Tip$ Jeanne A. Mabusth, Building & Zoning Administrator <br />FIVE$ Thomas J. Jacobs. Building & Fire Inspector <br />oat*: March 13, 1989 <br />Subject: #1385 Big Island Veterans' Camp - Cabins and Tents <br />Per your request, I have reE,riewed the Man for the Big Island <br />Veterans' Camp and have • .e following comments: <br />1. The cabin and tent locations appear t., be 50' apart as drawn on <br />the plans. Pursuant to NFPA requirements, Standard #22 1, Building <br />locations shall be located at least 40' apart. <br />Z. Pursuant to NFPA, Standard i224, a space of 100' or more must be <br />cleared of hazard vegetive growth around the strut .urea. 1,, ct 9 peui , WAAS— <br />3. Tent requirements. Pursuant to NFPA, Standard 1224, tents and <br />repairs made thereto shall meet the requirements of federal <br />specifications for flame resistive tsxtiles and requirements of NFPA <br />#701, Standard methods of fire test for flame resistant textiles and <br />files. <br />4. Pursuant to NFPA requirements, tents used for place of assembly <br />shall comply with the applicable requirements of NFPA 1102, standard <br />for essembly seating - tents and air supported structures. r1o*.A 4j;,�t,� <br />act Michael P. Gaffron, Asst Planning & Zoning Administrator <br />Lyle Oman, Field Inspector <br />