My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution 894
Orono
>
Resolutions
>
Resolution 0001-7547
>
Reso 0800 - 0899 (June 27, 1977 April 13, 1978)
>
Resolution 894
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2015 3:12:21 PM
Creation date
11/13/2015 3:12:21 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
`PART V - OONSTRUCTIQV AND MkTERIAL SPECIFICATIONS <br />�SECTICN 1 - CONSTRUCHON PROCEDURES <br />M <br />1. PROTECT ABSORPTIQN AREAS: Proposed drainfield absorption areas shall be identified <br />and marked off on the lot at the time of the site evaluation and prior to any <br />construction or grading occurring in the area. The drainfield area shall remain <br />undisturbed until drainfield construction is commenced. No vehicular traffic should <br />-be allowed in the drainfield area either before or after drainfield installation. <br />2. FAVORABLE MATHER REQUIRED: Drainfield absorption area or trench construction must <br />not proceed if the area is wet or has had rain within 48 hours. Once construction <br />'commences, it should proceed to completion without interruption unless rain or <br />ground moisture causes the trench sides to smear or the ground to compact under the <br />equipment. No construction shall occur in frozen ground. Rain or snow should not <br />be allowed to acevumilate on uncovered trenches. <br />3. EQUIPMENT RESTRIMONS: Equipment used for drainfield construction shall be chosen <br />to cause minimum compaction of surface soil. Tracked equipment is preferred over <br />wheeled equipment. Trenching equipment is best sized to produce the required <br />trench width in one pass to reduce smearing. Trench -side scarifying is important <br />and must be -done either with the trench -cut, -or by hand following the cut. . <br />4. INSPECTION NOTICE: The City of Orono shall be notified at least 24 hours in <br />advance of any septic system construction start, and shall also*be notified when <br />construction recommences after having been stopped for 24 hours or longer. <br />-22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.