My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1996-06-19 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
503 Ferndale Road North - 36-118-23-13-0005
>
Septic
>
1996-06-19 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2026 3:38:36 PM
Creation date
1/21/2026 3:28:17 PM
Metadata
Fields
Template:
x Address Old
House Number
503
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
503 Ferndale Road North
PIN
3611823130005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S•P TESTING, INC. Steven B. Schirmers - MPCA Cert.No. 627 <br />951 Katydid Lane NE - St. Michael, MN 55376 - (612) 497-3566 <br />FAX (612) 497-5011 <br />State License #394 <br />June 19, 1996 <br />Dale Spencer <br />503 Ferndale Rd. <br />Orono, Henn. Co., MN <br />This site has an existing failing On -Site Sewage Treatment System which does not meet <br />the 3' separation from the saturated soil (mottled soil). The system is surface <br />discharging which is an imminent health hazard & must be repaired or disconnected <br />within 10 months. <br />This On -Site Sewage Treatment System is Designed for a Type 1, four bedroom home, <br />Designed in accordance with the Minnesota Poilution Control Agency Chapter 7080 and <br />local ordinances. <br />The soils on this site are SCS soils mapped - HbC - Hayden loam. The seasonally <br />saturated soils were located at 54" to 70" (mottled soil). The bottom of the treatment <br />area must be located at least 3' above the seasonally saturated soils. A Standard <br />shallow Trench System 18" deep, may be installed using gravelless trench. <br />The soils at a depth of 18" have a percolation rate averaging 7.2 mpi. <br />A pumping chamber will need to be installed to lift the septic effluent to the treatment <br />area. The power supply and switches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device must be installed with <br />a light and sound device, this is in case of a pump failure. <br />All neighboring wells are located greater than 100' away from the proposed treatment <br />area. <br />