Laserfiche WebLink
AREA LOCATION SITE LOCATION <br />SHEET INDEX <br />ORONO <br />MINNESOTA <br />ORONO <br />SITE LOCATION <br />ORONO GARAGE CONDOS -BUILDING 1 <br />ROBERT L. PAGE <br />ORONO, MN <br />ABBREVIATIONS <br />AB ANCHOR BOLT <br />AC AIR CONDITIONING <br />ACT ACOUSTICAL TILE <br />AFF ABOVE FINISHED FLOOR <br />AL ALUMINUM <br />ALT ALTERNATE <br />ANCH ANCHOR <br />ARCH ARCHITECTURAL <br />BD BOARD <br />BTWN BETWEEN <br />BLDG BUILDING <br />BM BEAM <br />BRG BEARING <br />BSMT BASEMENT <br />BOT BOTTOM <br />BTU BRITISH THERMAL UNIT <br />C/O CLOSED OPENING <br />CCTV CLOSED CIRCUIT TV <br />CFM CUBIC FEET/MINUTE <br />CJ CONTROL JOINT <br />CLG CEILING <br />CMU CONCRETE MASONRY UNIT <br />CO CLEAN OUT <br />COL COLUMN <br />CONC CONCRETE <br />CONN CONNECTION <br />CONST CONSTRUCTION <br />CONT CONTINUOUS <br />CONTR CONTRACTOR <br />CPT CARPET <br />CT CERAMIC TILE <br />CTR CENTER(ed) <br />CW COLD WATER <br />DEMO DEMOLISH <br />DEPT DEPARTMENT <br />DIA DIAMETER <br />DIM DIMENSION <br />DISP DISPENSER <br />DIV DIVISION <br />DN DOWN <br />DO DITTO <br />DR DOOR <br />EA EACH <br />EL ELEVATION <br />ELEC ELECTRIC(al) <br />EIFS EXT INSUL & FIN SYSTEM <br />EQ EQUAL <br />EQUIP EQUIPMENT <br />EW EACH WAY <br />EWC ELECTRIC WATER COOLER <br />EX EXPOSED <br />EXIST EXISTING <br />EXP EXPANSION <br />EXT EXTERIOR <br />FH FULL HEIGHT <br />FAB FABRICATE(ion)(or) <br />FD FLOOR DRAIN <br />FDN FOUNDATION <br />FE FIRE EXTINGUISHER <br />FFE FINISH FLOOR ELEVATION <br />FIN FINSH (ed) <br />FIX FIXTURE <br />FLR FLOOR <br />FT FOOT <br />FTG FOOTING <br />FUT FUTURE <br />GA GAUGE, GAGE <br />GB GRAB BAR <br />GFI GROUND FAULT INTERRUPT <br />GALV GALVANIZED <br />GL GLOSS, GLAZING <br />GPM GALLONS PER MINUTE <br />GYP BD GYPSUM BOARD <br />HB HOSE BIB <br />HC HOLLOW CORE <br />HDBD HEADBOARD <br />HDCP HANDICAPPED <br />HDWD HARDWOOD <br />HDWR HARDWARE <br />HM HOLLOW METAL <br />HORIZ HORIZONTAL (REBAR) <br />HT HEIGHT <br />HVAC HEAT/VENT & AIR COND <br />HW HOT WATER <br />HYD HYDRANT <br />ID INSIDE DIAMETER <br />IN INCH <br />INSUL INSULATION <br />INT INTERIOR <br />INV INVERT <br />ISOL ISOLATION JOINT <br />JAN JANITOR <br />JST JOIST <br />JT JOINT <br />LAV LAVATORY <br />LB POUND <br />MATL MATERIAL <br />MAX MAXIMUM <br />MECH MECHANICAL <br />MET/MTL METAL <br />MFR MANUFACTURER <br />MH MANHOLE <br />MIN MINIMUM, MINUTE <br />MISC MISCELLANEOUS <br />MO MASONRY OPENING <br />MR MOISTURE RESISTIVE <br />N/A NOT APPLICABLE <br />NIC NOT IN CONTRACT <br />NTS NOT TO SCALE <br />OC ON CENTER <br />OH OVERHEAD <br />OPNG OPENING <br />OPP OPPOSITE <br />ORD OVERFLOW ROOF DRAIN <br />PART PARTITION <br />PART BD PARTICAL BOARD <br />PBLG PLUMBING <br />PLF LBS PER LINEAR FOOT <br />PLAM PLASTIC LAMINATE <br />P PROPERTY LINE or PLATE <br />PLYWD PLYWOOD <br />PP POWER POLE <br />PR PAIR <br />PRV POWER ROOF VENT <br />PSF LBS PER SQUARE FOOT <br />PSI LBS PER SQUARE INCH <br />PT POINT <br />PTS PLYWOOD THIS SIDE <br />PVC POLYVINYL CHOLORIDE <br />QR QUARRY TILE <br />QTY QUANTITY <br />R RADIUS, RISER <br />RA RETURN AIR <br />RD ROOF DRAIN <br />REF REFERENCE <br />REFG REFRIGERATOR <br />REG REGISTER <br />REINF REINFORCE (ing)(ed) <br />REQD REQUIRED <br />RET RETURN <br />REV REVERSED <br />RM ROOM <br />RO ROUGH OPENING <br />ROW RIGHT-OF-WAY <br />RTU ROOF TOP UNIT <br />RV ROOF VENT <br />RWL RAIN WATER LEADER <br />SD SOAP DISPENSER <br />SECT SECTION <br />SF SQUARE FOOTAGE <br />SIM SIMILAR <br />SLNT SEALANT <br />SND SANITARY NAPKIN DISP <br />SNR SANITARY NAPKIN RECPT <br />SPEC SPECIFICATION(s) <br />SQ SQUARE <br />SS SERVICE SINK <br />STL STEEL <br />STRUCT STRUCTURE(al) <br />SYST SYSTEM <br />TB TOWEL BAR <br />TD TOWEL DISPENSER <br />TELE TELEPHONE <br />TEMP TEMPERATURE <br />TFE TOP OF FTG ELEV <br />THRES THRESHOLD <br />TPD TOILET PAPER DISPENSER <br />TRANSF TRANSFER <br />TV TELEVISION <br />TYP TYPICAL <br />UNO UNLESS NOTED OTHERWISE <br />UTL UTILITY <br />VCT VINYL COMPOSITION TILE <br />VAV VARIABLE AIR VOLUME <br />VERT(S) VERTICAL (REBAR) <br />VWC VINYL WALL COVERING <br />VRFY VERIFY <br />W/ WITH <br />W/O WITHOUT <br />WC WATER CLOSET <br />WD WOOD <br />WDW WINDOW <br />WP WATERPROOF(ing) <br />WR WATER RESISTIVE <br />WSCT WAINSCOT <br />WT WEIGHT <br />WWF WELDED WIRE FABRIC <br />L <br />DBL DOUBLE <br />DRAFTING SYMBOLS <br />A200 SHEET NUMBER <br />DISCIPLINE <br />COLUMN GRID <br />SECTION NUMBER <br />SHEET NUMBER <br />DETAIL NUMBER <br />SHEET NUMBER <br />SHEET NUMBER <br />ELEVATION NUMBER <br />INTERIOR ELEVATION NUMBER <br />SHEET NUMBER <br />ELEVATIONS <br />REVISION NUMBER <br />KEYNOTE <br />EXISTING SPOT ELEVATION <br />SPOT ELEVATION <br />WALL OR SURFACE MOUNTED FIRE EXTINGUISHER <br />WALL MOUNTED FIRE EXTINGUISHER CABINET <br />RECESSED FIRE EXTINGUISHER AND CABINET <br />ROOM NAME <br />ROOM NUMBER <br />DOOR NUMBER <br />EXISTING WALL, DOOR, FIXTURE, ETC. TO BE REMOVED <br />EXISTING WALL, DOOR, FIXTURE, ETC. TO REMAIN <br />NEW PARTITION <br />PARTITION OR WALL TYPE <br />CONTROL JOINT <br />A2101 <br />2 <br />1 <br />A101______________1 <br />A500 <br />GR <br />______________1 <br />A400 <br />______________1 <br />A201 <br />2 <br />G6XSROOM <br />100 <br />98'-10 1/2" <br />100'-0" <br />AHJ AUTHORITY HAVING JURISDICTION <br />L ANGLE <br />AHU AIR HANDLING UNIT <br />FDC <br />YD YARD <br />FIRE DEPARTMENT CONNECTION <br />UNOCC UNOCCUPIED <br />MEMB MEMBRANE <br />T/ TOP OF <br />B/ BOTTOM OF <br />LOC(S) LOCATION(s) <br />SCHED SCHEDULE <br />EF EACH FACE <br />IF INSIDE FACE <br />OF OUTSIDE FACE <br />ADDL ADDITIONAL <br />HR HOUR <br />GENERAL NOTES <br />1. DRAWINGS SHALL COVER THE FULL EXTENT OF THE PROJECT. <br />2. CONTRACTOR TO COORDINATE ALL WORK WITH ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, ELECTRICAL, SPECIFICATIONS, DRAWINGS <br />AND SUB-CONTRACTORS. <br />3. CONTRACTOR SHALL VISIT THE SITE, COMPARE DRAWINGS AND <br />SPECIFICATIONS, AND BE KNOWLEDGEABLE OF OTHER WORK BEING <br />PERFORMED. FAILURE OF CONTRACTOR TO VISIT THE SITE SHALL NOT <br />RELIEVE CONTRACTOR OF RESPONSIBILITY TO COMPLETE THE CONTRACT <br />WORK IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS WITHOUT <br />ADDITIONAL COST TO OWNER. <br />4. ALL DIMENSIONS ON ARCHITECTURAL DRAWINGS LOCATING STRUCTURAL <br />ELEMENTS ARE TO CENTERLINE OF STEEL COLUMNS AND STEEL BEAMS, <br />UNLESS NOTED OTHERWISE. <br />5. ALL DIMENSIONS LOCATING EXTERIOR WALL SYSTEMS ARE TO EXTERIOR <br />FINISH FACE OR TO INTERIOR FINISH FACE, UNLESS NOTED OTHERWISE. <br />6. ALL PLAN DIMENSIONS ARE TO FACE OF CONCRETE BLOCK OR GYPSUM BOARD <br />OR TOTAL WALL THICKNESS. SEE FINISH PLAN AND/ OR DETAILS FOR FINISH <br />MATERIALS. APPLIED MATERIALS SUCH AS CERAMIC TILE ARE NOT INCLUDED IN <br />TOTAL PARTITION THICKNESS. <br />7. ALL CHANGES IN FLOOR FINISHES SHALL OCCUR BENEATH DOORS UNLESS <br />NOTED OTHERWISE OR DETAILED OTHERWISE. <br />8. PROVIDE FIRE-TREATED WOOD BLOCKING AT ALL WALL HUNG ITEMS ON <br />GYPSUM BOARD PARTITIONS, INCLUDING ALL WALL MOUNTED DOOR STOPS. <br />9. VERIFY ALL DIMENSIONS BEFORE PROCEEDING WITH WORK. NOTIFY <br />ARCHITECT OF ANY ERRORS AND/ OR DISCREPANCY PRIOR TO PROCEEDING <br />WITH WORK. <br />10. DO NOT SCALE THE DRAWINGS FOR BUILDING PURPOSES. USE PLAN <br />INFORMATION, DIMENSIONS, SHOP DRAWINGS AND FIELD VERIFICATION FOR <br />ANY CONSTRUCTION. <br />MATERIALS <br />SHIM <br />WOOD BLOCKING <br />METAL <br />BOARD INSUL <br />BATT/BLANKET INSUL <br />PLASTER/GROUT <br />GYPSUM BOARD <br />PARTICAL BOARD <br />PLYWOOD <br />WOOD FINISH <br />STONE <br />BRICK <br />CMU (CONCRETE MASONRY UNIT) <br />CONCRETE <br />GRANULAR FILL <br />EARTH <br />FIN FLR <br />EL = 100'-0" <br />US-12US-12 OLD CRYSTAL BAY RD NWAYZATA BLVDWAYZATA BLVD <br />WILLOW DR NPROJECT TEAM <br />OWNER ROBERT L. PAGE <br />PHONE: 952-200-6384 <br />CONTACT: ROBERT PAGE <br />EMAIL: robertlouis.page@gmail.com <br />ARCHITECT:VAA, LLC <br />2300 BERKSHIRE LANE N, SUITE 200 <br />PLYMOUTH, MN 55441 <br />DIRECT: 763-577-9198 <br />FAX: 763-559-0378 <br />CONTACT: TRAVIS R. BECK, <br />EMAIL: tbeck@vaaeng.com <br />VAA, LLC <br />2300 BERKSHIRE LANE N, SUITE 200 <br />PLYMOUTH, MN 55441 <br />DIRECT: 763-577-9120 <br />FAX: 763-559-0378 <br />CONTACT: MARK MIELKE <br />EMAIL: mmielke@vaaeng.com <br />STRUCTURAL: <br />HAGSTROM ENGINEERING <br />219 6TH AVE E <br />ALEXANDRIA, MN 56308 <br />WORK: 320-759-0764 <br />CELL: 720-560-4942 <br />CONTACT: MATTHEW HAGSTROM <br />EMAIL: mhagstrom@hagstromeng.com <br />CIVIL: <br />STRUCTURAL <br />S001 <br />S101 <br />STRUCTURAL NOTES <br />FOUNDATION PLAN <br />ROOF FRAMING PLANS121 <br />S501 FOUNDATION DETAILS <br />S502 FRAMING DETAILS <br />CODE LIFE SAFETY <br />CL100 <br />CL101 <br />CODE DIAGRAM SITE PLAN AND CODE SUMMARY <br />FOUNDATION PLAN <br />ARCHITECTURAL <br />A101 <br />A110 <br />FLOOR AND ROOF PLANS <br />REFLECTED CEILING PLAN <br />EXTERIOR ELEVATIONSA201 <br />A220 BUILDING SECTIONS <br />A301 WALL SECTIONS <br />A601 WALL PARTITION TYPES, DOOR & FRAME ELEVATIONS, and SCHEDULES <br />CIVIL -HAGSTROM ENGINEERING <br />C1.0 <br />C2.0 <br />COVER SHEET <br />EXISTING SITE & DEMO <br />PROPOSED SITE PLANC3.0 <br />C3.1 PROPOSED UTILITY PLAN <br />C4.0 PRELIMINARY GRADING & EROSION CONTROL PLAN <br />C5.0 CONSTRUCTION DETAILS <br />C5.1 CONSTRUCTION DETAILS <br />C5.2 CONSTRUCTION DETAILS <br />G001 COVER SHEET <br />SHEET #SHEET DESCRIPTION <br />763.559.9100 <br />www.vaaeng.com2300 Berkshire Lane N, Suite 200 <br />Plymouth, MN 55441 <br />VAA, LLC <br />DRAWING NO:PROJECT NO: <br />DRAWING TITLE: <br />CLIENT: <br />PROJECT: <br />SCALE: <br />FOR CONSTRUCTION <br />ISSUED <br />Date Plotted:AS NOTED <br />DATE: <br />DESIGNED: <br />DRAWN: <br />ISSUE/REVISIONDATENO. BY <br />CHECKED: APPROVED: <br />NOTICE: THE DESIGN SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL <br />DRAWINGS, DETAILS, DEVELOPMENTS, GRAPHICS AND MODELS THEREOF, ARE THE <br />EXCLUSIVE PROPERTY OF VAA, LLC, AND CAN'T BE COPIED, DUPLICATED, REPRODUCED <br />OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, NOR CAN ANY DERIVATIVE WORK <br />BE MADE UNLESS EXPRESSLY AUTHORIZED IN WRITING BY VAA, LLC. <br />COPYRIGHT VAA, LLC 2025 - ALL RIGHTS RESERVED. <br />TRAVIS R. BECK, 41400 <br />BUILDING 1 <br />3/3/2025 11:56:30 AMG001 <br />COVER SHEET <br />ORONO GARAGE CONDOS <br />430 OLD CRYSTAL BAY RD <br />ORONO, MN 55356 <br />ROBERT L. PAGE <br />5840 CLUB VALLEY RD <br />SHOREWOOD, MN 55331 <br />240776 <br />03/03/25 <br />MGH <br />MGH/ DRM/ BCF <br />TRB TRB <br />0 03/03/25 ISSUED FOR CONSTRUCTION MGH <br />HIT AR HI AR HI , NCARB <br />Signature <br />Printed name <br />Date License Number <br />I hereby certify that this plan, specification, or report was <br />prepared by me or under my direct supervision and that <br />I am a duly Licensed Architect under the laws of the <br />State of Minnesota. <br />Architect <br />41400 <br />TRAVIS R. BECK, Architect, NCARB <br />03/03/2025 <br />AIA, NCARB <br />168