My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic info
Orono
>
Property Files
>
Street Address
>
B
>
Brown Road South
>
445 Brown Road South - PID: 03-117-23-31-0001
>
Septic
>
Septic info
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:13 PM
Creation date
2/4/2016 12:09:40 PM
Metadata
Fields
Template:
x Address Old
House Number
445
Street Name
Brown
Street Type
Road
Street Direction
South
Address
445 Brown Rd S
Document Type
Septic
PIN
0311723310001
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_� <br /> %. �O \�. <br /> � � �,� <br /> � � �A, <br /> � � �� �� ��� CITY of ORONO <br /> ,,� �, i'�.'�.. � ' <br /> `� �,� ��,. � ti � � Municipal Offices <br /> � ,v+� � � `�`�`' G~/ Street Address: Mailing Address: <br /> � <br /> ���`9I�'ESKQ�'� � 2150 Kelley Parkway P.O. Box 66 <br /> =___ � Orono, MN 55356 Crystal Bay, MN 55323-0066 <br /> G <br /> Owner: �,�I C: � r�� � � � \ Address: 445 Brown Rd. S. <br /> Permit #'s: none Dates: Contractors: unknown <br /> (This is [ �'] an existing system [ ] new construction) . <br /> SYSTEM COMPLIANCE (1-3) : 3 <br /> 1 Code System: Meets or exceeds curren� City standards in all respects relating to design, <br /> construction, and location. Appears to be operating properly. <br /> 2 Compliant System: Does not meet all current City standards for new construction, but in <br /> most respects appears to be designed, iocated, and constructed in accordance with previous <br /> codes and is functioning properly. <br /> ��� Non-Compliant System: System may or may not meet current City standards for design, <br /> construction, or location, but is failing to properly treat and dispose of the current <br /> input; and any system with less than tn�ee feet of vertical separation between the bottom of <br /> the drainfield and the saturated soil level. <br /> (The saturated soil level is [�] or is not [ ] identified under this septic system. If the <br /> saturated soil level is not identified, this classification is subject to revision.) <br /> TANK CONDITION (5-9) : 8 <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year. <br /> 7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br /> /� Inspection risers missing-tanks could not be inspected. If tanks have not been pumped out <br /> ��- within three years, they should be pumped out and risers installed now. <br /> 9 Inspection pipe is located over tank baffle-can not measure solids accumulation. If tanks <br /> have not been pumped out within three �ears, they should be pumped out now. <br /> 10 One or more tanks are cesspools, which means the septic system is non-compliant. <br /> (The tanks are ( ] or are not [ ] water tight or the condition is [�] unknown. If the tanks <br /> are not confirmed to be watertight, this classification is subject to revision.) <br /> DRAINFIELD CONDITION (11-14) : 14 <br /> 11 Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not criticai yet. Repair is not required at this time. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br /> the City Inspector immediately. Repair must be completed within 90 days. <br /> �`19�; Drainfield extent and condition unknown. <br /> POTENTIAL FOR SYSTEM FAILURE: (system age ar.d condition, soils, etc. ) : medium <br /> COMMENTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br /> were performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br /> The separation is 0 feet and the system is non-compliant. Repair or replacement of the septic <br /> system is required by 12/31/2002. <br /> � v <br /> �t�.-' � � �� � L�1 � � � fL,--- <br /> � Date of Inspection S ptic System Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a <br /> transfer of property, this report does not guarantee that an existing system will continue to <br /> function properly, but indicates the operation of the system under current conditions. <br /> Telephone (612) 473-7357 • FAX 473-0510 <br />
The URL can be used to link to this page
Your browser does not support the video tag.