My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Wall section specs - hse?garage?
Orono
>
Property Files
>
Street Address
>
C
>
Casco Point Road
>
2618 Casco Point Road - 20-117-23-24-0038
>
Land Use
>
Wall section specs - hse?garage?
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:55:30 PM
Creation date
3/9/2016 1:48:08 PM
Metadata
Fields
Template:
x Address Old
House Number
2618
Street Name
Casco Point
Street Type
Road
Address
2618 Casco Point Road
Document Type
Land Use
PIN
2011723240038
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� REWARD. � <br /> WALL SY9TEM8 Build Different. Build Berter.SM <br /> How to Use the Lintel Reinforcement Tables <br /> Step 1 -Review the design criteria used to establish the lintel reinforcement tables to determine <br /> if they are applicable. In particular,verify that there are no concentrated loads applied to the <br /> lintel. <br /> Step 2-Determine the lintel height above the opening. Tables are provided for lintel <br /> heights of 8", 12", 16",24",and 32". Intermediate lintel heights may be reinforced according to <br /> the table for the next smaller lintel height. <br /> Step 3-Determine the lintel span that is the width of the cleaz opening under the lintel. <br /> For spans that are intermediate to the spans shown in the lintel tables,use the next largest lintel <br /> span. <br /> Step 4-Determine the factored load per foot of lintel. Use the expected dead and live <br /> applied loads or the code required minimum loads multiplied by the appropriate load factors. The <br /> factored loads given may be used for conditions that do not exceed those shown above for typical <br /> residential construction. <br /> Step 5—Find the appropriate table for the selected lintel height and the Reward iForm <br /> being used(9", 11"or 13").Find a load in the table equal to or greater than the applied factored <br /> load determined above. Read from the tabte the required bending(top&bottom)reinforcement <br /> (1-#5, l-#6,2-#5�and the required shear reinforcement(#3 stirrups or welded wire <br /> reinforcement). <br /> Issued on: 4/1/2003 6-Zg <br /> Release: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.