Laserfiche WebLink
�� � .� . .. <br /> � �T/�� � door header �y,AR'���e �'� �'`� `` <br /> �� ` (�U� � �..� � <br /> ""'w�`',:'r"Sr`"°'`°"' 2 pcs of 1 3/4" x 11 7/8" 1.9E Microllam0 LVL <br /> TJ-BeamO 6.16 Serial Number:7003023075 <br /> User:1 2!7/2005 11:18:34 AM <br /> Page1 EngineVersion:1.16.5 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN <br /> CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> Member Slope:OM2 Roof Slope0M2 <br /> 7❑ 2❑ <br /> b s.7��� <br /> All dimensions are horizorrtal. Product DiaAram is Conceptual. <br /> LOADS: <br /> Analysis is for a Drop Beam Member. Tributary Load Width:8' <br /> Primary Load Group-Snow(psf):35.0 Live at 115%duration, 17.0 Dead <br /> Vertical Loads: <br /> Type Class Live Dead Location Application Comment <br /> Point(Ibs) Snow(1.15) 3040 1520 2' - <br /> SUPPORTS: <br /> Input Bearing Vertical Reactions(Ibs) Detail Other <br /> Width Length LivelDeadlUpliftlTotal <br /> 1 Trimmers 3.00" 1.76" 3062/1555/0/4617 L2 None <br /> 2 Trimmers 3.00" 1.50" 1822/935/0/2757 L2 None <br /> -See TJ SPECIFIER'S/BUILDERS GUIDE for detail(s): L2 <br /> DESIGN CONTROLS: <br /> Maximum Design Control Control Location <br /> Shear(Ibs) 4564 4087 9081 Passed(45%) Lt.end Span 1 under Snow loading <br /> Moment(Ft-Lbs) 7805 7805 20525 Passed(38%) MID Span 1 under Snow loading <br /> Live Load Defl(in) 0.048 0.211 Passed(U999+) MID Span 1 under Snow loading <br /> Total Load Defl (in) 0.072 0.317 Passed(U999+) MID Span 1 under Snow loading <br /> -Deflection Criteria:STANDARD(LL:U360,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 6'7"o/c unless detailed otherwise. Proper attachment and positioning of <br /> lateral bracing is required to achieve member stability. <br /> -Design assumes adequate continuous lateral support of the compression edge. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this software will <br /> be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application, input design loads, <br /> and stated dimensions have been provided by the software user. This output has not been reviewed by a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Building Code UBC analyzing the TJ Distribution product listed above. <br /> -Note:See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION: OPERATOR INFORMATION: <br /> chalfen Rich Garetz <br /> Justus Lumber <br /> 330 Eleventh Ave.S <br /> Hopkins, MN 55343 <br /> Phone:952-938-2741 <br /> Fax :952-938-0930 <br /> rgaretz@schererbros.com <br /> Copyright ° 2004 by Trus Joist, a weyerhaeuser Business <br /> Microllam° is a registered trademark of Trus Joist. <br />