My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
03-17-2025 - Agenda Packet Planning Commission - PC Packet
Orono
>
Planning Commission
>
2025
>
03-17-2025 - Agenda Packet Planning Commission - PC Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2026 10:57:21 AM
Creation date
3/18/2025 9:25:39 AM
Metadata
Fields
Template:
Administration
Admin Doc Type
Agenda Packet Planning Commission
Section
Planning Commission
Subject
PC Packet
Document Date
3/17/2025
Retention
After
Protection
Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FUTURE <br />BUILDING 3 <br />S-1 <br />FUTURE <br />BUILDING 4 <br />S-1 <br />FUTURE <br />BUILDING 5 <br />S-1 <br />BUILDING 2 <br />S-1 <br />BUILDING 1 <br />S-1 <br />BUILDING CODES <br />2020 MINNESOTA BUILDING CODE (2018 IBC BASE) <br />2020 MINNESOTA FIRE CODE (2018 IFC BASE) <br />2020 MINNESOTA ENERGY CONSERVATION CODE <br />2020 MINNESOTA MECHANICAL CODE <br />2020 MINNESOTA PLUMBING CODE <br />2020 NATIONAL ELECTRICAL CODE OSHA 1910 <br />2010 ADA STANDARDS <br />OCCUPANCY: <br />311.1 S-1 MODERATE-HAZARD STORAGE <br />(MOTOR VEHICLE RELATED OCCUPIANCIES) <br />CONSTRUCTION TYPE: <br />602.5 TYPE V-B, SPRINKLERED <br />GENERAL BUILDING HEIGHTS: <br />TABLE S-1 OCCUPANCY, TYPE V-B CONSTRUCTION <br />504.3 ALLOWABLE:60’, 2 STORIES <br /> ACTUAL: B1 / B2 24'-1”/ 33'-9”, 1 STORY <br />GENERAL BUILDING AREAS: <br />506.2 ALLOWABLE (1-STORY):36,000 SF <br />ACTUAL: PHASE I <br />• BUILDING 1 <br />• (40’x 240’)9,600 SF <br />• BUILDING 2 <br />• (40’x 260)10,400 SF <br />• (46’x 275’)12,650 SF <br /> 23,050 SF <br />FIRE SEPARATIONS <br />TABLE <br />508.4 REQUIRED SEPARATION OF OCCUPANCIES <br />S-1 to S-1 = NO RATING REQUIRED <br />FIRE-RESISTANCE RATING REQUIREMENT, TYPE V-B <br />TABLE <br />601 STRUCTURAL FRAME:0-HOUR <br />EXT BEARING WALLS:0-HOUR <br />INT BEARING WALLS:0-HOUR <br />NONBRG WALLS:FLOOR 0-HOUR <br />CONSTRUCTION:ROOF 0-HOUR <br />CONSTRUCTION:0-HOUR <br />602.5 TYPE V CONSTRUCTION: STRUCTURAL ELEMENTS, <br />EXTERIOR WALLS AND INTERIOR WALLS ARE OF <br />ANY MATERIALS PERMIITED BY THIS CODE. <br />MAXIMUM AREA OF EXTERIOR WALL OPENINGS <br />TABLE <br />705.8 X IS GREATER THAN 10' AND LESS THAN 30' <br />FIRE SEPARATION DISTANCE FOR S1 IS 0-HR <br />718.4.3 DRAFTSTOPPING IS NOT REQUIRED AS CONCEALED <br />SPACE IS FULLY SPRINKLED. <br />FINISHES: <br />TABLE <br />803.13 FIRE CLASSIFICATIONS FOR FINISHES <br />SPRINKLERED S <br />EXIT ENCL & EXIT PASSAGEWAYS C <br />CORRIDORS C <br />ROOMS and ENCLOSED SPACES C <br />FIRE PROTECTION SYSTEMS: <br />903.2.9 AUTOMATIC SPRINKLER SYSTEM TO BE PROVIDED IN <br />S-1 OCCUPANCIES WHEN FIRE AREA EXCEEDS 12,000 SF <br />OR AREA IS LOCATED MORE THAN THREE STORIES <br />ABOVE GRADE. <br />TABLE PORTABLE FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS <br />906.3(1)75’MAX TRAVEL DISTANCE TO AN EXTINQUISHER, 11,250 SF <br />MAXIMUM FLOOR AREA FOR EXTINQUISHER. <br />910.2.