Laserfiche WebLink
� <br /> Job Name: ZB COMPANIES/WILLIAMS Truss ID: C1 JID:385179 <br /> BRG X-LOC REACT SIZE REQ'D TC 2x4 SPF #1;-2-CAN Web bracing required at each location shown. UPLIFT REACTIOti(S) : <br /> 1 0- 2-12 2222 5.50" 3.48" 2x4 SPF Q100F1.SE o-9 � See standard details (TX01087001-001 revl). Support Main Wind Non-Wind <br /> 2 37- 4- 4 2200 5 SO" 2.88" 2x4 SPF C1o50F1.5E 9-11 Designed per ANSI/TPI 1-2002 1 -144 lb <br /> BRG REQUIREMENTS sho�zn are based ON�Y gC 2x4 SPF #1/#2-CAN Plating is based on quality control factors 2 -157 16 <br /> on the truss material at each bearing 2x4 SPF Q 100F1.8E 18-20 Cq = L 25 for wide face and This truss is designed using the <br /> MAX DEFLEC7ION (span) : WEB 2x3 SPF STUD-CAN Cq = L 25 for narrow face. ASCE7-0S Wind Specification <br /> L%�99 MEM 17-18 (LNE) LC 21 2x3 SPF #1/�2-CAN 1-14, 4-1"o Any alterations to this are shown for Bldg Enclosed = Yes, Importance F-actor = 1.00 <br /> L= -0.38" D= -0.42" T= -0.81" l0-8. 15-1° individual joints on the ]oint Report. Truss Location = Not End Zone <br /> carncn�wenteea waces: � g-19 This design does not account for long term Hurricanei0cean Line = No Exp Caiegory - E <br /> TC COMP.(DUR.)/ 7EN5.(�UF.) CSI Zza SPF =1,'=2-CAN 1V'-2t� time dC endent loadin cree <br /> i-z -2ez7U.15>/ 14s(1.eo) o.sa � p �g ( p). Bu�lding Bldg Lengih = 49.99 ft, Bldg Width = SO.Gu }: <br /> Z-3 -i55t(t.1s)/ iee(i.eo) o.so Lumber shear allo�r;ables are per NDS. Designer must account for this. Mean roof height = l0".34 ft, mph - 90 <br /> 3-a -zsoa(1.15)/ 1ea(1.eo) o.ez THZS DESIGN IS THE COMPOSITE RESULT OF Refer to Joint QC Detail Sheets for ASCE7 II Standard Occupancy, Dead Load = L:i.2 psf <br /> n-5 -2oao(1.15)/ uip..6o) 0.91 MULTIPLE LOAD CASES. Cq factors and Rotational Tolerances. Desiqned as Main Wind Force Resistin Syseem <br /> s-5 -i3sU.is�/ se(l.zs) o.zs IF THIS TRUSS IS CARRIED IN A HANGER, THAT IRC IBC tr�ss late values are based on - Low-rise and Com onents and Cladd�n <br /> 6-7 -233(1.15)/ 20(1.b0) 0.85 � P P 9 <br /> 7-a -ineU.is)/ ziSU.eo) o.se HANGER IS BASED ON 1S" HANGER NAILS FOR testing and approval as required by IBC 1703 Tributary Area = 75 sqft <br /> a-s -zoss<t.is); iasU.eo) o.e3 1-PLY AND 3" HANGER NAILS FOR MULTI-PLY and ANSI/TPI and are reported in available <br /> 5-io -na5U.i5)/ t7z(t.Go) 0.78 CARRYING MEMBERS. IF 2.5" GUN NAILS ARE document ESR-ll18. <br /> io-u -toG(i.ts)! tso(t.i5) o.n USED, THE NANGERS MUST BE RE-EVALUATED Loaded for 10 PSF non-concurrent BCLL P.EPAI�.: QO?70'�1 t_HCRD YKU��I�E i'�;!,:ST �=''�.�5�'�" <br /> ec cowP.(ou2.>/ ieNs.(ouk.) csi (BY OTHERS). End verticals are designed for axial loads �n�!