My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinances 1st series - 150
Orono
>
Ordinances
>
Ord 1s and 2nd Series (historical)
>
Ordinances 1st Series (1-150 Microfiche)
>
Ordinances 1st Series 150 - 253
>
Ordinances 1st series - 150
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/26/2015 2:51:32 PM
Creation date
9/4/2025 3:21:59 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
13 <br /> LARGE GENERAL SERVICE (Contd) <br /> Parallel Operation Interconnection and parallel operation of Customer's inde- <br /> � pendent source of power (Custamer's system) and Company's service (Company's <br /> system) will be permitted by Company under the following conditions: <br /> l. The interconnection between the systems must be at 12,�+00 vol�;s or <br /> higher at a point on Company's system where Customer's operations will <br /> not interfere with the quality of Company's service to any of its other <br /> customers. <br /> 2. Customer agrees to provide the necessary equipment as approved by <br /> Company to enable Customer to operate its generating equipment in parallel <br /> with Company's system. Since the power factor and the voltage at which <br /> Company's system and Customer's system are operated will vary, each party <br /> agrees to operate its system at such power factor and voltage as is condu- <br /> cive to best operating standards and in such manner as to absorb its share <br /> of the reactive power. <br /> 3. Company reserves the right to disconnect service in the event service <br /> to Customer results in trouble on Company's system such as interruptions, <br /> grounds, radio or telephone interference, surges or ob�ectionable volta�e <br /> fluctuations, where such trouble is caused by negligence of Customer if, <br /> after giving notice in writing to Customer of such trouble, Customer fails <br /> to remedy the causes thereof within a reasonable time. <br /> �+. Company's meters will be ratcheted to measure the flow of power and <br /> energy from Company to Customer only. Reverse flow if any will be ignored <br /> unless the amount is substantial in which event it will be a matter for <br /> negotiation and further agreement between the parties. <br /> AA <br />
The URL can be used to link to this page
Your browser does not support the video tag.