(2)SMOKE AND HEAT REMOVAL NOT REQUIRED WHEN PROTECTED <br />BY AN APPROVED AUTOMATIC SPRINKLER SYSTEM. <br />• SPRINKLERS ARE PROVIDED <br />MEANS OF EGRESS: <br />TABLE OCCUPANCY <br />1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT <br />STORAGE = 300 SF (GROSS)/OCCUPANT <br />• SEE CODE DIAGRAMS FOR OCCUPANCY COUNTS <br />1005.3.2 .15”/OCCUPANT FOR ALL OTHER MEANS OF EGRESS <br />• SEE CODE DIAGRAMS FOR EGRESS WIDTHS PROVIDED <br />TABLE COMMON PATH ALLOWABLE WITH ONE EXIT (SPRINKLERED) <br />1006.2.1 GROUP S = 75’ <br />• 1 EXITS PROVIDED PER LEVEL <br />TABLE 2 EXITS REQUIRED WHEN OCCUPANT LOADS EXCEED: <br />1010.1.1 MINIMUM CLEAR WIDTH OF DOOR TO BE 32” <br />1010.1.3 MAXIMUM PULL OR PUSH FORCE FOR EGRESS DOORS TO BE 5 POUNDS. <br />1010.1.5 THERE IS TO BE A LANDING EACH SIDE OF A DOOR. LANDING TO BE LEVEL <br />WITH A MAXIMUM SLOPE OF 2-PERCENT. <br />1010.1.6 LANDING WIDTH TO BE A MINIMUM EQUAL TO THE WIDTH OF THE DOOR. <br />1010.1.7 MAXIMUM ½-INCH THRESHOLD AT DOORS. <br />1013.1 EXIT SIGNS TO BE PROVIDED AT EXIT DOORS PER SECTION 1011.1 <br />TABLE S-1 OCCUPANCY SPRINKLERED -MAXIMUM TRAVEL DISTANCE: <br />1017.2 ALLOWABLE:250’-0” <br />ACTUAL:54’-0” <br />MEANS OF EGRESS ILLUMINATION <br />1008.2 MEANS OF EGRESS, INCLUDING EXIT DISCHARGE, TO BE ILLUMINATED AT ALL TIMES <br />THE BUILDING IS OCCUPIED. <br />1008.2.1 MEANS OF EGRESS ILLUMINATION LEVEL TO BE NOT LESS THAN 1 FC AT THE WALK <br />SURFACE. <br />1008.3.1 EMERGENCY POWER FOR ILLUMINATION <br />• IN THE EVENT O F A POWER SUPPLY FAILURE IN BUILDING REQUIRED TO HAVE <br />TWO OF MORE EXITS; EMERGENCY POWER TO ILLUMINATE THE FOLLOWING: INTERIOR <br />EXIT ACCESS STAIRWAY, INTERIOR AND EXTERIOR STAIRWAYS, EXIT PASSAGE WAYS, <br />EXTERIOR LANDINGS FOR EXIT DOORS <br />1008.3.4 EMERGENCY POWER SHALL PROVIDE POWER FOR A DURATION OF 90-MINUTE, <br />MINIMUM. <br />1009.1 ACCESSIBLE SPACES TO BE PROVIDE WITH NOT LESS THAN ONE ACCESSIBLE <br />MEANS OF EGRESS. WHERE MORE THAN ONE MEANS OF EGRESS IS PROVIDED, <br />NOT LESS THAN TWO ACCESSIBLE MEANS OF EGRESS SHALL BE PROVIDED. SEE <br />SECTION 1103.2.9 FOR AREAS NOT REQUIRED TO BE ACCESSIBLE. <br />EXIT SIGNS <br />1013.1 EXIT AND EXIT ACCESS