Laserfiche WebLink
N <br />O <br />N <br />N <br />tX <br />3 <br />w <br />� J <br />H <br />0 <br />a)Ln <br />v Ln <br />�rn <br />� M <br />C <br />6D i <br />�z <br />w <br />aQ <br />Lr u <br />N <br />O 0 <br />N O <br />U <br />00 <br />�o <br />_1C <br />C M <br />O1 c-I <br />X <br />a <br />06 N <br />�0 <br />oz <br />o � <br />mo <br />M. <br />AC <br />Air Cock <br />Pipe & Joint Designations <br />FIRST LETTER <br />SUCCEEDING LETTERS <br />PIPING SYSTEM DESIGNATION <br />FLUID <br />PDT NO. <br />PIPE MATERIAL <br />FITTING MATERIAL <br />A <br />Aeration <br />O <br />BP <br />—I I <br />T <br />b <br />Air Operation <br />Backflow Preventer <br />Blind Flange <br />Drip Trap <br />Exhaust to Atmosphere (Inside) <br />Atmosphere <br />Exhaust to ) Outside <br />p ( <br />AE <br />Bell &Spigot Joint <br />Flanged Adapter <br />g p <br />Flanged Joint Fitting <br />Mechanical Joint Fitting <br />Wall Pipe <br />Wall Sleeve <br />MEASURED OR INITIATING <br />VARIABLE <br />MODIFIER <br />READOUT OR <br />PASSIVE FUNCTION <br />OUTPUT FUNCTION <br />MODIFIER <br />CA <br />Compressed Air <br />1 <br />Class (as Specified) for Ductile Iron ANSI <br />A21.51/AWWA C151 Flanged or <br />Mechanical Joints as Indicated. Class (as <br />Specified) for Threaded Flange <br />Class 125 Ductile or Cast Iron, ANSI A21.10/AWWA <br />C110 Flanged or Mechanical Joint as Indicated <br />CG <br />Chlorine Gas <br />CS <br />Chlorine Solution <br />Analysis <br />Alarm <br />DG <br />Digester Gas <br />B <br />B <br />Burner Flame <br />IDS <br />Digester Sludge <br />C <br />Conductivity <br />(Electrical) <br />Control <br />FC <br />Ferric Chloride <br />2 <br />Standard Weight Carbon Steel, ASTM <br />A120, Black <br />3-Inch and Smaller - 150 lb. Malleable Iron, ANSI <br />B16.3 Banded, Screwed, 3-1/2 Inch and Larger - <br />Standard Weight -ASTM A234 ANSI B16.9 Welded <br />g <br />Steel or 125 lb. Flanged Cast Iron as Indicated <br />GW <br />Grit Washing <br />D <br />Density (Mass) or <br />Specific Gravity <br />Differential <br />GS <br />Grit Separation <br />HW <br />Hot Water <br />E <br />Voltage (EMF) <br />Primary Element <br />LR <br />Lagoon Return <br />NG <br />Natural Gas <br />FT <br />FC <br />Flame Trap <br />Flame Cell <br />Flanged Coupling Adapter (F.C.A.) <br />� <br />�— <br />Quick Disconnect Coupling <br />Reducer <br />Removable Cap <br />F <br />Flow Rate <br />Ratio (Fraction) <br />NP <br />Non -Potable Water <br />3 <br />Standard Weight Carbon Steel, ASTM <br />A120, Galvanized <br />3-Inch and Smaller- 150 lb. Malleable Iron, ANSI <br />B16.3 Banded, Screwed, Galvanized 3-1/2 Inch and <br />Larger - 125 lb. Cast Iron Flanged or Mechanical <br />Coupling as Indicated <br />G <br />Gauging (Dimensional) <br />Glass <br />NR <br />Noxic Return <br />P <br />Polymer <br />H <br />Hand (Manually <br />Initiated) <br />High <br />PD <br />Plant Drain <br />PP <br />Process Piping <br />-�f�--I <br />Flexible Hose <br />Removable Plug <br />I <br />Current (Electrical) <br />Indicate <br />PS <br />Primary Sludge <br />O 4 F.D. <br />HB <br />-0Q� <br />FE <br />X <br />O <br />N.C. <br />Floor Drain -Size <br />Harnessed Sleeve Coupling (H.S.C.) <br />Sleeve Coupling (S.C.) <br />Hose Bib <br />1-1/2 Hose Gate <br />Meter <br />Motor Operation <br />Normally Closed <br />ST <br />I--O—� <br />Rupture Disc <br />Sediment Trap <br />Sight Flow Indicator <br />Union <br />4 <br />Copper ASTM B88 Buried Service - Type <br />K, Soft Temper Exposed Service - Type L, <br />Hard Temper <br />Wrought Copper or Cast Bronze Solder Joint, ANSI <br />B16.22, 150 psi <br />PW <br />Potable Water <br />J <br />Power <br />Scan <br />R <br />Recirculation <br />K <br />Time or <br />Time -Schedule <br />Control Station <br />RAS <br />Return Activated Sludge <br />L <br />Level <br />Li <br />Light Pilot <br />g (Pilot) <br />Low <br />S <br />Sample <br />5 <br />Polyvinyl Chloride, Schedule 80, Normal <br />Impact ASTM D1785 <br />Schedule 80 Polyvinyl Chloride, Socket Solvent Weld <br />Joints, ASTM D2467 <br />SC <br />Scum <br />M <br />Moisture or Humidity <br />Middle or <br />Intermediate <br />SD <br />Sanitary Drain <br />SN Supernatant <br />Fiberglass Reinforced Plastic (FRP) ASTM <br />SR Sludge Recirculation 6 D2996 <br />SS Secondary Sludge <br />ST Sludge Transfer Linear Low Density Pol eth lene <br />Y Poly -ethylene <br />UW Utility Water (Non -Potable Plant Water) 7 Tubing,Vacuum Rated Installed Inside <br />WAS Waste Activated Sludge 3" Schedule 80 PVC Pipe <br />Epoxy Resin Fragment Wound or Molded Type - 150 <br />psi @ 200 F <br />Compression Fitting <br />N <br />0 <br />Orifice (Restriction) <br />P <br />Pressure or Vacuum <br />Point (Test) <br />Connection) <br />N.O. <br />Normally Open <br />Q <br />Quantity or Event <br />Integrate or Totalize <br />Meter <br />WW <br />Waste Water <br />�il__ <br />Orifice <br />8 <br />Cast Iron Soil ANSI A112.5.1, Service <br />Weight, Bell and Spigot or Hubless <br />Cast Iron Soil ANSI A112.5.1, Service Weight, Bell <br />and Spigot or Hubless <br />R <br />Radioactivity <br />Record or Print <br />OPump <br />DESIGNATION <br />EQUIPMENT TYPE <br />S <br />Speed or Frequency <br />Switch <br />F <br />Fan <br />9 <br />Class (as Specified) for Ductile Iron ANSI <br />A21.51/AWWA C151, Bell and Spigot <br />Class 125 Ductile or Cast Iron, ANSI A21.10/AWWA <br />C110, Mechanical Joint <br />T <br />Temperature <br />Totalizing <br />Transmit <br />U <br />V <br />Viscosity <br />Valve, Damper <br />or Louver <br />ME <br />P <br />Miscellaneous Equipment <br />Pump <br />10 <br />Polyvinyl Chloride Sewer Pipe, Bell and <br />Spigot ASTM D-3034 <br />Polyvinyl Chloride, Bell and Spigot, ASTM D-3034 <br />W <br />Weight or Force <br />Well <br />Process <br />FIOW <br />Diagram <br />Plan <br />Process <br />Drawings <br />S <br />SG <br />Special <br />Stop Gate, shear gate, sluice gate, <br />slide gate, flap gate <br />11 <br />Standard Weight Steel, ASTM A53, <br />Seamless. (10 Mil Polyethylene or PVC <br />Coated @ Exterior) <br />Standard Weight, Butt Weld Steel ANSI B16.9 ASTM <br />A234 <br />X <br />Y <br />Relay or <br />Compute <br />® <br />Angle Valve <br />Ball Valve <br />Ball Valve <br />Butterfly Valve <br />UH <br />V <br />Unit Heater <br />Valve (Valves 4" Diameter and <br />12 <br />Polyvinyl Chloride Pressure Pipe ASTM <br />D2241 (C900) with Bell & Spigot Ends. <br />Wall thickness as Specified <br />Class 125 Ductile Iron or ANSI A21.10/ AWWA C110, <br />Flanged or Mechanical Joints as Indicated <br />Z <br />Position <br />Drive, Actuate <br />or Unclassified <br />Final Control <br />Butterfly Valve <br />Check Valve <br />Element <br />Larger Included in Schedule <br />13 <br />Polypropylene, ASTM D2146 Schedule <br />40 with Heat Fused Joints <br />Polypropylene, Schedule 40 Drainage Type with <br />Heat Fused Socket Joints <br />Check Valve ® Gate Valve <br />Diaphragm Valve <br />Plug