Laserfiche WebLink
' ` - - -- - ___ - _ _ . <br /> RHVAC-Residential HVAC Load Calculations Elite Software Development,lnc. <br /> Flare Heating &,�/C Inc. .�' Rambler Tov✓nhome Duplex(Cascade) <br /> Golden�Valley MN 55427-3700 ; <br /> - --- ___ - _ _ Page 2 <br /> _ - - <br /> - __- _ __ <br /> - __ _ _ <br /> �'� �,i�r�� � (lr���a�ed) Summary Loads <br /> i:omponent _ _ -_ � - - <br /> Description �rea Sen Lat Sen Total <br /> - --- Quan Loss Gain vain ' Gain <br /> 4A Window Double Pane & Storm Clear Glass Wood Frame 380 11,922 0 10,156 10,156 <br /> 8M Glass Door pouble Clear Giass Wood Frame 40 2,028 0 1,520 1,520 <br /> 11C Door Metal Polystyrene Core 40 1,730 0 363 363 <br /> 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 1370 6,934 p �,7�g � ��8 <br /> 131 Part R-19 + 1/2" Asphlt Board(R-1.3) 178 901 0 147 147 <br /> 15C Wall 2-5' Below Grade 8/12" BIk+R-11 315 1,478 p p � <br /> 15G Wall 5' or More Below Grade 8/12" BIk+R-11 74g 2 g59 � � Q <br /> 161 Ceiling R-44 Insulation 1954 4,135 0 1,977 1,977 <br /> 20J Floor Over Open Crawl Carpet + R-30 g 29 � 5 5 <br /> 21A Basemt Fioor 2' or More Below Grade 1940 4,284 p 0 � <br /> _ __ _ _ __ <br /> - _- <br /> Subtotals for structure: - ---- <br /> 36,400 0 15,946 15,946 <br /> People: 8 1,840 2,400 4,240 <br /> Equipment: 300 1,200 1,500 <br /> Lighting: � O O <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 253, Summer CFM: 127 24,845 3,004 2,700 5,704 <br /> Ventilation: Winter CFM: 125, Summer CFM: 125 12,273 2,968 2,668 5,636 <br /> ._ - <br /> _ <br /> Sensible Gain Total: -- <br /> Temperature Swing Multiplier: 24,914 <br /> - - _ _ - _ X1.00 <br /> - __ __ __ <br /> System 1 (Imported) Load Totals: -- <br /> 73,518 8,112 24,914 33,026 <br /> __ _ <br /> ___ - <br /> Checl; Figures _ - - <br /> �._. <br /> _ -- - <br /> Supply CFM: _ 1,042 - __ CFM Per Square ft.: _ 0.268 _ <br /> Square ft. of Room Area: 3,894 Square ft. Per Ton: 1,414.871 <br /> _-- - --- <br /> - <br /> System Lc?ads . _ -- <br /> _ - _ _. <br /> Total Heating Required With Outside Air: 73,518 Btuh 73.518 MBH <br /> Total Sensible Gain: 24,914 Btuh 75 % <br /> Total Latent Gain: 8,112 Btuh 25 % <br /> Totai Cooling Required With Outside Air: 33,026 Btuh 2.752 Tons (Based On Sensible + Latent) <br /> __ 2.768 Tons (Based On 75% Sensible Capacity) <br /> _._ __. <br /> t�lotes __ _ ___ -- -- <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> Ali computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> __ _ _- -- <br /> S:\FHDATA\PROJECTS\Z&B\stonebay rambler cascade.rhv Monday, April 24, 2006, 11:50 AM <br />