My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
01-12-1987 Council Packet
Orono
>
City Council
>
1987
>
01-12-1987 Council Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2026 10:23:39 AM
Creation date
2/2/2026 10:14:02 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
To: 'zoning File #1093 <br />From: Mic.ha,:? P. Gaf f ron, <br />Asst Planning & Zoning Ail -in- .rator <br />Date: November .3, 1986 <br />Subject: Septic Systems Review <br />Proposed Lot 1 <br />A. Existing System (existing house) was last inspected in August <br />1986; system appeared to be substandard in size but functional; <br />the house may not. have been occupied at the time. <br />B. Alternate Site tested in area south of house - average <br />perculation 107 MPI, average slope 6-8%, mottling at 18", 27", <br />30" - site would be suitable for a mound system. <br />Proposed Lot 2 <br />A. Primary Site tested on southwest -facing slope - average <br />perculation 47.4 MPI, average slope 9-18%, rottling 36", 44", 40" <br />site is marginally suitable for a mound, is adjacent to <br />drainage swale - needs additional review <br />B. Alternate Site tested on south -facing slope - average <br />perculat::on 49.3 MPI, average slope 12-20%, mottling at 48", 40", <br />30" - site is very questionable for a mound given the slopes and <br />proximity to drainageway. <br />Proposed Lot 3 <br />A. Primary Site tested on southwest -facing slope - average <br />perculation 38.9 MPI, a erage slope 10-12%, mottling at 48", 48" <br />- site is suitable for a st•.allow trench system, needs curtain <br />drain. <br />B. Alternate Site tested just downhill from primary - average <br />perculation 49 MPI, average slope 3-4%, mottling at 30", 29" - <br />thin :_t_e is suitable fo,, a mound system. <br />Proposed Lot 4 <br />A. imary Site tested on northeast facing slope near "s e" <br />of lot - unclear between topography and site evaluators no., as <br />to exact location - average perculation 38.3 MPI, average slope <br />15 -20% apparently, mottling at 48", 47" - site is suitable for <br />shallow trench system if cur' is installed and if site is <br />actually on the slope and not in the saddle area. <br />B. Alternate Site tested northwest. of primary site - average <br />perculation 46.9 MPI, average slope 7-10%, mottling at 41", 42" - <br />sito is suitable for a mound oystem. <br />
The URL can be used to link to this page
Your browser does not support the video tag.