Laserfiche WebLink
<br /> <br />RPUD Code Analysis: #LA25-000019 <br /> <br />Code <br />Section Sec. 78-626 RPUD Standard/Requirement Comment Conforming? <br />Yes/No <br />1 Minimum area: 5 acres or certain exceptions… <br /> <br />The property is 0.99 acres in area. However, Section 78-626(1)(b) may apply. The Council may find that the project conforms to <br />the exception under B, which reads: The property is directly adjacent to or across a public street from property which has been <br />developed previously as an RPUD or planned residential development and will be perceived as and will function as an extension <br />of that previously approved development. <br />Discuss <br />2 Uses. Single-family residential uses are conforming. Yes <br />3 Sewer availability Yes. Yes <br />4 Density. Each development in the RPUD district shall have a density within the range <br />specified in the comprehensive plan for the specific site. <br />The project is below the density guidance of the Comprehensive Plan. The 2040 CMP guides the property for Urban Low Density <br />Residential (3-8 units/acre). <br /> <br />No <br />5 Incentives. The city may utilize incentives to encourage the construction of projects which <br />are consistent with the city's housing goals. None requested. <br />6 Floor Area Ratio for low to medium density = 0.5 (FAR = total building floor area / total lot <br />area) No house plans have been provided. However, the FAR limitation is achievable. <br />Each RPUD site developed for single-family detached dwellings at medium density (i.e., densities ranging from 1 to 6 units/acre) shall be subject to the following standards (Section 78-626(8)): <br />8a Permitted Locations <br />The code contemplates single-family detached dwellings to be clustered to preserve significant natural features. The applicant <br />proposes two individual ½ acre, single-family detached homes. The project does not involve clustering or creation of a common <br />open space outlot. <br /> <br />No <br />8b Minimum SFR lot size: 15,000 square feet. The proposed lots will each be approximately 22,000 square feet. Yes <br />8c Minimum lot width at the setback line: 90 feet. The applicant’s proposal shows 100-feet of lot width for each lot at the building setback line. Yes <br />8d Minimum lot depth: 125 feet. The applicant’s proposal shows each lot has approximately 200 feet of depth. Yes <br />8e Minimum front yard setback: 25 feet on internal streets within the RPUD site. <br /> The applicant’s proposal shows the homes set back approximately 50 feet from the Ferndale Road in the front. Yes <br />8f Minimum side yard setback: ten feet along interior lot lines; 15 feet on lot lines along the <br />exterior of the RPUD site. The applicant’s proposal reflects 20-foot internal side setbacks, and 30-foot side setbacks on the external side. Yes <br />8g Rear yard setback: minimum of 40 feet or 20 percent of the depth of the lot, whichever is <br />less. The applicant’s proposal shows the homes are approximately 90 feet from rear (west) lot line. Yes <br />8h Building height: maximum of 30 feet. No house plans have been provided. However, the 30-foot height limitation is achievable. Yes <br />8i <br />All dwelling units… shall have a depth of at least 20 feet for at least 50 percent of their <br />width. All dwelling units… shall have a width of at least 20 feet for at least 50 percent of <br />their depth. <br />No house plans have been provided. However, the dimensional requirements are achievable. Yes <br />8j All dwellings shall have a permanent foundation in conformance with the state building <br />code. No house plans have been provided. However, the homes shall conform to the requirements for a permanent foundation. Yes <br />8k & 8l Relates to Accessory buildings None are proposed. Yes <br />8m Off-street parking shall be provided for at least two vehicles for each single-family <br />dwelling. The plans show this can be accomplished. Yes <br />11 <br />Private recreational area. Each RPUD development shall provide a minimum of 10% of <br />the gross project area in private recreational uses for project residents. Private <br />recreational area requirements are in addition to the standard park dedication <br />requirements. <br />The plans reflect individual, single-family lots and no common space for recreational purposes. No <br /> <br />52