Laserfiche WebLink
City of ORONO <br />RESOLUTION OF THE CITY COUNCIL <br />NO. <br />BEDROOM #1 <br />42. No smoke detector provide - UBC 1210 (a). <br />43. Windows: fire egressâ–şwindow not provided per UBC 1204. <br />44. Electrical: ceiling light not operable. <br />41. Receptacles outlets over 6' apart. <br />BEDROOM #2 - ATTIC <br />42. Aitic: used for bedroom - ceiling height not act-eptable - UBC <br />1207 (a). <br />43. Insulation: observed from exterior - snow melting off roof very <br />fast - sign of poor insulation. <br />44. Stairway: 2nd floor - improper guardrail height. <br />EXTERIOR <br />45. Ground Slope at Foundation: slopes toward structure. <br />46. Siding: weathered and deteriorating - UBC 1707 (a). <br />47. Soffit h Fascia: deteriorating - UBC 1707 (a). <br />48. Roofing: has moss on it and is deteriorating. Roof leaks and <br />has destroyed ceilings and walls. <br />49. Chimney: motar joints falling out - chimney in a state of <br />collapse - UBC 3704 (a). <br />50. Flashing & Vent Jacs: flashing around chimney improperly <br />installed - UBC 1701 (b). <br />51. Roof Ventilation: inadequate ventilation - only top ventilation <br />provided - UBC 3205 (c). <br />52. Garage: deteriorating. <br />Building is in a state of rieteriorat-on and dilapidation, thus it <br />is a safety and health 1iaLard pursuant to MinresotA Mate Building <br />Code/Uniform Building Code, Section 203. <br />Page 4 of 8 <br />