�la�T I` �:10'.�iN 0"J 7"!"�:�$ji-u, 'R.i!5�; '... . <br /> tz-tl -5(i.5o)/ a9(t.15) o.ii only unless noted otherwise. <br /> 13-1a / eaU.zs) 0.11 Extensions above or below the truss profile �� ;\DF <br /> ia-is -iz3<i.so>/ zi�o<i.is) o.�i QUATELY �UFFGRT THt TRU�S <br /> is-ie -3o(i.5o)/ zosz(i.is) o.5s (if any) have been designed for loads U1TIl. THF REPAIR IS COP�IFLETE. <br /> te-i7 / i6o(i.zs) o.1a indicated only. Hori mntal loads applied at �� BUILD lHE SPLI(E FRA�^•'E(S? <br /> v-ia -1(i.ao)/ soU.ts) o.es the end of the extensions have not been � <br /> is-i� i(i.eo)/ so(i.is> o.�z US1NG 7I1E LUti'BER A'vD Plti'I"Ec <br /> i�-io ao(1.50)/ 1728Q.15) OJ9 considered unless snown. A drop-leg to an <br /> otherwise unsupported wall may create a AS SH04.'N 0� TRUSS 'C JID 3fi'ii%9. <br /> ws COMP.(DUR.)/ reNs.(ouu.) csi hinge effect that requires additional design ATTACN TNF FRAME(5) TO GNE <br /> ta-z -sz3(i.is)/ seU.eo) o.tz consideration (by others). F.4CE �JITH lOd 'dAILS AS �HO'.ti'"d <br /> 16-5 -al(1.60)/ 880(1.15) 0.36 <br /> i-iz -zi�a(i.is)� ise(i.eo> o.e9 PEft FRALE. <br /> i-ia 9�<i.w>/ zies(i.is> o.�s IF NOT SPLCIFIEL', US[ lOd AT <br /> iz-ia -szo<i.ao>/ soz��.ao> o.ia 6" O.C. IN ALL OTHER hiB•iBERS <br /> o-is -laaci.ls)� 3aai.z�> o.i9 FRAME TRUSS AREA THAT OVERLAP '.vITH THE FRAME. <br /> a-is -n3(i.is>j imci.so> o.ez DISTRIBllTF THE NAILS EVFNLS' <br /> 5-7 -1531(1.15)/ 234(1.60) 0.91 <br /> e-16 -206(1.60)/ is3�i.so> o.z9 THft0UGH0UT THE CI'�ENSIOti <br /> iea9 / iseau.is) o.sa SPKIFIED On ALONG THE M,'FE3 <br /> 8-19 / 383(1.25) 0.12 . <br /> io-i9 -izs(i.is)/ vo(i.ao) o.zo 19-0-0 18-7-0 OR FatiEL LENGTHS. <br /> io-zo -zui(i.is>/ 98(1.60) o.ai � z 34 5 6 7 8 9 10 11 <br /> ii-zo -suU.is)/ iesU.eo> o.ie .: qpP'.-' p,tiY �.^D?T;n\AL i.P.TEi?Ai. F.RACI":G <br /> 8.� _p �.. = SPLI T,tL_ Slli?tt'v. <br /> R3X5 <br /> 4X6 3X4 <br /> 3X5 <br /> 26-10d <br /> 3X4 S=3X8 <br /> S=3X8 <br /> 14-6-0 5X10 14-6-0 <br /> SHIP <br /> 3X4 6-10d <br /> / .� <br /> 6X6 2X3 <br /> r T <br /> 1-10-0 5X0 3X4 5X8 �i-5 7i9i.d,'��P;Zt�}:tfi�]I�Y� �6'ti;l�7 i-1i1�Pi..�'+.�i`7�.. <br /> 4X63X4 1-0-0 3X4 S=3X6 4X10 4X6 t.-ik�i+ 1!tta�.t)It I:Ct��1:s` ��t5 i'P2i f'-a)d1��i) <br /> 135�1�4t.C71S 1,�1It.7t d17 Ra€KE.i-7 hL.i'Eitl IiiSt\ <br /> B1 2o-1od 82 &'�t?Tti 1 t I i�l >1)1�t 2 iti'.t:15t 1'.xt.!?Pi.t7- <br /> W:508 W:508 F�I�;^+^(t3\t#�h�t.l�{k:lt t�3�E:t'd t ttk.1_.4�.5 t <br /> R:2222 3-5-8 21-0-8 R2266 t�l' �Nt �i �kF uI Sti� �+�P� <br /> U:-144�q 13-1-0 ��:-157 i � f <br /> 37-7-0 <br /> _........ .....__.........�._. .. ..........___n.�_..__.�._..,.. <br /> �12 1B4 15 167 18 19 20 f�.!'