Laserfiche WebLink
MGL1L2NLINELOADL1L1L2L2 (N) UTILITY ACDISCONNECT 1 OF 2100A VISIBLE-OPEN TYPE,LOCKABLE, READILYACCESSIBLE ANDNON-FUSIBLE, 240V,NEMA 3R, UL LISTEDGL1L2NGL1L2N(N) PV PRODUCTIONMETER, UTILITY OWNED, NEMA 3R, UL LISTED200A RATED, 1-PHASE,3-WIRE, 120/240VW/ BYPASS HANDLE2TO SYSTEMCONTROLLERAC ~DC ±BATTERY+-L2L1GL2L1G(N) ENPHASEIQBATTERY-5P-1P-NABATTERYAC ~DC ±BATTERY+-L2L1GL2L1G(N) ENPHASEIQBATTERY-5P-1P-NABATTERYGN70A/2P60A/2P100A/2P200A FACTORY WIRINGNFT (AUTOTRANSFORMER)IQ BATTERY(80A MAX)IQ COMBINERGENERATOR(80A MAX)(N) ENPHASE SYSTEM CONTROLLER 3G200A, NEMA 3R, 120/240VN/C3N/C4WIRELESSCOMMSGERIQ COMBINERIQ BATTERY(N) ENPHASERAPIDSHUTDOWNSWITCH(4) #12 AWG THWN-2(1) 3/4" EMT CONDUIT230A/2PG30A/2P(2) #10 AWG THWN-2(1) #10 AWG THWN-2GRND3/4" EMT CONDUITGNE(2) #6 AWG THWN-2(1) #10 AWG THWN-2 GRND3/4" EMT CONDUIT (N) UTILITY ACDISCONNECT 2 OF 2100A VISIBLE-OPEN TYPE,LOCKABLE, READILYACCESSIBLE AND NON-FUSIBLE,240V, NEMA 3R, UL LISTED(N) 100A ESSCOMBINER PANEL,NEMA 3R, ULLISTED, 240V(N) 100A/2P MAINBREAKER, 240V20KWGENERATOR(E) 200A MAINDISTRIBUTION PANEL,W/ (E) 200A/2P MAINBREAKER, 240V(BACKUP LOAD PANEL)(E) 200A/2P MAINBREAKER, 240VMETER #: 9999996L2NL2L1TO UTILITY GRID(E) BI-DIRECTIONAL UTILITYMETER 1-PHASE, 3-W,W/ BYPASS HANDLE, CL320120V/240VMLINELOADGN(E) 400A METERMAIN PANEL, 240VEXISTING GROUNDINGELECTRODE SYSTEM2X (E) 200A/2P MAINBREAKERS, 240VGN(E) 200A MAIN DISTRIBUTIONPANEL, W/ (E) 200A/2P MAINBREAKER, 240V(NON-BACKUP LOAD PANEL)(E) 200A/2P MAINBREAKER, 240VEE3CONSUMPTION CT'sENPHASE CTRL-SC3-NA-01CONTROL CABLEGENERATOR CTGN20A/2PIQ GATEWAY15A/2P(N) ENPHASE COMBINER PANELNEMA 3R, UL LISTED,125A RATEDCELLMODEMWIRELESSCOMMS10A OR 15A BREAKER ISSUITABLE FOR USE20A/2P20A/2P20A/2P#12 AWGENPHASE QCABLE(S)JINKO SOLAR JKM425N-54HL4-B (425W)11 MICROINVERTERS IN STRING 111 MICROINVERTERS IN STRING 210 MICROINVERTERS IN STRING 310 MICROINVERTERS IN STRING 41(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDENPHASE IQ8PLUS-72-2-US (240V)MICROINVERTERS ONE UNDEREACH PANEL (240V)L2L1GL2L1(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDL2L1GL2L1#6 AWG BARE CUROMEX CAN BE USED IN LIEU OF CONDUIT FOR INTERIOR BUILDING AND ATTICRUNS ONLY. DO NOT USE ROMEX IN CONDUIT OR OUTDOOR ENVIRONMENTS.21(ENPHASE X-IQ-AM1-240-5/5C)PV-046/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NAELECTRICALDIAGRAMAMBIENT TEMPERATURE SPECIFICATIONSRECORD LOW TEMP-27°CAMBIENT TEMP (HIGH TEMP 2% AVG.)32°CMINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE7/8"SOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #JINKO SOLAR JKM425N-54HL4-B (425W)VMP32.37 VIMP13.13 AVOC38.95 VISC13.58 ATEMP. COEFF. VOC-0.25 %/°CWIRE IDEXPECTEDWIRE TEMP (°C)TEMPDERATE(90 °C)QTY OF CURRENTCARRYINGCONDUCTORSCONDUIT FILLDERATEMINIMUMCONDUIT SIZE(TBD ON SITE)WIRE GAUGE &TYPECONDUCTORAMPACITY @90°C (A)CONDUCTORAMPACITY @75°C (A)REQUIRED CIRCUITCONDUCTOR AMPACITY(A)ADJUSTED CONDUCTORAMPACITY @ 90 °C (A)NEUTRALCONDUCTORSIZE & TYPEGROUND WIRESIZE & TYPE1320.964 /40.83/4''#10 THWN-2403516.6430.72NONE#10 THWN-22320.96211''#4 THWN-2958563.5391.20#4 THWN-2#8 THWN-23320.96212''#3/0 THWN-2225200200.00216.00#3/0 THWN-2#4 THWN-2DESCRIPTIONFORMULARESULTPV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25 = (42 x 1.21)A x 1.2563.53A (SELECTED OCPD = 70A)UTILITY DISCONNECT TO BE LOCATEDWITHIN 10' OF MAIN SERVICE/BILLING METERALL EQUIPMENT RATED FOR SINGLE PHASENOTE:1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONALPROTECTIVE EQUIPMENT3. THE PRODUCTION METER AND AC DISCONNECT SHOULD BE LOCATED TOGETHER IN AREADILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN SERVICE METER4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL ENERGYEQUIPMENT5. NOTE ALL THE APPLICABLE NEC CODES6. SHOW ALL THE SYSTEMS INCLUDING STORAGE, EXISTING AND NEW (IF APPLICABLE)7. SERVICES <320A WILL USE SELF-CONTAINED MAIN SERVICE METERS. 320A SERVICES MUSTINDICATE WHETHER THE METERING WILL BE SELF-CONTAINED OR TRANSFORMER METERED.ALL SERVICES 400A OR GREATER MUST BE TRANSFORMER METERED8. PRODUCTION METER LOCATED WITHIN 10 FT OF METER9. WIRES LOCATED IN READILY ACCESSIBLE LOCATIONS SHALL BE GUARDED PER NEC690.31(A)10. CONDUIT TO BE UL LISTED FOR WET LOCATIONS AND UV PROTECTED (EX. -EMT,PVC ORRMC) *FMC MAY BE USED IN INDOOR APPLICATIONS WHERE PERMITTED BY NEC ART. 34811. VISIBLE LOCKABLE AND LABELED DISCONNECT IS LOCATED WITHIN 10FT OF METER12. THE INVERTERS ARE UL1741 CERTIFIEDPOC/RPAMICROINVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ8PLUS-72-2-US (240V)INPUT POWER RANGE235W-440WMIN/MAX START VOLTAGE22V/58VNOMINAL AC VOLTAGE240VMAX CONT. OUTPUT CURRENT1.21AMAX CONT. OUTPUT POWER290WMAX MODULES PER STRING13 (13 MICROINVERTERS)UTILITY HAS 24/7 UNESCORTED KEYLESSACCESS TO ALL METERS AND DISCONNECTSUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213UTILITY PV AC DISCONNECTPLACARD LOCATION: AT UTILITY AC DISCONNECTPHOTOVOLTAICSYSTEM CONNECTEDPLACARD LOCATION: AT MAIN SERVICE PANELNOTES:·MADE OF WEATHERPROOF & DURABLE MATERIALSUCH AS HARD PLASTIC OR METAL·PERMANENTLY ATTACHED TO THE METER SOCKETWITH SCREWS OR RIVETS·YELLOW BACKGROUND WITH BLACK LETTERING·AT LEAST 1-½” HIGH BY 3” WIDE WITH ARIAL BOLD FONTNOTES:·MADE OF WEATHERPROOF & DURABLE MATERIALSUCH AS HARD PLASTIC OR METAL·PERMANENTLY ATTACHED TO UTILITY AC DISCONECTWITH SCREWS OR RIVETS·YELLOW BACKGROUND WITH BLACK LETTERING·AT LEAST 1-½” HIGH BY 3” WIDE WITH ARIAL BOLD FONT