Laserfiche WebLink
�• r <br /> 15-3739 <br /> May 18,2015 <br /> Page 7 of 8 <br /> Lot 1, Block 3: The lot is shown to have 3.01 total acres and 2.85 dry, buildable acres in area. It <br /> is proposed to have approximately 22Q feet of frontage on Hunter Drive where it will gain <br /> access. It appeazs that all building setbacks could be met for a principal structure on this <br /> lot. Much of this lot is covered with established prairie vegetation; there is a wetland on <br /> the eastern lot line. <br /> Applicant's Conservation Design Report Comments: Prairie grass preservation area <br /> over the ftrst 1 SO'ftom the western boundary going east except for septic usage. 30' <br /> preservation from the eastern boundary for prairie al�o. Buffer trees are also to be <br /> planted by developer. Lot is accessed from Hunter Drive. <br /> Lot 2, Block 3: Like Lot 1, Block 3, this lot will front and gain access via tiunter Drive. It is <br /> shown to have approximately 270 feet in width and has 2.95 total acres of which 2.61 are <br /> dry. It also is curxently primarily established prairie vegetation and has a wetland along the <br /> reaz {east) lot line and along the south lot line. It appears that building setbacks can be met <br /> for a principal structure on this property. <br /> Applicant's Conservation Design Report Comments: Prarie grass preservation over the <br /> ftrst I SO'from the western boundary going east except for septic purposes.Also a 40' <br /> southern boundary and a 30'easterly boundary shall be in place to further preserve <br /> the prarie. The developer is to plant trees to protect and preser�ve the valuable view <br /> corridor that's been enjoyed for S0+years.Access is from Hunter Drive. <br /> Road Layoat and Standards <br /> There are two proposed private road corridors (Outlot E and Uutlot F) serving the proposed <br /> subdivision. Both are shown to be 50 £eet in width. Both proposed roads are shown with a 100' <br /> diameter cul-de-sac as required by the Subdivision Ordinance and the CMP for a local private <br /> road. The standard paved width for the road in Outlots E and F would be 24 feet with an 80 foot <br /> diameter paved cul-de-sac. Proposed Outlot F appears to requitre significant filling & grading and <br /> has potential i.mpact on the septic sites for Lot 5. Total Iength of road a,n Outlot F is about 1550', <br /> exceeding the code standard maacimum length of 1000'. The driveway to serve Lot 2 Block 2 <br /> adds an additional 600 feet. While applicant has suggested that use of the existing roadbed is <br /> desired, the minimum width for the entire road should be no less than 24 feet, as noted in the <br /> City Engineer's comments. <br /> The 30' access corridor shown for Lot 2 Black 1 would function as the access to the back lot. For <br /> Lot 2 Block 2 the access corridor has been widened to allow for flexibility in driveway <br /> placement to avoid tree removal. <br /> Road Improvements and/or Easements Needed <br /> The Ci.ty will require a Road, Drainage and Utilities Easernent over the private roads. Standard <br /> perimeter d�rainage and utility easements will be required along all property boundaries in the <br /> plat as well as Canservation and Flowage Easements over any delineated wetlands and <br /> draanageways. <br />