DOORS TO BE MARKED WITH APPROVED EXIT SIGN <br />READILY VISIBLE FROM ANY DIRECTION OF TRAVEL. EXIT SIGN PLACEMENT TO BE <br />SUCH THAT NO POINT IN AN EXIT CORRIDOR OR PASSAGEWAY IS MORE THAN <br />100’OR THE VIEW DISTANCE LISTED FOR THE SIGN, WHICHEVER IS LESS. <br />1013.3 EXIT SIGNS TO BE INTERNALLY OR EXTERNALLY ILLUMINATED. <br />1013.5 INTERNALLY ILLUMINATED EXIT SIGNS: SIGN TO BE LISTED AND LABELED IN <br />ACCORDANCE WITH UL 924. BE ILLUMINATED AT ALL TIMES. <br />1013.6.2 EXIT SIGN ILLUMINATION TO HAVE INTENSITY OF NOT LESS THAN 5 FC (54 LUX) <br />1013.6.3 EXIT SIGN TO BE ILLUMINATED AT ALL TIMES AND ILLUMINATED FOR A MINIMUM <br />OF 90 MINUTES IN THE CASE OF A LOSS OF POWER. <br />ROOF ASSEMBLIES AND ROOFTOP STRUCTURES <br />TABLE <br />1505.1 MINIMUM ROOF COVERING CLASS FOR TYPE II B:CLASS C <br />763.559.9100 <br />www.vaaeng.com2300 Berkshire Lane N, Suite 200 <br />Plymouth, MN 55441 <br />VAA, LLC <br />DRAWING NO:PROJECT NO: <br />DRAWING TITLE: <br />CLIENT: <br />PROJECT: <br />SCALE: <br />FOR CONSTRUCTION <br />ISSUED <br />Date Plotted:AS NOTED <br />DATE: <br />DESIGNED: <br />DRAWN: <br />ISSUE/REVISIONDATENO. BY <br />CHECKED: APPROVED: <br />NOTICE: THE DESIGN SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL <br />DRAWINGS, DETAILS, DEVELOPMENTS, GRAPHICS AND MODELS THEREOF, ARE THE <br />EXCLUSIVE PROPERTY OF VAA, LLC, AND CAN'T BE COPIED, DUPLICATED, REPRODUCED <br />OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, NOR CAN ANY DERIVATIVE WORK <br />BE MADE UNLESS EXPRESSLY AUTHORIZED IN WRITING BY VAA, LLC. <br />COPYRIGHT VAA, LLC 2025 - ALL RIGHTS RESERVED. <br />TRAVIS R. BECK, 41400 <br />BUILDING 1 <br />3/3/2025 11:56:32 AMCL100 <br />CODE DIAGRAM SITE PLAN AND <br />CODE SUMMARY <br />ORONO GARAGE CONDOS <br />430 OLD CRYSTAL BAY RD <br />ORONO, MN 55356 <br />ROBERT L. PAGE <br />5840 CLUB VALLEY RD <br />SHOREWOOD, MN 55331 <br />240776 <br />03/03/25 <br />MGH <br />MGH/ DRM/ BCF <br />TRB TRB <br />1/16" = 1'-0"CL100 <br />SITE PLAN1 <br />CODE SUMMARY <br />NORTH <br />0 03/03/25 ISSUED FOR CONSTRUCTION MGH <br />Signature <br />Printed name <br />Date License Number <br />I hereby certify that this plan, specification, or report was <br />prepared by me or under my direct supervision and that <br />I am a duly Licensed Architect under the laws of the <br />State of Minnesota. <br />Architect <br />41400 <br />TRAVIS R. BECK, Architect, NCARB <br />03/03/2025 <br />AIA, NCARB <br />169
The URL can be used to link to this page
Your browser does not support the video tag.