My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008-00070 - new septic
Orono
>
Property Files
>
Street Address
>
B
>
Big Island
>
710 Big Island - PID: 22-117-23-24-0009
>
Septic
>
2008-00070 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:11:32 PM
Creation date
2/22/2016 9:38:43 AM
Metadata
Fields
Template:
x Address Old
House Number
710
Street Name
Big Island
Address
710 Big Island
Document Type
Septic
PIN
2211723240009
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOSING CHAMBER SIZING with a Timer ' , <br /> 1. Determine area t Width <br /> A. Rectangle area=L x W � <br /> 0 ft x Oft = 0 ft� a � � <br /> Length <br /> B. Circle area=3.14 x radius2 <br /> 3.14 x 2(t = 0.0 ft� � <br /> C. Get area from manufacturer ft Radiu <br /> 2. Calculate gallons per inch <br /> There are 7.5 gallons per cubic foot of volume,therefore multiply the area(1A,B or C) <br /> times the conversion factor and divide by 12 inches per foot to calculate gallon per inch. � <br /> Surface area x 7.5/12= f� x 7.5 I 12inlft = 8.1 gallon per inch Leg21 Tank: <br /> 500 gallons or <br /> 3. Calculate recommended capacity=average design flow(see chart A-1) x 2 100%the daily flow ' <br /> 300 gpd x 2 = 600 gal or Alternating Pumps <br /> 4. Calculate total tank volume <br /> A. Depth from bottom of inlet pipe to tank bottom = 64 in A-1 Estimated Sewage Flows in GPD � <br /> B. Total tank volume=depth from bottom of inlet pipe to tank bottom(4A)x gallin(2) Number of <br /> = 64 in x 8.1 gallin = 518.4 gallons Bedrooms Class I Class II Class III Class IV <br /> 00 <br /> 5. Calculate gallons to cover pump(with 2-3 inches of water covering pump) 3 450 300 218 the � <br /> (Pump and block hei ht+2 inches)x gallon per inch(2) 4 600 375 256 values <br /> ( 16 + 2 in) x 8.1 gal/in = 145.8 gallons 5 750 450 294 in the <br /> ti yuu 5zo 3s� uass i, <br /> 6. Calculate total usable tank volume 7 1050 600 370 II or II � <br /> total tank volume in gallons(4)-gallons to cover pump(5) 8 1200 675 408 columns <br /> 518.4 gal - 145.8 gal = 372.6 gal <br /> 7. Calculate total pumpout volume � <br /> A. Select pump size for 4-5 doses per day. Gallon per dose=gpd(see Figure A-1)l doses per day= <br /> 300 gpd / 12 doseslday = 25 gallons <br /> B. Calculate drainback E•20 Volume of Li uid in Pi e <br /> 1. Determine total pipe length 120.0 ft Pipe Diameter Liquid per foot , <br /> 2. Determine liquid volume of pipe, 0.17 gal/ft(see figure E-20) inches ailons <br /> 3. Drainback quantity= 120 ft(7B1) x 0.17 gal/ft(762) 20.4 gallons 1 0.045 <br /> C. Total pump out volume=dose volume(7A)+drainback(763) 1.25 0.078 <br /> 25 gallons+ 20.4 gallons= 45.4 gallons 1.5 0.11 ' <br /> 2 0.17 <br /> 8. Pump Rate 2.5 0.25 <br /> From design 20 gpm 3 0.38 <br /> or calculated: 4 0.66 � <br /> chan�th(in)x gallon per inch(2)/time interval in�pm <br /> 4 in x 8.1 gallin / 60 min = 0.5 gpm � <br /> 9. Calculate the timer ON setting r�:�, `=`-R------==--� <br /> Dose gallons(7C)/gpm(8) ' ��< <[�� � �,+ � � <br /> 45.4 gal ! 20.0 gpm = 2.3 minutes ON � -- _ > • <br /> i"rr,r.,,. v ma� <br /> �ur�i. <br /> 10. Calculate the timer OFF setting ,!�,rr��",�� r -.� , � <br /> minutes per day/doses per day-minutes on �<< `.is�,,�,:��'���'<<i„�,j.�.; :� <br /> 1440 / 12 doses/day-min on(9) 117.7 minutes OFF <br /> � <br /> ' <br /> 1 <br /> � <br /> Page 1 of 1 <br /> ' <br />