My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Project Packet
Orono
>
Property Files
>
Street Address
>
B
>
Bohns Point Road
>
1540 Bohns Point Road - 09-117-23-33-0007
>
Land Use
>
98-2348, VAR
>
Project Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2026 11:40:38 AM
Creation date
2/26/2026 11:38:47 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rick Hauser <br />March 16, 1998 <br />Page2 <br />Existing Conditions <br />For the drainage analysis, MFRA visited the site, took photographs and reviewed information <br />from your surveyor and landscape architect. The existing site generally drains south towards the <br />southerly lot line and east to Lake Minnetonka. There is a low area approximately 75 feet upland <br />of the lake near the southerly property line that may hold water on the adjacent lot during rainfall <br />events. The low area receives runoff from the Hauser lot and the lot to the south. Runoff from <br />portions ofBohn's Point Road also reaches the low area as evidenced by minor erosion along the <br />east side of the roadway leading into the Hauser lot. <br />Calculations and Schematics <br />The drainage calculations and proposed depression schematics prepared with this analysis were <br />based on providing a small low area to retain the excess runoff from hard cover exceeding the <br />allowable amount. The proposed depression is shown on the attached figure. The depression will <br />retain runoff from most storm events and will be drained by infiltration into the ground. The <br />Hennepin County Soils Survey shows the surface soils being Hayden loam which have moderate <br />infiltration rates. In larger storm events, or if the depression is at capacity, it would overflow east <br />towards the lake. Since there are no standard requirements for sizing a depression in the case of a <br />variance request, MFRA reviewed runoff volumes from various storm events for the excess hard <br />cover and prepared a schematic that fits the existing lot and proposed building configuration. The <br />calculations assumed that the depression would be dry prior to rainfall events and be available to <br />receive and store runoff. Retention volumes for the excess hard cover for various storm events <br />are shown on the following table: <br />Storm Event <br />10 year-24 hour <br />50 year-24 hour <br />100 year-24 hour <br />Precipitation (in) <br />4.2 <br />5.3 <br />6.0 <br />Excess Runoff Volume (c.f.)* <br />542 <br />684 <br />775 <br />*Excess runoff volume equals 1,549 s.f. multiplied by precipitation in feet <br />The attached figure shows the proposed depression having a volume of717 c.f. (26.6 c.y.) <br />between elevations 931 and 933. That volume would retain runoff for storm events in excess of <br />the 50 year event. The depression would be created by excavating a basin to a depth of <br />approximately 3 feet and the construction of a small berm to retain runoff. Another location for <br />the depression, and perhaps simpler and less intrusive for the property, would be near the south <br />east corner of the lot in an area more distant from the proposed house and lower in elevation. <br />However that location was not further pursued since we understand that water storage areas are <br />not allowed within 75 feet of the lake by city code.
The URL can be used to link to this page
Your browser does not support the video tag.