_ai TI?R <br /> All connector plates are Truswal 20 ga.or Wave 20 ga.,unless preceded by"HS"for HS 20 ga.,"S"for SS'I B ga.from Alpine; ��'+�3 i.t�;t�i�K l ilt}��i5.v3�€ar <br /> or preceded by"MX"for TWMX 20 ga.or"H"for 16 ga.from Truswal,positioned per Joint Detail Reports. Circled plates and false 9/2 5/2008 <br /> frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates(or staple). <br /> FOR: 143-Villaume Ind.Inc. WARNIN Read all notes on this sheet and give a copy of it to the Erecting Contractor. c�5c: �aMPERT vaR�s - n.v. <br /> 2926 Lone Oak Circle This design is for an individual building component nottruss system It has been basetl on specifications D�ovbed by the component manu�actuier W0: D ri ve_P_60202 5_L00005_J 00001 <br /> �.Paul.MN 55121 antl done in acwrdance with the current versions of TPI and AFPA tlesign standartls Nu resDonsibiliry is assumetl for tlimensional accuracy Dimensions <br /> are to be verified by the component manufacturer and/or building designer pnor to fabrication.The building Aesigner must asceAain that the loads Dsgn r: S J S #�� = 2 Z IM1�T�: Z 5$# <br /> e y:T R U S WA L utilized on this tlesign meet or exceed the loatling imposed by the local building co0e and the particular appiication The design assumes that the top chortl T� Li ve( ) 3 5.00 PSf L i veDu r �=1.1$ P=1.15 <br /> �is laterally braced by the roof or Floor s�eathing and the bottom chord is taterally braced by a rigid sheathing material directly atlached.unless otherwise TC S now Pf Q.�� Sf SnowDu r �=1.1$ P=1.15 <br /> noted.Bracing shown is for lateral support of components members onty to reduce buckling length.This component shall not be placed in any <br /> � SYSTEMS environmentmatwilicausememoisturecontentotthewoodmexceedl9/andbrcauseconnectorplatewrwsion Fabricate,handle,install T� Dedd 7.00 psf Rep Mbr Bnd / Comp / TenS <br /> and biace this imss in acwrtlance with the followirg standards:'Joint a(M Cutting Detail Repons'available as output tiom Tmswal so(tware. BC Li ve �.�� p5f 1.15 / 1.1� � 1.l� <br /> /��BuildinJ COmpon0nt5 Group,I�t. 'ANSIlTPI i'.'WTCA 1'-Wood Truss Council of America Stantlard Desgn Responsibilities.'BUILDING COMPONENT SAFETY INFORMATION'- BC DedCJ 10.00 psf 0.C.Spaci ng Z- �- � <br /> 4445 Northpark Dr.Sfe.702,Colo.Spgs.,CO 80907 �gCSI 1-03)and'BCSI SUMMARY SHEETS'by�NTCA and TPI.The Truss Plate Institufe(TPI)is located at 583 D'Onohio Diive,Madison. <br /> TRUSPLUS 6.0 VER: T6.5.7 wlsconsin597i9 TneameacanFoiestandPaperAssocianon�aFPFllsbcatetla:�i�ii9tnStreet.N�^✓.SteBooWasningtoaDC2oo36 Bldg Code: IRC-2006 DEFL RATIO: L/240 TC: L/180 <br />