12 <br /> LARGE GENERAL SERVICE (Contd) <br /> Determination of Demand The demand in kilovolt-amperes for billing purposes <br /> shall be determined by dividing the maximum demand in kilowatts by the <br /> monthly average power factor and shall be rounded to the nearest whole kva, <br /> but in no month shall the demand to be billed be considered as less than <br /> 50°� of the greatest demand in kva billed during the preceding eleven months <br /> nor in any event less than 100 kva. <br /> Maximum Demand The ma�imum demand in kilowatts shall be the greatest 15-minute <br /> load during the month for which bill is rendered. <br /> Average Power Factor The average power factor is defined to be the quotient <br /> obtained by dividing the kilowatt-hours used during the month by the square <br /> root of the sum of the squares of the kilowatt-hours used and the lagging <br /> reactive kilovolt-a�pere-hours supplied during the same period. Any leading <br /> kilovolt-ampere-hours supplied during the period will not be considered in <br /> determining the average power factor. <br /> Minimum Demand to be Billed The monthly minimum billing demand shall not be <br /> less than provided above, whether or not energy is used. <br /> Standby and Supplementary Service <br /> Availability Available at 12,400 volts or higher to any large co�nnercial or <br /> industrial customer who normally supplies part or all of his electric power <br /> requirements from another inde�endent source of power for which the Company's <br /> service may be substituted wholly or in part. �ustomer shall contract for <br /> capacity adequate to supply the entire electric requirements for which such <br /> service may be used which capacity shall equal or exceed the agreed kva demand <br /> for standby to customer's other source of power. Company shall not be obligated <br /> to supply capacity in excess of that contracted for. <br /> Rate The billing shall be in accordance with Company's La.rge General Service <br /> rate schedule for Service at Primary Distribution Voltage except that the <br /> paragraph "Determination of Demand" shall be modified to read as follows: <br /> "The dema.nd in kilovolt-amperes for billing purposes shall be determined by <br /> dividing the maximum demand in kilowatts by the monthly average power factor, <br /> but in no month shall the demand to be billed be considered as less than the <br /> agreed standby demand plus 50�, of the �reatest excess demand in kva over such <br /> standby demand billed during the precedin� eleven months nor in ar�y event <br /> less than 2500 kva." <br /> (Continued on following sheet� <br /> AA <br />