NOTESSITE NOTES2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCEWITH OSHA REGULATIONS.2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE ANDTHIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGEBATTERIES.2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANYPLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTINGAND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED INACCORDANCE WITH SECTION NEC 110.26.2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, ANDMAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVEDMANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGSERVES TO PROTECT THE BUILDING OR STRUCTURE.EQUIPMENT LOCATIONS2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS INACCORDANCE WITH NEC 110.26.2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BERATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BYNEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PVMODULES IN ACCORDANCE WITH NEC 690.34.2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THEINVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIEDPERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES.2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATEDFOR OUTDOOR USAGE WHEN APPROPRIATE.STRUCTURAL NOTES2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED INACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHEREDGE OF THE ARRAY/SUB-ARRAY, IN ACCORDANCE WITH RAILMANUFACTURER’S INSTALLATION PRACTICES.2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'SSPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED& SEALED PER LOCAL REQUIREMENTS.2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BECOMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PERCODE BY A LICENSED CONTRACTOR.2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NOGREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKINGMANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE.2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILLBE STAGGERED AMONGST THE ROOF FRAMING MEMBERS.WIRING & CONDUIT NOTES2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FORTHEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ONMINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMITUP-SIZING.2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USEDIN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTINGOR LABELING PER NECGROUNDING NOTES2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTEDFOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TOTHE ELEMENTS SHALL BE RATED FOR SUCH USE.2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCEWITH NEC 690.43 AND NEC TABLE 250.122.2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING,AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCEWITH NEC 250.134 AND 250.136(A).2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZEDIN ACCORDANCE WITH NEC 690.45 AND INVERTERMANUFACTURER'S INSTALLATION PRACTICES2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN INMANUFACTURER DOCUMENTATION AND APPROVED BY THEAHJ.2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BEARRANGED SUCH THAT THE REMOVAL OF A MODULE DOESNOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHERMODULE.2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG ORLARGER PER NEC 250.1192.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITHNEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTINGSYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDINGELECTRODE SYSTEM PROVIDED IN ACCORDANCE WITH NEC250, NEC 690.47 AND THE AHJ.2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDSDISCONNECTION AND OVERCURRENT PROTECTION NOTES2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THATWHEN THE SWITCH IS OPENED THE CONDUCTORS REMAININGENERGIZED ARE CONNECTED TO THE TERMINALS MARKED“LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLEBUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TOREDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS INACCORDANCE WITH 690.122.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDINGTO NEC 690.8, 690.9, AND 240.2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TOA SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) INACCORDANCE WITH NEC 110.3(B).2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDEARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC690.11 AND UL1699B.INTERCONNECTION NOTES2.7.1 LOAD SIDE INTERCONNECTION SHALL BE INACCORDANCE WITH NEC 705.12.2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTERCONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OFBUSBAR RATING PER NEC 705.12.2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THEOVERCURRENT DEVICE PROTECTING THE BUSBAR SHALLNOT EXCEED 120 PERCENT OF THE AMPACITY OF THEBUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BELOCATED OPPOSITE END OF THE BUS FROM THE UTILITYSOURCE OCPD PER NEC 705.12.2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUTCOMBINER PANEL, TOTAL RATING OF ALL OVERCURRENTPROTECTION DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTIONDEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC705.12.2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) INACCORDANCE WITH NEC 705.12.2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCEWITH TO NEC 705.12 WITH SERVICE ENTRANCECONDUCTORS IN ACCORDANCE WITH NEC 230.42.2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWERSOURCES OUTPUT IS EXEMPT FROM ADDITIONALFASTENING PER NEC 705.12.GENERAL NOTESPV-056/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NAUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213