Laserfiche WebLink
#932 Edwards <br />Page 2 <br />June 24, 1985 <br />Now, looking only at the building site, note that we have to deal with <br />two 75' setbacks. The hardcover numbers presented by the applicant's <br />surveyor take into account only the lake setback, not the lagoon <br />setback. Hence, the total area of the building site within 0-75' of <br />shoreline is actually 18,750 square feet, with only about 11.250 <br />square feet in the 75-250' setback area. This mathematically raises <br />the 75-250' hardcover percentage but lowers the 0-75' percentage. <br />Technically, considering only the building site, 0-75' proposed <br />hardcover is 2,960 square feet or 15.8%, and in the 75-250' zone is <br />3,380 square feet or 30.0%. <br />The next point to consider, then, is which direction will the hardcover <br />drain to. It should be directed to the north, so that in the case the <br />variance is granted, drainage from the house and driveway will travel <br />over or through 100 feet of lawn area before reaching the lake. If all <br />runoff can be directed to the lagoon, the following hardcover numbers <br />would apply: <br />0-75' = 9,375 sf total area <br />75-190' = 14,375 s.f. total area <br />0-75' (lagoon) existing driveway = 1,400 sf (15%) <br />75-190' (190' is the proposed drainage break) <br />House <br />2,800 <br />+ <br />sf <br />Deck <br />360 <br />+ <br />sf <br />New Driveway <br />1,200 <br />+ <br />sf <br />Sidewalk <br />60 <br />+ <br />sf <br />Existing driveway <br />520 <br />+ <br />sf <br />Total <br />4,940 <br />sf <br />(34%) <br />0-50' (lakeshore) 0 hardcover = 0% <br />This method of calculating hardcover northodox but accomplishes <br />exactly what we are striving for in our ioff infiltration concerns, <br />i.e. it meets the intent but not the letter of the code. <br />Next, consider the average setback issue. Because the neighboring <br />owners have stated that they value the views of both their lake and <br />lagoon yards, they also request that the new house conform Pssentially <br />to the setback of the existing houses. Although the average "line of <br />sight setback" would be about 35' from the lakeshore due to the <br />curvature of the lake, the mathematical average setback is 49.5'. As <br />you can see from the survey, the applicants garage will encroach on site <br />lines toward the lagoon. <br />Based on the above facts and conditions, staff would suggest that: <br />1) The lot is buildable without a lot area variance because <br />we are allowed to credit the non-contiguous dry buildable across the <br />lagoon for a total of 1.7+ acres. <br />2) The actual area to be permanently credited should be <br />enough to bring the lot area up to either 0.8 or 1.0 acre and this: <br />crediting become a clause of the final resolution, so that any future <br />development of the northern portion of the property does not negate <br />this credit. (Planning Commission recommended no permanent credit <br />required.) <br />