My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1983-06-30 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
C
>
Cristofori Circle
>
45 Cristofori Circle - 31-118-23-43-0012
>
Septic
>
1983-06-30 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2025 11:45:34 AM
Creation date
5/22/2025 11:38:08 AM
Metadata
Fields
Template:
x Address Old
House Number
45
Street Name
Cristofori
Street Type
Circle
Address
45 Cristofori Circle
PIN
3111823430012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 30, 1983 Job #i 1962 <br />Specifications, h300 Tayside Page 2 of 1t <br />TREATWIT AFEA: <br />A mound system treatment area will be constructed in the general location <br />shown on the attached location plan. The natural slope in this area is <br />approximately 6%. The mound configuration is indicated on the attached <br />General Mound Configuration sketch. Pertinent details are as follows$ <br />- ROCK BED. The rock bed shall be 61-8" wide by 60, long, placed on top <br />of the sand fill. 9" of rock shall be placed under the perforated <br />laterals and 2" of rock shall be placed on top of the perforated <br />laterals. The rock bed material shall be a clean rock, crushed igneous <br />rock, or similar insoluable, durable and decay resistant material, <br />free from dust, sand, silt, or clay. The size shall ran-e from 3A <br />inch diameter to 2 1/2 inch diameter. The rock bed shall be level. <br />- PERFORATED IA TERAL. The perforated laterals shall be 1 3A inch pipe <br />with 3/16 inch holes spaced 36 inches on center at the invert. Two <br />laterals will be installed, h0 inches on center and each 20 inches from <br />the edge of the rock bed. The perforated laterals shall be connected <br />by a 2" manifold pipe and shall be capped at the ends. The manifold <br />shall connect the perforated laterals either at one end or in the <br />center. The purpose of the manifold pipe is to distribute effluent <br />from the pumping chamber equally to the perforated laterals. Details <br />showing the manifold connection and can is sho:•m on the attached sketch, <br />"Tee to Tee Lateral - 'Manifold Construction". <br />S _ITD FILL. After preparation of the natural ground, a sand fill will be <br />placed as the base of the mound. The sand fill will extend at least <br />12 inches thick under the rock bed at its uphill location, and shall <br />be level with the top of tre rock bed, extending 18" beyond the rock bed, t <br />down on a 3:1 slope. The sand s;iall be composed by weight of at least <br />25% of very coarse, coarse, and medium sand varying in size from 2.0 <br />to 0.25 mni, less than 505, of fine or very fine sang ranging in size <br />between 0.25 and 0.05 mm, and no more than 10% of particles smaller than <br />0.05 mm. <br />RUITOFF DIVERSI)N. The mound shall be protected from surface runoff by <br />constructing a diversion dranage urhdli of the mound systen. The diversion <br />shall consist of cohesive fill extending 7 feet beyond the uphill side <br />of the mound at the center, uniformly extending, at the base, to the <br />corners of the mound as indicated on the attached General }'ound Config- <br />uration sketch. This diversion fill shall be compacted to 95% of the <br />standard proctor density according to ASV.: D-698, and shall form a <br />smooth surface to the top of the mound. <br />S10TY LOf�11 COVER. The sand fill and rock bed shall be covered vrith a <br />mound of loosly placed sandy loan fill, 12 inches deep at the center of <br />the rock bed and 6 inches deep at the edge of the rock bed, tapering <br />outvrard at a 3:1 slope. <br />TOPSOIL COVER. The entire mound and runoff diversion shall be covered <br />with 2 inches of topsoil suitable for growing grass. <br />?SOL COi,'�TRUCTION: <br />CO::.; C; ICI: A rubber -tired tractor nay be used for plok-ing or <br />disking, to prepare the soil surface but in no case shall a rubber -tired <br />tractor be used after the :,;;,rf ce preparation is co:�pleted. A cratitilcr or <br />track -type tractor shall be used for mound construction <br />TOM SMITH ASSOCIATES Inc <br />