All wiring Shall have not less than 600 volt insulation and all power wiring <br />and bus shall be in compl.-te conformity with the National Electric Code and <br />M State and local and NF.MA Electrical Standards. Control wiring shall be color <br />i coded. All field connections and connections required to conveniently replace <br />control components shall be made at approved type terminal blocks with en- <br />graved bakelite marker strips. Complete wiring diagrams shall be prepared <br />specifically for this project and submitted for approval along with technical <br />data on components. <br />35,1no.9.i. Equipment_ The control shall have the following equipment, fea- <br />tares and construction: <br />I. Fused main disconnect with fuses sized as shown on the plan. Disconnect <br />shall he suitable as a service entrance disconnect switch. <br />2. Auxiliary power manual transfer switch, rotary tvpe or equal. <br />3. Provide on the side of the control panel an Appleton #AE-1041 RS, 4 wire, <br />4 pole, 100 amp, 230 volt auxiliary power receptable. <br />4. Terminal blocks for power, pumpa, floats and future telephone line <br />connections. <br />5. A lightning arrestor shall be supplied in the control and connected to <br />each line of the incoming side of the power input terminals. The nrrc,,tor <br />shall protect the control against damage due to lightning strikes on the <br />incoming power line. Arrestor shall be of the solid-state type, designed <br />to clamp within 20 microseconds under high level transient surge. Thyrite <br />or carbon type arrestors are not acceptable. contractor shall connect a <br />suitable earth ground to ground lug in enclosure, as required by the <br />National Electric Code. <br />6. The control center shall include a three phase monitor/control connected <br />to the incoming side of the power input terminals. The unit shall provide <br />instantaneous drop -out protection in the event of phase, unbalance, phase <br />loss, phase reversal, incorrect phase .egnence or low line voltage (under <br />1.� <br />voltage). The phase monitor shall include automatic reset circuitry and a <br />time delay to prevent drop -out ,iiie to momentary transients. <br />7. A thermal magnetic molded case circuit breaker ("F" frame or better) shall <br />be supplied as branch circuit protection for each pump motor. <br />8. A full voltage across the line magnetic mot, or starter with <br />ambient -compensated, quick -trip overload sensing in each phase to provide <br />over current and running protection for eakh pump lnot•)r. -)ver current <br />protection shall be provided by accurately sized replaceable hest-r <br />elements. Units requiring replacement of completo overload block to match <br />motor current are not acceptable overload reset +hall extend through <br />inner panel door. Auxiliary contacts shall he provided for the control <br />functions specified. <br />1i,100- <br />0-584Ic <br />Copyright 1Q83 <br />Ronestroo, Rosene, An.ierlik <br />4 Associates, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.