 4.6 Reroofing: <br /> 4.1 General: <br /> Existing roof coverings must be removed and the Majestic <br /> Installation of EcoStarT"' Majestic Slate and Seneca Cedar Slate or Seneca Cedar Shake products must be installed <br /> Shake roof tiles must comply with this report and the as described for new construction in Sections 4.1 through <br /> manufacturer's published installation instructions. The 4.5. <br /> manufacturer's published installation instructions must be <br /> available at the jobsite at all times during installation. 4.7 Wind Resistance: <br /> These roofing tiles must only be applied to roofs with The allowable wind uplift pressure for EcoStarT"' Majestic <br /> ventilation complying with Section 1503.5 of the IBC, Slate and Seneca Cedar Shake roof tiles as part of <br /> Section R806 of the IRC, or Section 1505.3 of the UBC, as assemblies are noted in Table 1. <br /> applicable, on solid wood, plywood or OSB sheathing, <br /> complying with the applicable code, and on roofs having a 5.0 CONDITIONS OF USE <br /> minimum slope of 3:12 (25%) for Majestic Slate Roof Tile <br /> products and 4:12 (33%) for Seneca Cedar Shake Roof The EcoStarT"' Majestic Slate and Seneca Cedar Shake <br /> Tile products, and a maximum slope of 21:12(175°/o). roof tiles described in this report complies with, or is a <br /> suitabie alternative to what is specified in, those codes <br /> 4.2 Underlayment Application: listed in Section 1.0 of this report, subject to the following <br /> Severe climate underlayment complying with Section 3.5.2 conditions. <br /> must be installed at all valleys, eaves, rake edges, vertical 5.1 Installation must comply with this report and the <br /> flashing and areas where venting is to be installed. A manufacturer's published installation instructions. In <br /> single layer of underlayment complying with Section 3.5.1 <br /> must be applied over the remaining roof deck area. the event of a conflict between the manufacturer's <br /> instructions and this report, the instructions in this <br /> 4.3 Shingle Application: report must govern. <br /> Fasteners must be in accordance with Section 3.4. 5.2 Wind uplift pressure on any area, including edge and <br /> Beginning at the eave, one layer of tile is installed with two corner zones, must not exceed the allowable wind <br /> nails per tile(in a location shown on the tiles). This layer of pressure given in Table 1. <br /> tile becomes the starter row. A second layer is similarly <br /> fastened directly over the first row (no exposure) with a The allowable wind uplift pressures given in Table 1 <br /> horizontal offset of a half tile. Subsequent tiles are similarly are for the roof covering only. The deck and framing <br /> installed up the roof slope with a 6- or 7-inch (152 or to which the covering is attached must be designed <br /> 178 mm)exposure for Majestic Slate Roof Tile products or for the applicable components and cladding wind <br /> a 7-or 8-inch(178 or 203 mm)exposure for Seneca Cedar loads in accordance with the applicable code. Where <br /> Shake Roof Tile products, and a minimum 3/8-inch required by the applicable code, the calculations must <br /> (9.5 mm) and maximum '/2-inch (13 mm) gap between be sealed by a registered design professional, and <br /> tiles. See Figure 3 for further details. presented to the code official for approval. <br /> 4.4 Hip and Ridge Units: 5.3 The tiles are manufactured in Holland, New York <br /> Prior to installation of the hip and ridge tiles field under a quality control program with inspections by <br /> underlayment, complying with Section 3.5.1, is installed Underwriters Laboratories Inc. (AA-668). <br /> so that it laps the peak of the hip or ridge a minimum of 6.0 EVIDENCE SUBMITTED <br /> 4 inches (102 mm) each way, resulting in a double layer <br /> of underlayment when a ridge vent is not used. If a ridge Data in accordance with the ICC-ES Acceptance Criteria <br /> vent is used, the underlayment is terminated at the ridge for Special Roofing Systems(AC07), dated April 2007. <br /> vent in accordance with the vent manufacturer's �0 IDENTIFICATION <br /> recommendations. Hip and ridge tiles are installed with a <br /> 6-inch (152 mm) exposure, using two fasteners located as Each tile must be identified with the EcoStarT"' name and <br /> shown in Figure 2. Fasteners attaching hip and ridge phone number, the product name (Majestic Slate or <br /> tiles must be long enough to penetrate a minimum of Seneca Cedar Shake) and the production date. Each <br /> 3/a inch (19.1 mm) into or through the sheathing, whichever bundle of tile must be labeled with the number of tiles in <br /> is less. the bundle, color of the tile, the evaluation report number <br /> 4.5 Fire Classification: (ESR-1715) and the name of the inspection agency <br /> (Underwriters Laboratories Inc.). Each pallet of bundles <br /> 4.5.1 Class A: To achieve a Class A rating, EcoStarT"^ (Majestic Slate or Seneca Cedar Shake)must be identified <br /> Majestic Slate and Seneca Cedar Shake roof coverings with the product name, production code, and color. <br /> must be installed in accordance with Sections 4.1 through <br /> 4.4 and either(a)or(b), below: <br />