Valve <br />14 <br />Stainless Steel AISI Type 304, ASTM <br />A312 Schedule 5S <br />Stainless Steel AISI Type 316 ANSI B16.9 <br />Butt -Welded Schedule 5S or 150 lb Flanged <br />Gate Valve <br />Identification Letters (See Table) <br />Welded Steel, AWWA C200 with <br />ASTM A234, Grade B, Seamless or Butt -welded. <br />® <br />Globe Valve <br />FE <br />3 <br />15 <br />Specified Wall Thickness. Epoxy/Cement <br />Mortar Lined for Potable Water Service <br />Fittings 14-inches and Larger Mitered to Conform to <br />AWWA C208 Table 2 with Butt -Weld Ends <br />®ZI <br />Hose Gate Valve <br />Equipment Number <br />® <br />Knife Gate Valve <br />Needle Valve <br />Instrument Number <br />ME - DS - 2 <br />Piping System <br />16 <br />Class (as Specified) for Ductile Iron ANSI <br />A21.51/AWWA C151 Glass Lined Flanged <br />or Mechanical Joints as Indicated Class <br />(as specified) for Threaded Flange <br />Class 125 Ductile or Cast Iron ANSI A21.51/AWWA <br />C151 Glass Lined Flanged or Mechanical Joints as <br />Indicated <br />0 <br />Schedule Identification <br />®_ <br />Pinch Valve <br />Locally Mounted Mounted On <br />® <br />Plug Valve <br />Instrument Board <br />D®4 <br />RPZ (Reduced Pressure Zone) <br />(1) SECTION CUT ON DRAWING M-1 AS: <br />PRV <br />PT <br />Pressure Regulating Valve2(2 <br />Pressure/Temperature Relief Valve <br />E For Existing, F For Future, Blank for Construct <br />Line Number (Sequentially Numbered) <br />SECTION NUMBER - 2 <br />M-2 DRAWING ON WHICH <br />SECTION APPEARS <br />O Cylinders HW Handwheel <br />Relief or SafetyValve <br />CW <br />O <br />Chainwheel L Lever <br />O <br />EF 6 - IDS - 1 1 <br />( ) <br />(2) ON DRAWING M-2 THIS SECTION IS IDENTIFIED AS: <br />E-3 <br />Shear, Slide, Sluice or Stop Gate <br />O <br />Diaphragm O Motor <br />Piping Design Table <br />SECTION NUMBER 2 SECTION <br />M-1 DRAWING ON WHICH <br />3-Way Plug Valve (2-Port) <br />O <br />Electric O Pneumatic <br />Piping System (See Piping Schedule) <br />Pipe Size In Inches <br />SECTION WAS TAKEN <br />3-Way Plug Valve (3-Port) <br />O <br />Float O Solenoid <br />(1) DETAIL CALL OUT ON DRAWING M-2 AS: <br />3-Way Valve <br />O <br />Hydraulic <br />DETAIL NUMBER 1 <br />3-Way Plug Valve (4-Port) <br />(1) <br />DETAIL CALL OUT ON DRAWING M-2 AS: <br />M-1 DRAWING ON WHICH <br />DETAIL IS SHOWN <br />--V-- <br />Vent <br />Yard Hydrant <br />STANDARD <br />DETAIL NUMBER 1 <br />M-1 DRAWING ON WHICH <br />DETAIL IS SHOWN * <br />(2) ON DRAWING M-1 THIS DETAIL IS IDENTIFIED AS: <br />DETAIL NUMBER 1 DETAIL <br />M-2 DRAWING ON WHICH DETAIL <br />IS CALLED OUT <br />Soil Boring <br />Y-Type Strainer <br />* <br />NOTE: IF PLAN AND SECTION (OR DETAIL CALL -OUT <br />AND DETAIL) ARE SHOWN ON THE SAME DRAWING, <br />DRAWING NUMBER IS REPLACED BY A LINE. <br />I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED <br />BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED <br />PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF MINNESOTA. <br />1960 PREMIER DRIVE <br />MANKATO, MN 56001 <br />BOLTON <br />Phone: (507) 625-4171 <br />Email: Mankato@bolton-menk.com <br />° www.bolton-menk.com <br />8c MENK <br />DESIGNED <br />DP <br />NO. <br />ISSUED FOR <br />DATE <br />O RO N O, M I N N ESOTA <br />SHEET <br />1.03 <br />DRAWN <br />sWP <br />WATER TREATMENT FACILITY <br />CHECKED sP <br />LEGEND <br />SIGNER'S NAME <br />LIC. NO. XXXXX DATE X/XX/XXXX <br />CLIENT PROJ. NO. <br />24X136758000 <br />66 <br />