Laserfiche WebLink
16' - 6 7/8"8' - 11 15/16"2' - 3"1' - 1 1/4"1' - 1 1/4"8' - 7 1/4"8' - 7 1/4" <br />2' - 3" <br />OVERHANG <br />OVERHANG <br />OVERHANG <br />OVERH <br />A <br />N <br />G <br />OVERHANG <br />1' - 0"0' - 4" <br />5' - 10 1/4"21' - 8 1/2"5' - 10 1/4"63' - 0 15/16"5' - 7 7/16"15' - 9 1/2"16' - 1 11/16"18' - 3 7/16"4' - 5 3/16"7' - 5 3/16"22' - 3"7' - 5 1/4"37' - 11 5/8" <br />18' - 2 7/8"8' - 5 13/16"22' <br />- <br /> 10 <br /> 13 <br />/16 <br />"23' <br />- <br /> 3 <br /> 13 <br />/16 <br />"20' - 3 9/16"14' - 2 7/16"18' - 2 13/16"6' - 11 3/8"14' - 2 7/16"3' - 6 3/16"4' - 8 11/16"1' - 3 1/16"2' - 3"2' - 3"NEW <br />CHIMNEY OVERHANG <br />OPENINGS <br />IN EAVE <br />AND SOFFIT <br />OPENINGS <br />IN EAVE <br />AND SOFFITOPENINGS IN EAVE AND SOFFIT4' - 6"4' - 6"4' - 6"3' - 6"4' - 6"4' - 6"4' - 6"4' - 6"2' - 9 3/8"OPENINGS <br />IN EAVE <br />EXISTING <br />CHIMNEY <br />OVERHANG <br />OVERHANG <br />OVERHANG <br />OVERHANG <br />OVERHANG <br />OVERHANG <br />OVERHANG <br />OVERH <br />A <br />N <br />G <br />OVERH <br />A <br />N <br />G <br />OVERHANG <br />OVERHANG <br />OVERHANG <br />EXISTING METAL <br />ROOFING TO BE <br />REMOVED AND <br />REPLACED2' - 3"OVERHANG0' - 4"0' - 6"0' - 0"1' - 8 1/4" <br />1' - 8 1/4" <br />1' - 8 1/4" <br />117 <br />. <br />0 <br />0 <br />°90.00°90.00° <br />2' - 5" <br />2' - 5" <br />2' - 0"55' - 10 1/8"96' - 5 15/16" <br />33' - 5" <br />37' - 1 7/16"30' - 4 1/2"19' - 8 <br />3 <br />/ <br />8" <br />29' - 1 <br />1 <br />7/ <br />8"Copyright 2024 DJR Architecture, Inc.C B AD <br />4 <br />3 <br />2 <br />1 <br />Project #: <br />Date: <br />Integrated Design, Drawings, Project Mgmt by: <br />Marco Vincent | Takka Day Design | 651.336.8885 <br />NOT FOR <br />CONSTRUCTION <br />NOT FOR CONSTRUCTIONE <br />A08aRoof PlanEnter address hereProgress Set 29 <br />5/16/2025 <br />865 Partenwood 1/4" = 1'-0"1Roof Plan <br />3"/12" <br />3"/12" <br />3"/12" <br />3"/12"4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />4"/12" <br />3"/12" <br />3"/12" <br />3"/12" <br />3"/12"3"/12" <br />4"/12" <br />1.25" <br />/ 12" <br />*FINAL <br />SLOPE <br />TBD* <br />1.25" <br />/ 12" <br />*FINAL <br />SLOPE <br />TBD* <br />ROOFING 3/12 AND 4/12 SLOPES: <br />CEDAR SAWED BLUE LABEL SHINGLES <br />APPLIED PER CEDAR SHAKE & SHINGLE BUREAU (LOW SLOPE) <br />ROOF DECK: 5/8" CDX PER APA <br />GRACE ICE & WATER SHIELD THROUGHOUT W/ ADDITIONAL <br />HEAT RESISTANT PRODUCT BENEATH ANY SOLDERED METAL <br />AREAS <br />CEDAR SHAKE BREATHER 3D MATRIX FOR AIR GAP. INSTALLED <br />PER MFCTR. <br />STAINLESS STEEL FASTENERS <br />1 Revision 1 Date 1 <br />SHERIDAN METAL SOLDERING <br />AT SLOPES 2/12 OR FLATTER <br />AND AT CONDITIONS BUBBLED <br />ON DRAWING. FOR BID, CONSULT <br />GC FOR ESTIMATING SF OF SOLDERED <br />SURFACES <br />3"/12" <br />3"/12" <br />3"/12" <br />ALL EXISTING ROOFING AND ROOF <br />STRUCTURE TO BE REMOVED AND REPLACED <br />EXCEPT GARAGE ROOF <br />SOFFIT: <br />FLAT SOFFIT FOR ALL 4:12 SLOPES (MAIN ROOF <br />AND GARAGE ROOF) <br />NO FLAT SOFFIT FOR OTHER ROOF OVERHANGS <br />(CUPOLAS AND DORMERS) <br />176