<br /> RHVAC-Residential HVAC Load Calculations Elite Software Development,lnc.
<br /> Flare Heating &,�/C Inc. .�' Rambler Tov✓nhome Duplex(Cascade)
<br /> Golden�Valley MN 55427-3700 ;
<br /> - --- ___ - _ _ Page 2
<br /> _ - -
<br /> - __- _ __
<br /> - __ _ _
<br /> �'� �,i�r�� � (lr���a�ed) Summary Loads
<br /> i:omponent _ _ -_ � - -
<br /> Description �rea Sen Lat Sen Total
<br /> - --- Quan Loss Gain vain ' Gain
<br /> 4A Window Double Pane & Storm Clear Glass Wood Frame 380 11,922 0 10,156 10,156
<br /> 8M Glass Door pouble Clear Giass Wood Frame 40 2,028 0 1,520 1,520
<br /> 11C Door Metal Polystyrene Core 40 1,730 0 363 363
<br /> 121 Wall R-19 + 1/2"Asphlt Board(R-1.3) 1370 6,934 p �,7�g � ��8
<br /> 131 Part R-19 + 1/2" Asphlt Board(R-1.3) 178 901 0 147 147
<br /> 15C Wall 2-5' Below Grade 8/12" BIk+R-11 315 1,478 p p �
<br /> 15G Wall 5' or More Below Grade 8/12" BIk+R-11 74g 2 g59 � � Q
<br /> 161 Ceiling R-44 Insulation 1954 4,135 0 1,977 1,977
<br /> 20J Floor Over Open Crawl Carpet + R-30 g 29 � 5 5
<br /> 21A Basemt Fioor 2' or More Below Grade 1940 4,284 p 0 �
<br /> _ __ _ _ __
<br /> - _-
<br /> Subtotals for structure: - ----
<br /> 36,400 0 15,946 15,946
<br /> People: 8 1,840 2,400 4,240
<br /> Equipment: 300 1,200 1,500
<br /> Lighting: � O O
<br /> Ductwork: 0 0 0 0
<br /> Infiltration: Winter CFM: 253, Summer CFM: 127 24,845 3,004 2,700 5,704
<br /> Ventilation: Winter CFM: 125, Summer CFM: 125 12,273 2,968 2,668 5,636
<br /> ._ -
<br /> _
<br /> Sensible Gain Total: --
<br /> Temperature Swing Multiplier: 24,914
<br /> - - _ _ - _ X1.00
<br /> - __ __ __
<br /> System 1 (Imported) Load Totals: --
<br /> 73,518 8,112 24,914 33,026
<br /> __ _
<br /> ___ -
<br /> Checl; Figures _ - -
<br /> �._.
<br /> _ -- -
<br /> Supply CFM: _ 1,042 - __ CFM Per Square ft.: _ 0.268 _
<br /> Square ft. of Room Area: 3,894 Square ft. Per Ton: 1,414.871
<br /> _-- - ---
<br /> -
<br /> System Lc?ads . _ --
<br /> _ - _ _.
<br /> Total Heating Required With Outside Air: 73,518 Btuh 73.518 MBH
<br /> Total Sensible Gain: 24,914 Btuh 75 %
<br /> Total Latent Gain: 8,112 Btuh 25 %
<br /> Totai Cooling Required With Outside Air: 33,026 Btuh 2.752 Tons (Based On Sensible + Latent)
<br /> __ 2.768 Tons (Based On 75% Sensible Capacity)
<br /> _._ __.
<br /> t�lotes __ _ ___ -- --
<br /> Calculations are based on 7th edition of ACCA Manual J.
<br /> Ali computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads.
<br /> __ _ _- --
<br /> S:\FHDATA\PROJECTS\Z&B\stonebay rambler cascade.rhv Monday, April 24, 2006, 11:50 AM