My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1978-06-07 Septic System Design
Orono
>
Property Files
>
Street Address
>
C
>
Colin Drive
>
2165 Colin Drive - 03-117-23-21-0017
>
Septic
>
1978-06-07 Septic System Design
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 3:14:14 PM
Creation date
2/20/2025 2:24:15 PM
Metadata
Fields
Template:
x Address Old
House Number
2165
Street Name
Colin
Street Type
Drive
Address
2165 Colin Drive
PIN
0311723210017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E. The inlet baffle or sanitary tee shall extend at least six inches but not <br />more than 20 percent of the total liquid depth below the liquid surface and <br />at least one inch above the crown of the inlet sewer. <br />F. The outlet baffle or sanitary tee and the baffles or sanitary tees between <br />compartments shall extend below the liquid surface a distance equal to 40 <br />percent of the liquid depth except that the penetration of the indicated <br />baffles or sanitary tees for horizontal cylindrical tanks shall be 35 <br />percent of the total liquid depth. They also shall extend above the liquid <br />surface as required in 0 above. In no case shall they extend less than <br />six inches above the liquid surface. <br />G. There shall be at least one inch between the underside of the top of the tank <br />and the highest point of the inlet and outlet devices. <br />H. The inlet invert shall be not less than three inches above the outlet <br />invert. <br />1. The inlet and outlet shall be located opposite each other along the axis of <br />maximum dimension. The horizontal distance between the nearest points of <br />the inlet and outlet devices shall be at least four feet. <br />J. Sewage tanks shall be set back the following distance from the features given <br />below: <br />Feature Minimum Setbank Uistancts (feet) <br />Water Supply Well and Bur ed — 56 <br />Water Suction Pipe <br />3uried Pipe Distributing <br />10' <br />Water Under Pressure <br />Eui ldings <br />10' ?.O <br />Property Lines <br />10' <br />The Ordinary High Water Mark of: <br />Natural Environment Lakes <br />1SID'* <br />and Rivers <br />Recreational Development <br />750* <br />Lakes and Rivers <br />General Development Lakes <br />500* <br />and Streams <br />Wild River <br />1501* <br />Scenic River <br />1001* <br />Designated Tributaries of <br />751* <br />Wild, Scenic, and Recreational <br />Rivers <br />Wetlands <br />751 <br />PgiFFC00eo <br />*Required for new development and where practicable, for existing developments. <br />